The 'impact' of force filtering cut-off frequency on the peak knee abduction moment during landing: Artefact or 'artifiction'

Benjamin D. Roewer, Kevin R. Ford, Gregory D. Myer, Timothy E. Hewett

Research output: Contribution to journalArticlepeer-review

35 Scopus citations

Abstract

Background Joint moments computed using inverse dynamic techniques are important estimators of net joint loads. Joints moments computed from marker position and ground reaction force data filtered using different cut-off frequencies may capture changes in moment magnitudes at a single joint that exceed normal physiological response. Peak external knee abduction moment (KAM) generated during landing (ie, the drop vertical jump, DVJ) predicts anterior cruciate ligament injury risk using marker and force data filtered at different cut-off frequencies. The purpose of the current investigation was to determine the effects of using the same low cut-off frequencies versus different cut-off frequencies on joint moment magnitudes to evaluate if artificial smoothing attenuates actual resultant joint loads related to injury risk. Methods Twenty-two female, high school volleyball players performed three maximum DVJs in a laboratory setting. The average peak KAM was computed for each knee using marker and force data filtered with the same low cut-off frequencies and different cut-off frequencies. Results Peak KAMs were significantly larger using different cut-off frequencies. The order of athletes ranked based on the magnitude of their peak KAMs did not significantly change across all filtering cut-off frequencies. Conclusions The magnitude of peak KAM may differ when the same low or different higher cut-off frequencies are used to filter marker and ground reaction forces (GRF) data collected using standard motion capture equipment. It is not clear to what extent the decrease in peak KAM reported when the same low cutoff frequencies were used was solely due to attenuation of the GRF signal.

Original languageEnglish (US)
Pages (from-to)464-468
Number of pages5
JournalBritish journal of sports medicine
Volume48
Issue number6
DOIs
StatePublished - Mar 2014

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine
  • Physical Therapy, Sports Therapy and Rehabilitation

Fingerprint

Dive into the research topics of 'The 'impact' of force filtering cut-off frequency on the peak knee abduction moment during landing: Artefact or 'artifiction''. Together they form a unique fingerprint.

Cite this