Abstract
Objective: Percutaneous aortic valve implantation within native valve calcium has progressed to clinical use despite the absence of data proving equivalence to complete surgical excision and prosthetic valve replacement. A novel self-expanding sutureless bovine pericardial prosthesis (Sorin Perceval) derived from a proven stented valve has been successfully used in humans recently through an open transaortic approach. We sought to develop a minimally invasive technique for native aortic valve excision and sutureless prosthetic aortic valve replacement using robot assistance. Methods: The da Vinci S-HD system was used to open and suspend the pericardium anterior to the phrenic nerve in cadavers. A transthoracic cross-clamp was placed across the midascending aorta, following which a transverse aortotomy was made. The native aortic valve cusps were excised, and annular calcium was removed with robotic instruments. After placement of three guide sutures, the Perceval self-expanding pericardial prosthesis mounted on a flexible delivery system was inserted through a working port and lowered into the aortic annulus. Results: Successful implantation of all valves was possible using a 3-cm right second intercostal space working port, along with two additional 1-cm instrument ports. A standard transverse aortotomy was sufficient for examination/debridement of the native aortic valve cusps, sizing of the annulus, and deployment of the nitinol-stented, bovine pericardial prosthesis. Delivery, seating, and stability of the device were easily confirmed above and below the aortic valve annulus using the robotic camera. Conclusions: Complete excision of diseased native aortic valve cusps with robot assistance facilitates accurate and reproducible aortic valve replacement using a novel self-expanding sutureless version of a proven bovine pericardial prosthesis. This approach is comparable to the current surgical gold standard and is ready for clinical use as an alternative to percutaneous aortic valve implantation.
Original language | English (US) |
---|---|
Pages (from-to) | 419-423 |
Number of pages | 5 |
Journal | Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery |
Volume | 5 |
Issue number | 6 |
DOIs | |
State | Published - Nov 2010 |
Keywords
- Aortic valve
- Minimally invasive
- percutaneous
- Self-expanding
- Sutureless
ASJC Scopus subject areas
- Surgery
- Pulmonary and Respiratory Medicine
- Cardiology and Cardiovascular Medicine