Abstract
Detecting cancerous lesions is a major clinical application in emission tomography. In previous work, we have studied penalized maximum-likelihood (PML) image reconstruction for the detection task and proposed a method to design a shift-invariant quadratic penalty function to maximize detectability of a lesion at a known location in a two dimensional image. Here we extend the regularization design to maximize detectability of lesions at unknown locations in fully 3D PET. We used a multiview channelized Hotelling observer (mvCHO) to assess the lesion detectability in 3D images to mimic the condition where a human observer examines three orthogonal views of a 3D image for lesion detection. We derived simplified theoretical expressions that allow fast prediction of the detectability of a 3D lesion. The theoretical results were used to design the regularization in PML reconstruction to improve lesion detectability. We conducted computer-based Monte Carlo simulations to compare the optimized penalty with the conventional penalty for detecting lesions of various sizes. Only true coincidence events were simulated. Lesion detectability was also assessed by two human observers, whose performances agree well with that of the mvCHO. Both the numerical observer and human observer results showed a statistically significant improvement in lesion detection by using the proposed penalty function compared to using the conventional penalty function.
Original language | English (US) |
---|---|
Pages (from-to) | 403-419 |
Number of pages | 17 |
Journal | Physics in medicine and biology |
Volume | 59 |
Issue number | 2 |
DOIs | |
State | Published - Jan 20 2014 |
Externally published | Yes |
Fingerprint
ASJC Scopus subject areas
- Radiological and Ultrasound Technology
- Radiology Nuclear Medicine and imaging
Cite this
Regularization design in penalized maximum-likelihood image reconstruction for lesion detection in 3D PET. / Yang, Li; Zhou, Jian; Ferrero, Andrea; Badawi, Ramsey D.; Qi, Jinyi.
In: Physics in medicine and biology, Vol. 59, No. 2, 20.01.2014, p. 403-419.Research output: Contribution to journal › Article
}
TY - JOUR
T1 - Regularization design in penalized maximum-likelihood image reconstruction for lesion detection in 3D PET
AU - Yang, Li
AU - Zhou, Jian
AU - Ferrero, Andrea
AU - Badawi, Ramsey D.
AU - Qi, Jinyi
PY - 2014/1/20
Y1 - 2014/1/20
N2 - Detecting cancerous lesions is a major clinical application in emission tomography. In previous work, we have studied penalized maximum-likelihood (PML) image reconstruction for the detection task and proposed a method to design a shift-invariant quadratic penalty function to maximize detectability of a lesion at a known location in a two dimensional image. Here we extend the regularization design to maximize detectability of lesions at unknown locations in fully 3D PET. We used a multiview channelized Hotelling observer (mvCHO) to assess the lesion detectability in 3D images to mimic the condition where a human observer examines three orthogonal views of a 3D image for lesion detection. We derived simplified theoretical expressions that allow fast prediction of the detectability of a 3D lesion. The theoretical results were used to design the regularization in PML reconstruction to improve lesion detectability. We conducted computer-based Monte Carlo simulations to compare the optimized penalty with the conventional penalty for detecting lesions of various sizes. Only true coincidence events were simulated. Lesion detectability was also assessed by two human observers, whose performances agree well with that of the mvCHO. Both the numerical observer and human observer results showed a statistically significant improvement in lesion detection by using the proposed penalty function compared to using the conventional penalty function.
AB - Detecting cancerous lesions is a major clinical application in emission tomography. In previous work, we have studied penalized maximum-likelihood (PML) image reconstruction for the detection task and proposed a method to design a shift-invariant quadratic penalty function to maximize detectability of a lesion at a known location in a two dimensional image. Here we extend the regularization design to maximize detectability of lesions at unknown locations in fully 3D PET. We used a multiview channelized Hotelling observer (mvCHO) to assess the lesion detectability in 3D images to mimic the condition where a human observer examines three orthogonal views of a 3D image for lesion detection. We derived simplified theoretical expressions that allow fast prediction of the detectability of a 3D lesion. The theoretical results were used to design the regularization in PML reconstruction to improve lesion detectability. We conducted computer-based Monte Carlo simulations to compare the optimized penalty with the conventional penalty for detecting lesions of various sizes. Only true coincidence events were simulated. Lesion detectability was also assessed by two human observers, whose performances agree well with that of the mvCHO. Both the numerical observer and human observer results showed a statistically significant improvement in lesion detection by using the proposed penalty function compared to using the conventional penalty function.
UR - http://www.scopus.com/inward/record.url?scp=84896354249&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84896354249&partnerID=8YFLogxK
U2 - 10.1088/0031-9155/59/2/403
DO - 10.1088/0031-9155/59/2/403
M3 - Article
C2 - 24351981
AN - SCOPUS:84896354249
VL - 59
SP - 403
EP - 419
JO - Physics in Medicine and Biology
JF - Physics in Medicine and Biology
SN - 0031-9155
IS - 2
ER -