Use of profile analysis for the measurement of organ dimensions

Michael K. O'Connor, William M. Oswald, Manuel L. Brown, Patrick Sequeira Kamath, Sidney F. Phillips

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

We have developed a method for measurement of organ dimesnion based on the use of the full width half maximum (FWHM) of profiles taken through an organ. In vitro studies were performed using a large rectangular lucite box filled with water. Five circular lucite phantoms with internal diameters of 1.4-10.2 cm and 1 elliptical phantom with dimensions 9.6x4.0 cm were filled with 99mTc-pertechnetate at various concentrations. Phantoms were imaged on a gamma camera at a depth of 5-25 cm in water and the FWHM calculated from horizontal profiles taken across the cylinders. The FWHM showed no variation with 99mTc concentration in the same cylinder. Phantom profiles were deconvolved with a system line spread function measured under similar conditions of scatter and depth. The correction factor to convert the deconvolved profile FWHM to true diameter was independent of cylinder depth and diameter over a range of FWHM 3-10 cm and depth 5-25 cm. The mean value for the correction factor was 1.23±0.04 for circular phantoms and 1.14±0.02 for the elliptical phantom. This technique should allow an objective and reproducible estimate of organ dimensions from planar images that is relatively independent of the depth and size of an organ.

Original languageEnglish (US)
Pages (from-to)562-564
Number of pages3
JournalEuropean Journal Of Nuclear Medicine
Volume14
Issue number11
DOIs
StatePublished - Nov 1988

Fingerprint

Polymethyl Methacrylate
Sodium Pertechnetate Tc 99m
Gamma Cameras
Organ Size
Water
In Vitro Techniques

Keywords

  • Deconvolution
  • Full width half maximum
  • Organ size

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Use of profile analysis for the measurement of organ dimensions. / O'Connor, Michael K.; Oswald, William M.; Brown, Manuel L.; Kamath, Patrick Sequeira; Phillips, Sidney F.

In: European Journal Of Nuclear Medicine, Vol. 14, No. 11, 11.1988, p. 562-564.

Research output: Contribution to journalArticle

O'Connor, Michael K. ; Oswald, William M. ; Brown, Manuel L. ; Kamath, Patrick Sequeira ; Phillips, Sidney F. / Use of profile analysis for the measurement of organ dimensions. In: European Journal Of Nuclear Medicine. 1988 ; Vol. 14, No. 11. pp. 562-564.
@article{af79a1bea4d14d9aab1b144f763daa1e,
title = "Use of profile analysis for the measurement of organ dimensions",
abstract = "We have developed a method for measurement of organ dimesnion based on the use of the full width half maximum (FWHM) of profiles taken through an organ. In vitro studies were performed using a large rectangular lucite box filled with water. Five circular lucite phantoms with internal diameters of 1.4-10.2 cm and 1 elliptical phantom with dimensions 9.6x4.0 cm were filled with 99mTc-pertechnetate at various concentrations. Phantoms were imaged on a gamma camera at a depth of 5-25 cm in water and the FWHM calculated from horizontal profiles taken across the cylinders. The FWHM showed no variation with 99mTc concentration in the same cylinder. Phantom profiles were deconvolved with a system line spread function measured under similar conditions of scatter and depth. The correction factor to convert the deconvolved profile FWHM to true diameter was independent of cylinder depth and diameter over a range of FWHM 3-10 cm and depth 5-25 cm. The mean value for the correction factor was 1.23±0.04 for circular phantoms and 1.14±0.02 for the elliptical phantom. This technique should allow an objective and reproducible estimate of organ dimensions from planar images that is relatively independent of the depth and size of an organ.",
keywords = "Deconvolution, Full width half maximum, Organ size",
author = "O'Connor, {Michael K.} and Oswald, {William M.} and Brown, {Manuel L.} and Kamath, {Patrick Sequeira} and Phillips, {Sidney F.}",
year = "1988",
month = "11",
doi = "10.1007/BF00286777",
language = "English (US)",
volume = "14",
pages = "562--564",
journal = "European Journal of Nuclear Medicine and Molecular Imaging",
issn = "1619-7070",
publisher = "Springer Verlag",
number = "11",

}

TY - JOUR

T1 - Use of profile analysis for the measurement of organ dimensions

AU - O'Connor, Michael K.

AU - Oswald, William M.

AU - Brown, Manuel L.

AU - Kamath, Patrick Sequeira

AU - Phillips, Sidney F.

PY - 1988/11

Y1 - 1988/11

N2 - We have developed a method for measurement of organ dimesnion based on the use of the full width half maximum (FWHM) of profiles taken through an organ. In vitro studies were performed using a large rectangular lucite box filled with water. Five circular lucite phantoms with internal diameters of 1.4-10.2 cm and 1 elliptical phantom with dimensions 9.6x4.0 cm were filled with 99mTc-pertechnetate at various concentrations. Phantoms were imaged on a gamma camera at a depth of 5-25 cm in water and the FWHM calculated from horizontal profiles taken across the cylinders. The FWHM showed no variation with 99mTc concentration in the same cylinder. Phantom profiles were deconvolved with a system line spread function measured under similar conditions of scatter and depth. The correction factor to convert the deconvolved profile FWHM to true diameter was independent of cylinder depth and diameter over a range of FWHM 3-10 cm and depth 5-25 cm. The mean value for the correction factor was 1.23±0.04 for circular phantoms and 1.14±0.02 for the elliptical phantom. This technique should allow an objective and reproducible estimate of organ dimensions from planar images that is relatively independent of the depth and size of an organ.

AB - We have developed a method for measurement of organ dimesnion based on the use of the full width half maximum (FWHM) of profiles taken through an organ. In vitro studies were performed using a large rectangular lucite box filled with water. Five circular lucite phantoms with internal diameters of 1.4-10.2 cm and 1 elliptical phantom with dimensions 9.6x4.0 cm were filled with 99mTc-pertechnetate at various concentrations. Phantoms were imaged on a gamma camera at a depth of 5-25 cm in water and the FWHM calculated from horizontal profiles taken across the cylinders. The FWHM showed no variation with 99mTc concentration in the same cylinder. Phantom profiles were deconvolved with a system line spread function measured under similar conditions of scatter and depth. The correction factor to convert the deconvolved profile FWHM to true diameter was independent of cylinder depth and diameter over a range of FWHM 3-10 cm and depth 5-25 cm. The mean value for the correction factor was 1.23±0.04 for circular phantoms and 1.14±0.02 for the elliptical phantom. This technique should allow an objective and reproducible estimate of organ dimensions from planar images that is relatively independent of the depth and size of an organ.

KW - Deconvolution

KW - Full width half maximum

KW - Organ size

UR - http://www.scopus.com/inward/record.url?scp=0023760432&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0023760432&partnerID=8YFLogxK

U2 - 10.1007/BF00286777

DO - 10.1007/BF00286777

M3 - Article

C2 - 2850187

AN - SCOPUS:0023760432

VL - 14

SP - 562

EP - 564

JO - European Journal of Nuclear Medicine and Molecular Imaging

JF - European Journal of Nuclear Medicine and Molecular Imaging

SN - 1619-7070

IS - 11

ER -