TY - JOUR
T1 - 99mTc-tilmanocept versus 99mTc-sulfur colloid in lymphoscintigraphy
T2 - Sentinel lymph node identification and patient-reported pain
AU - Murphy, Brittany L.
AU - Woodwick, Allison R.
AU - Murphy, Katie M.
AU - Chandler, Kimberly J.
AU - Johnson, Geoffrey B.
AU - Hunt, Christopher H.
AU - Peller, Patrick
AU - Jakub, James W.
AU - Homb, Andrew C.
N1 - Publisher Copyright:
COPYRIGHT © 2019 by the Society of Nuclear Medicine and Molecular Imaging.
PY - 2019/12/1
Y1 - 2019/12/1
N2 - Lymphoscintigraphy plays a vital role in sentinel lymph node (SLN) identification in oncologic breast surgery. The effectiveness of SLN localization and the degree of patient pain were compared between filtered 99mTc-sulfur colloid (99mTc-SC) and 99mTc-tilmanocept. Methods: A retrospective review of patients undergoing lymphoscintigraphy for breast cancer using 99mTc-SC (June 1, 2010, to December 31, 2011) or 99mTc-tilmanocept (June 1, 2013, to January 31, 2014) was performed. SLN appearance time and uptake, SLN pathology, proportion of positive SLNs removed, and pain scores were compared for each radiopharmaceutical using the χ2 test, Fisher exact test, and unequal variance t test, as appropriate. Results: In total, 76 patients, with 86 evaluated axillae, underwent lymphoscintigraphy: 29 with 99mTc-SC and 47 with 99mTc-tilmanocept. The mean SLN appearance time was 11.0 min for 99mTc-SC and 19.3 min for 99mTc-tilmanocept (P 5 0.003). There was no difference in the mean transit uptake percentage: 2.2% for 99mTc-SC and 1.9% for 99mTc-tilmanocept (P 5 0.55). 99mTc-tilmanocept identified a greater proportion of intraoperative blue nodes than did 99mTc-SC (P 5 0.03). There was no significant difference between 99mTc-SC and 99mTc-tilmanocept in the number of SLNs removed, number of patients with positive SLNs, or pain score. Conclusion: 99mTc-SC use in lymphoscintigraphy is an acceptable alternative to 99mTc-tilmanocept for SLN detection in breast cancer, on the basis of the similarity in intraoperative SLN identification and pain scores.
AB - Lymphoscintigraphy plays a vital role in sentinel lymph node (SLN) identification in oncologic breast surgery. The effectiveness of SLN localization and the degree of patient pain were compared between filtered 99mTc-sulfur colloid (99mTc-SC) and 99mTc-tilmanocept. Methods: A retrospective review of patients undergoing lymphoscintigraphy for breast cancer using 99mTc-SC (June 1, 2010, to December 31, 2011) or 99mTc-tilmanocept (June 1, 2013, to January 31, 2014) was performed. SLN appearance time and uptake, SLN pathology, proportion of positive SLNs removed, and pain scores were compared for each radiopharmaceutical using the χ2 test, Fisher exact test, and unequal variance t test, as appropriate. Results: In total, 76 patients, with 86 evaluated axillae, underwent lymphoscintigraphy: 29 with 99mTc-SC and 47 with 99mTc-tilmanocept. The mean SLN appearance time was 11.0 min for 99mTc-SC and 19.3 min for 99mTc-tilmanocept (P 5 0.003). There was no difference in the mean transit uptake percentage: 2.2% for 99mTc-SC and 1.9% for 99mTc-tilmanocept (P 5 0.55). 99mTc-tilmanocept identified a greater proportion of intraoperative blue nodes than did 99mTc-SC (P 5 0.03). There was no significant difference between 99mTc-SC and 99mTc-tilmanocept in the number of SLNs removed, number of patients with positive SLNs, or pain score. Conclusion: 99mTc-SC use in lymphoscintigraphy is an acceptable alternative to 99mTc-tilmanocept for SLN detection in breast cancer, on the basis of the similarity in intraoperative SLN identification and pain scores.
KW - Lymphoscintigraphy
KW - Lymphoseek
KW - Sulfur colloid
KW - Tilmanocept
UR - http://www.scopus.com/inward/record.url?scp=85075956915&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85075956915&partnerID=8YFLogxK
U2 - 10.2967/JNMT.118.225342
DO - 10.2967/JNMT.118.225342
M3 - Article
C2 - 31019032
AN - SCOPUS:85075956915
SN - 0091-4916
VL - 47
SP - 300
EP - 304
JO - Journal of Nuclear Medicine Technology
JF - Journal of Nuclear Medicine Technology
IS - 4
ER -