Pulse transmission coefficient

A novel nonhyperemic parameter for assessing the physiological significance of coronary artery stenoses

David Brosh, Stuart T. Higano, Marvin J. Slepian, Hylton I. Miller, Morton J. Kern, Ryan J. Lennon, David Holmes, Amir Lerman

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

OBJECTIVES: We sought to test the hypothesis that the pulse transmission coefficient (PTC) can serve as a nonhyperemic physiologic marker for the severity of coronary artery stenosis in humans. BACKGROUND: Coronary lesions may impair the transmission of pressure waves across a stenosis, potentially acting as a low-pass filter. The PTC is a novel nonhyperemic parameter that calculates the transmission of high-frequency components of the pressure signal through a stenosis. Thus, it may reflect the severity of the coronary artery stenosis. This study was designed to examine the correlation between PTC and fractional flow reserve (FFR) in patients with coronary artery disease. METHODS: Pressure signals were obtained by pressure guidewire in 56 lesions (49 patients) in the nonhyperemic state and were analyzed with a new algorithm that identifies the high-frequency components in the pressure signal. The PTC was calculated as the ratio between the distal and proximal high-frequency components of the pressure waveform across the lesion. The FFR measurements were assessed with intracoronary adenosine. RESULTS: There was a significant correlation between PTC and FFR (r = 0.81, p < 0.001). By using a receiver operating characteristic analysis, we identified a PTC < 0.60 (sensitivity 100%, specificity 98%) to be the optimal cutoff value for predicting an FFR < 0.75. CONCLUSIONS: Pulse transmission coefficient is a novel nonhyperemic parameter for the physiologic assessment of coronary artery stenoses. It correlates significantly with FFR and may predict an FFR < 0.75 with high accuracy. Pulse transmission coefficient may be useful as an adjunct measurement to FFR, especially in patients with microcirculatory disease and impaired maximal hyperemia.

Original languageEnglish (US)
Pages (from-to)1012-1019
Number of pages8
JournalJournal of the American College of Cardiology
Volume39
Issue number6
DOIs
StatePublished - Mar 20 2002

Fingerprint

Coronary Stenosis
Pressure
Pathologic Constriction
Hyperemia
ROC Curve
Adenosine
Coronary Artery Disease
Sensitivity and Specificity

ASJC Scopus subject areas

  • Nursing(all)

Cite this

Pulse transmission coefficient : A novel nonhyperemic parameter for assessing the physiological significance of coronary artery stenoses. / Brosh, David; Higano, Stuart T.; Slepian, Marvin J.; Miller, Hylton I.; Kern, Morton J.; Lennon, Ryan J.; Holmes, David; Lerman, Amir.

In: Journal of the American College of Cardiology, Vol. 39, No. 6, 20.03.2002, p. 1012-1019.

Research output: Contribution to journalArticle

Brosh, David ; Higano, Stuart T. ; Slepian, Marvin J. ; Miller, Hylton I. ; Kern, Morton J. ; Lennon, Ryan J. ; Holmes, David ; Lerman, Amir. / Pulse transmission coefficient : A novel nonhyperemic parameter for assessing the physiological significance of coronary artery stenoses. In: Journal of the American College of Cardiology. 2002 ; Vol. 39, No. 6. pp. 1012-1019.
@article{0adc7646e8c84f5e8731c91e5c406042,
title = "Pulse transmission coefficient: A novel nonhyperemic parameter for assessing the physiological significance of coronary artery stenoses",
abstract = "OBJECTIVES: We sought to test the hypothesis that the pulse transmission coefficient (PTC) can serve as a nonhyperemic physiologic marker for the severity of coronary artery stenosis in humans. BACKGROUND: Coronary lesions may impair the transmission of pressure waves across a stenosis, potentially acting as a low-pass filter. The PTC is a novel nonhyperemic parameter that calculates the transmission of high-frequency components of the pressure signal through a stenosis. Thus, it may reflect the severity of the coronary artery stenosis. This study was designed to examine the correlation between PTC and fractional flow reserve (FFR) in patients with coronary artery disease. METHODS: Pressure signals were obtained by pressure guidewire in 56 lesions (49 patients) in the nonhyperemic state and were analyzed with a new algorithm that identifies the high-frequency components in the pressure signal. The PTC was calculated as the ratio between the distal and proximal high-frequency components of the pressure waveform across the lesion. The FFR measurements were assessed with intracoronary adenosine. RESULTS: There was a significant correlation between PTC and FFR (r = 0.81, p < 0.001). By using a receiver operating characteristic analysis, we identified a PTC < 0.60 (sensitivity 100{\%}, specificity 98{\%}) to be the optimal cutoff value for predicting an FFR < 0.75. CONCLUSIONS: Pulse transmission coefficient is a novel nonhyperemic parameter for the physiologic assessment of coronary artery stenoses. It correlates significantly with FFR and may predict an FFR < 0.75 with high accuracy. Pulse transmission coefficient may be useful as an adjunct measurement to FFR, especially in patients with microcirculatory disease and impaired maximal hyperemia.",
author = "David Brosh and Higano, {Stuart T.} and Slepian, {Marvin J.} and Miller, {Hylton I.} and Kern, {Morton J.} and Lennon, {Ryan J.} and David Holmes and Amir Lerman",
year = "2002",
month = "3",
day = "20",
doi = "10.1016/S0735-1097(02)01725-4",
language = "English (US)",
volume = "39",
pages = "1012--1019",
journal = "Journal of the American College of Cardiology",
issn = "0735-1097",
publisher = "Elsevier USA",
number = "6",

}

TY - JOUR

T1 - Pulse transmission coefficient

T2 - A novel nonhyperemic parameter for assessing the physiological significance of coronary artery stenoses

AU - Brosh, David

AU - Higano, Stuart T.

AU - Slepian, Marvin J.

AU - Miller, Hylton I.

AU - Kern, Morton J.

AU - Lennon, Ryan J.

AU - Holmes, David

AU - Lerman, Amir

PY - 2002/3/20

Y1 - 2002/3/20

N2 - OBJECTIVES: We sought to test the hypothesis that the pulse transmission coefficient (PTC) can serve as a nonhyperemic physiologic marker for the severity of coronary artery stenosis in humans. BACKGROUND: Coronary lesions may impair the transmission of pressure waves across a stenosis, potentially acting as a low-pass filter. The PTC is a novel nonhyperemic parameter that calculates the transmission of high-frequency components of the pressure signal through a stenosis. Thus, it may reflect the severity of the coronary artery stenosis. This study was designed to examine the correlation between PTC and fractional flow reserve (FFR) in patients with coronary artery disease. METHODS: Pressure signals were obtained by pressure guidewire in 56 lesions (49 patients) in the nonhyperemic state and were analyzed with a new algorithm that identifies the high-frequency components in the pressure signal. The PTC was calculated as the ratio between the distal and proximal high-frequency components of the pressure waveform across the lesion. The FFR measurements were assessed with intracoronary adenosine. RESULTS: There was a significant correlation between PTC and FFR (r = 0.81, p < 0.001). By using a receiver operating characteristic analysis, we identified a PTC < 0.60 (sensitivity 100%, specificity 98%) to be the optimal cutoff value for predicting an FFR < 0.75. CONCLUSIONS: Pulse transmission coefficient is a novel nonhyperemic parameter for the physiologic assessment of coronary artery stenoses. It correlates significantly with FFR and may predict an FFR < 0.75 with high accuracy. Pulse transmission coefficient may be useful as an adjunct measurement to FFR, especially in patients with microcirculatory disease and impaired maximal hyperemia.

AB - OBJECTIVES: We sought to test the hypothesis that the pulse transmission coefficient (PTC) can serve as a nonhyperemic physiologic marker for the severity of coronary artery stenosis in humans. BACKGROUND: Coronary lesions may impair the transmission of pressure waves across a stenosis, potentially acting as a low-pass filter. The PTC is a novel nonhyperemic parameter that calculates the transmission of high-frequency components of the pressure signal through a stenosis. Thus, it may reflect the severity of the coronary artery stenosis. This study was designed to examine the correlation between PTC and fractional flow reserve (FFR) in patients with coronary artery disease. METHODS: Pressure signals were obtained by pressure guidewire in 56 lesions (49 patients) in the nonhyperemic state and were analyzed with a new algorithm that identifies the high-frequency components in the pressure signal. The PTC was calculated as the ratio between the distal and proximal high-frequency components of the pressure waveform across the lesion. The FFR measurements were assessed with intracoronary adenosine. RESULTS: There was a significant correlation between PTC and FFR (r = 0.81, p < 0.001). By using a receiver operating characteristic analysis, we identified a PTC < 0.60 (sensitivity 100%, specificity 98%) to be the optimal cutoff value for predicting an FFR < 0.75. CONCLUSIONS: Pulse transmission coefficient is a novel nonhyperemic parameter for the physiologic assessment of coronary artery stenoses. It correlates significantly with FFR and may predict an FFR < 0.75 with high accuracy. Pulse transmission coefficient may be useful as an adjunct measurement to FFR, especially in patients with microcirculatory disease and impaired maximal hyperemia.

UR - http://www.scopus.com/inward/record.url?scp=0037139312&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0037139312&partnerID=8YFLogxK

U2 - 10.1016/S0735-1097(02)01725-4

DO - 10.1016/S0735-1097(02)01725-4

M3 - Article

VL - 39

SP - 1012

EP - 1019

JO - Journal of the American College of Cardiology

JF - Journal of the American College of Cardiology

SN - 0735-1097

IS - 6

ER -