Robot-assisted delayed extraction of retained Lasso catheter combined with mitral valve repair and arrhythmia ablation

Sameh M. Said, Rakesh M. Suri, Sorin V. Pislaru, Richard C. Daly, Roger L. Click, Maria D. Fritock, Paul Andrew Friedman

Research output: Contribution to journalArticle

1 Citation (Scopus)
Original languageEnglish (US)
Pages (from-to)238-240
Number of pages3
JournalHeartRhythm Case Reports
Volume1
Issue number4
DOIs
StatePublished - Jul 1 2015

Fingerprint

Robotics
Mitral Valve
Atrial Fibrillation
Cardiac Arrhythmias
Catheters
alachlor

Keywords

  • Ablation
  • Atrial fibrillation
  • Catheter
  • Mitral
  • Robotic

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

Robot-assisted delayed extraction of retained Lasso catheter combined with mitral valve repair and arrhythmia ablation. / Said, Sameh M.; Suri, Rakesh M.; Pislaru, Sorin V.; Daly, Richard C.; Click, Roger L.; Fritock, Maria D.; Friedman, Paul Andrew.

In: HeartRhythm Case Reports, Vol. 1, No. 4, 01.07.2015, p. 238-240.

Research output: Contribution to journalArticle

Said, Sameh M. ; Suri, Rakesh M. ; Pislaru, Sorin V. ; Daly, Richard C. ; Click, Roger L. ; Fritock, Maria D. ; Friedman, Paul Andrew. / Robot-assisted delayed extraction of retained Lasso catheter combined with mitral valve repair and arrhythmia ablation. In: HeartRhythm Case Reports. 2015 ; Vol. 1, No. 4. pp. 238-240.
@article{e0b7bd6ebf3043aca3a280046a59a37a,
title = "Robot-assisted delayed extraction of retained Lasso catheter combined with mitral valve repair and arrhythmia ablation",
keywords = "Ablation, Atrial fibrillation, Catheter, Mitral, Robotic",
author = "Said, {Sameh M.} and Suri, {Rakesh M.} and Pislaru, {Sorin V.} and Daly, {Richard C.} and Click, {Roger L.} and Fritock, {Maria D.} and Friedman, {Paul Andrew}",
year = "2015",
month = "7",
day = "1",
doi = "10.1016/j.hrcr.2015.03.013",
language = "English (US)",
volume = "1",
pages = "238--240",
journal = "HeartRhythm Case Reports",
issn = "2214-0271",
publisher = "Elsevier Inc.",
number = "4",

}

TY - JOUR

T1 - Robot-assisted delayed extraction of retained Lasso catheter combined with mitral valve repair and arrhythmia ablation

AU - Said, Sameh M.

AU - Suri, Rakesh M.

AU - Pislaru, Sorin V.

AU - Daly, Richard C.

AU - Click, Roger L.

AU - Fritock, Maria D.

AU - Friedman, Paul Andrew

PY - 2015/7/1

Y1 - 2015/7/1

KW - Ablation

KW - Atrial fibrillation

KW - Catheter

KW - Mitral

KW - Robotic

UR - http://www.scopus.com/inward/record.url?scp=84949544772&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84949544772&partnerID=8YFLogxK

U2 - 10.1016/j.hrcr.2015.03.013

DO - 10.1016/j.hrcr.2015.03.013

M3 - Article

AN - SCOPUS:84949544772

VL - 1

SP - 238

EP - 240

JO - HeartRhythm Case Reports

JF - HeartRhythm Case Reports

SN - 2214-0271

IS - 4

ER -