Spiral CT: Decreased spatial resolution in vivo due to broadening of section-sensitivity profile

J. A. Brink, Jay Heiken, D. M. Balfe, S. S. Sagel, J. DiCroce, M. W. Vannier

Research output: Contribution to journalArticle

103 Citations (Scopus)

Abstract

Comparable conventional and spiral computed tomographic (CT) scanning protocols for transaxial (n = 30) and multiplanar reformation (MPR) (n = 15) imaging were performed to image the adrenal gland and the upper pole of the right kidney in the same patient, without use of intravenously administered contrast media. The sharpness of soft-tissue-fat interfaces oriented in the transverse (xy) and longitudinal (z) directions was measured as the maximum and full width at half maximum (FWHM) of the edge attenuation profile first derivative. Edge sharpness was qualitatively assessed by three blinded reviewers, who used a four-point scale. In vivo transaxial CT studies showed that the conventional scans produced slightly sharper edges than the spiral scans (mean difference of spiral and conventional FWHM = 0.30 mm [P < .05] [in z direction] and 0.21 mm [P < .05] [in xy direction]). In vivo MPR studies showed that interfaces in the xy plane were significantly less sharp with spiral scanning, whereas interfaces in the z direction were equivalent for conventional and spiral scanning (mean difference of spiral and conventional FWHM = 0.03 mm [P > .05] [in z direction] and 1.19 mm [P < .05] [in xy direction]). Significant respiratory misregistration was present on seven of 15 (47%) conventional MPR scans and on no spiral MPR scans.

Original languageEnglish (US)
Pages (from-to)469-474
Number of pages6
JournalRadiology
Volume185
Issue number2
DOIs
StatePublished - Jan 1 1992
Externally publishedYes

Fingerprint

Adrenal Glands
Contrast Media
Fats
Kidney
Direction compound

Keywords

  • Adrenal gland, CT
  • Computed tomography (CT), image quality
  • Computed tomography (CT), technology
  • Diaphragm, CT
  • Kidney, CT

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Spiral CT : Decreased spatial resolution in vivo due to broadening of section-sensitivity profile. / Brink, J. A.; Heiken, Jay; Balfe, D. M.; Sagel, S. S.; DiCroce, J.; Vannier, M. W.

In: Radiology, Vol. 185, No. 2, 01.01.1992, p. 469-474.

Research output: Contribution to journalArticle

Brink, J. A. ; Heiken, Jay ; Balfe, D. M. ; Sagel, S. S. ; DiCroce, J. ; Vannier, M. W. / Spiral CT : Decreased spatial resolution in vivo due to broadening of section-sensitivity profile. In: Radiology. 1992 ; Vol. 185, No. 2. pp. 469-474.
@article{d7f168713b6f4a9883a53b9d9bb6eb7d,
title = "Spiral CT: Decreased spatial resolution in vivo due to broadening of section-sensitivity profile",
abstract = "Comparable conventional and spiral computed tomographic (CT) scanning protocols for transaxial (n = 30) and multiplanar reformation (MPR) (n = 15) imaging were performed to image the adrenal gland and the upper pole of the right kidney in the same patient, without use of intravenously administered contrast media. The sharpness of soft-tissue-fat interfaces oriented in the transverse (xy) and longitudinal (z) directions was measured as the maximum and full width at half maximum (FWHM) of the edge attenuation profile first derivative. Edge sharpness was qualitatively assessed by three blinded reviewers, who used a four-point scale. In vivo transaxial CT studies showed that the conventional scans produced slightly sharper edges than the spiral scans (mean difference of spiral and conventional FWHM = 0.30 mm [P < .05] [in z direction] and 0.21 mm [P < .05] [in xy direction]). In vivo MPR studies showed that interfaces in the xy plane were significantly less sharp with spiral scanning, whereas interfaces in the z direction were equivalent for conventional and spiral scanning (mean difference of spiral and conventional FWHM = 0.03 mm [P > .05] [in z direction] and 1.19 mm [P < .05] [in xy direction]). Significant respiratory misregistration was present on seven of 15 (47{\%}) conventional MPR scans and on no spiral MPR scans.",
keywords = "Adrenal gland, CT, Computed tomography (CT), image quality, Computed tomography (CT), technology, Diaphragm, CT, Kidney, CT",
author = "Brink, {J. A.} and Jay Heiken and Balfe, {D. M.} and Sagel, {S. S.} and J. DiCroce and Vannier, {M. W.}",
year = "1992",
month = "1",
day = "1",
doi = "10.1148/radiology.185.2.1410356",
language = "English (US)",
volume = "185",
pages = "469--474",
journal = "Radiology",
issn = "0033-8419",
publisher = "Radiological Society of North America Inc.",
number = "2",

}

TY - JOUR

T1 - Spiral CT

T2 - Decreased spatial resolution in vivo due to broadening of section-sensitivity profile

AU - Brink, J. A.

AU - Heiken, Jay

AU - Balfe, D. M.

AU - Sagel, S. S.

AU - DiCroce, J.

AU - Vannier, M. W.

PY - 1992/1/1

Y1 - 1992/1/1

N2 - Comparable conventional and spiral computed tomographic (CT) scanning protocols for transaxial (n = 30) and multiplanar reformation (MPR) (n = 15) imaging were performed to image the adrenal gland and the upper pole of the right kidney in the same patient, without use of intravenously administered contrast media. The sharpness of soft-tissue-fat interfaces oriented in the transverse (xy) and longitudinal (z) directions was measured as the maximum and full width at half maximum (FWHM) of the edge attenuation profile first derivative. Edge sharpness was qualitatively assessed by three blinded reviewers, who used a four-point scale. In vivo transaxial CT studies showed that the conventional scans produced slightly sharper edges than the spiral scans (mean difference of spiral and conventional FWHM = 0.30 mm [P < .05] [in z direction] and 0.21 mm [P < .05] [in xy direction]). In vivo MPR studies showed that interfaces in the xy plane were significantly less sharp with spiral scanning, whereas interfaces in the z direction were equivalent for conventional and spiral scanning (mean difference of spiral and conventional FWHM = 0.03 mm [P > .05] [in z direction] and 1.19 mm [P < .05] [in xy direction]). Significant respiratory misregistration was present on seven of 15 (47%) conventional MPR scans and on no spiral MPR scans.

AB - Comparable conventional and spiral computed tomographic (CT) scanning protocols for transaxial (n = 30) and multiplanar reformation (MPR) (n = 15) imaging were performed to image the adrenal gland and the upper pole of the right kidney in the same patient, without use of intravenously administered contrast media. The sharpness of soft-tissue-fat interfaces oriented in the transverse (xy) and longitudinal (z) directions was measured as the maximum and full width at half maximum (FWHM) of the edge attenuation profile first derivative. Edge sharpness was qualitatively assessed by three blinded reviewers, who used a four-point scale. In vivo transaxial CT studies showed that the conventional scans produced slightly sharper edges than the spiral scans (mean difference of spiral and conventional FWHM = 0.30 mm [P < .05] [in z direction] and 0.21 mm [P < .05] [in xy direction]). In vivo MPR studies showed that interfaces in the xy plane were significantly less sharp with spiral scanning, whereas interfaces in the z direction were equivalent for conventional and spiral scanning (mean difference of spiral and conventional FWHM = 0.03 mm [P > .05] [in z direction] and 1.19 mm [P < .05] [in xy direction]). Significant respiratory misregistration was present on seven of 15 (47%) conventional MPR scans and on no spiral MPR scans.

KW - Adrenal gland, CT

KW - Computed tomography (CT), image quality

KW - Computed tomography (CT), technology

KW - Diaphragm, CT

KW - Kidney, CT

UR - http://www.scopus.com/inward/record.url?scp=0026661923&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0026661923&partnerID=8YFLogxK

U2 - 10.1148/radiology.185.2.1410356

DO - 10.1148/radiology.185.2.1410356

M3 - Article

C2 - 1410356

AN - SCOPUS:0026661923

VL - 185

SP - 469

EP - 474

JO - Radiology

JF - Radiology

SN - 0033-8419

IS - 2

ER -