Two generations of the St. Jude Medical ATG coronary connector systems for coronary artery anastomoses in coronary artery bypass grafting

Friedrich S. Eckstein, Luis F. Bonilla, Hartzell Schaff, Lars Englberger, Stephan Windecker, Paul Hindrichs, Thierry P. Carrel

Research output: Contribution to journalArticlepeer-review

13 Scopus citations

Abstract

Background. In the past, coronary anastomoses have been performed using running and, occasionally, interrupted non-resorbable sutures. Recently, special interest has developed in mechanical anastomotic devices to facilitate minimal invasive techniques or limited access surgery. The experience with two series of patients undergoing coronary artery bypass grafting (CABG) using the St. Jude Medical ATG coronary connector systems (investigational stainless steel device, not yet commercially available) for vein-to-coronary artery anastomoses is reported here. Methods. Between November 2000 and April 2002, we evaluated two generations of distal coronary connector systems in 19 patients who were scheduled for multivessel CABG. One vein graft-to-coronary artery anastomosis per patient was performed with a stainless steel mechanical connector, in an ongoing investigational study. Although these two generations of the St. Jude Medical ATG coronary connectors have the same underlying construction, somewhat cumbersome loading of the first-generation system led to simplification of the second-generation system, which is currently evaluated. Results. With the first generation of distal connector, hemostasis was instantaneous in all cases, and all anastomoses were patent at the end of the procedure. However, retrograde flow to the native coronary artery was restricted in 1 patient. The connector was removed, and the anastomosis was performed with a running suture at the same site. Three-month angiography or magnetic resonance imaging angiography was available in 11 patients with 10 patent connector grafts. With the second-generation connectors one of five had to be removed because of leakage, and the anastomosis could be sutured at the same site. The other four connector anastomoses were patent and hemostatic at the end of the procedure. Conclusions. The St. Jude Medical ATG coronary connector system is an effective device for sutureless vein graft to coronary artery anastomoses in CABG. The second-generation system presents a further development eliminating some drawbacks of the first generation such as cumbersome, time-consuming loading as well as suitability for smaller coronary arteries. These connectors allow construction of geometrically round anastomoses and theoretically may also be suitable for sequential anastomoses. After tremendous research and development efforts, an optimized mechanical connection system for small vessel anastomoses has been introduced into clinical investigation. This represents a major step in the era of sutureless vascular connections in cardiac surgery.

Original languageEnglish (US)
Pages (from-to)1363-1367
Number of pages5
JournalAnnals of Thoracic Surgery
Volume74
Issue number4
DOIs
StatePublished - Oct 1 2002

ASJC Scopus subject areas

  • Surgery
  • Pulmonary and Respiratory Medicine
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Two generations of the St. Jude Medical ATG coronary connector systems for coronary artery anastomoses in coronary artery bypass grafting'. Together they form a unique fingerprint.

Cite this