Method for the measurement of friction between tendon and pulley

S. Uchiyama, J. H. Coert, L. Berglund, Peter C Amadio, K. N. An

Research output: Contribution to journalArticle

114 Citations (Scopus)

Abstract

An experimental system was developed that allows direct measurement of friction at the tendon-pulley interface, and the results were interpreted by use of a theoretial model for friction of a cable around a fixed pulley. Validation experiments wre conducted with a nylon cable around a nylon rod. One end of the cable was connected to an actuator via a load cell, and the other end was connected to a 4.9 N load via a similar load cell. The cable was passed around the nylon rod and then pulled toward the actuator. Tests were performed at five different arcs of contact. The friction forces, as measured by the difference between two load transducers, were compared with those determined for a theoretical model and were used for calculation of the friction coefficient. The measurement system then was used to study the friction force between the flexor digitorum profundus tendon and the A2 pulley on nine fresh frozen index digits. The method allows us to measure the direct interaction between the tendon and pulley and could be used to evaluate and compare procedures for tendon-pulley repair and reconstruction, as well as for the study of tendon-pulley friction in various pathological conditions.

Original languageEnglish (US)
Pages (from-to)83-89
Number of pages7
JournalJournal of Orthopaedic Research
Volume13
Issue number1
DOIs
StatePublished - 1995

Fingerprint

Friction
Tendons
Nylons
Transducers
varespladib methyl
Theoretical Models

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine

Cite this

Method for the measurement of friction between tendon and pulley. / Uchiyama, S.; Coert, J. H.; Berglund, L.; Amadio, Peter C; An, K. N.

In: Journal of Orthopaedic Research, Vol. 13, No. 1, 1995, p. 83-89.

Research output: Contribution to journalArticle

Uchiyama, S. ; Coert, J. H. ; Berglund, L. ; Amadio, Peter C ; An, K. N. / Method for the measurement of friction between tendon and pulley. In: Journal of Orthopaedic Research. 1995 ; Vol. 13, No. 1. pp. 83-89.
@article{0a4c0b0b0ee442f09082c4616d00106c,
title = "Method for the measurement of friction between tendon and pulley",
abstract = "An experimental system was developed that allows direct measurement of friction at the tendon-pulley interface, and the results were interpreted by use of a theoretial model for friction of a cable around a fixed pulley. Validation experiments wre conducted with a nylon cable around a nylon rod. One end of the cable was connected to an actuator via a load cell, and the other end was connected to a 4.9 N load via a similar load cell. The cable was passed around the nylon rod and then pulled toward the actuator. Tests were performed at five different arcs of contact. The friction forces, as measured by the difference between two load transducers, were compared with those determined for a theoretical model and were used for calculation of the friction coefficient. The measurement system then was used to study the friction force between the flexor digitorum profundus tendon and the A2 pulley on nine fresh frozen index digits. The method allows us to measure the direct interaction between the tendon and pulley and could be used to evaluate and compare procedures for tendon-pulley repair and reconstruction, as well as for the study of tendon-pulley friction in various pathological conditions.",
author = "S. Uchiyama and Coert, {J. H.} and L. Berglund and Amadio, {Peter C} and An, {K. N.}",
year = "1995",
doi = "10.1002/jor.1100130113",
language = "English (US)",
volume = "13",
pages = "83--89",
journal = "Journal of Orthopaedic Research",
issn = "0736-0266",
publisher = "John Wiley and Sons Inc.",
number = "1",

}

TY - JOUR

T1 - Method for the measurement of friction between tendon and pulley

AU - Uchiyama, S.

AU - Coert, J. H.

AU - Berglund, L.

AU - Amadio, Peter C

AU - An, K. N.

PY - 1995

Y1 - 1995

N2 - An experimental system was developed that allows direct measurement of friction at the tendon-pulley interface, and the results were interpreted by use of a theoretial model for friction of a cable around a fixed pulley. Validation experiments wre conducted with a nylon cable around a nylon rod. One end of the cable was connected to an actuator via a load cell, and the other end was connected to a 4.9 N load via a similar load cell. The cable was passed around the nylon rod and then pulled toward the actuator. Tests were performed at five different arcs of contact. The friction forces, as measured by the difference between two load transducers, were compared with those determined for a theoretical model and were used for calculation of the friction coefficient. The measurement system then was used to study the friction force between the flexor digitorum profundus tendon and the A2 pulley on nine fresh frozen index digits. The method allows us to measure the direct interaction between the tendon and pulley and could be used to evaluate and compare procedures for tendon-pulley repair and reconstruction, as well as for the study of tendon-pulley friction in various pathological conditions.

AB - An experimental system was developed that allows direct measurement of friction at the tendon-pulley interface, and the results were interpreted by use of a theoretial model for friction of a cable around a fixed pulley. Validation experiments wre conducted with a nylon cable around a nylon rod. One end of the cable was connected to an actuator via a load cell, and the other end was connected to a 4.9 N load via a similar load cell. The cable was passed around the nylon rod and then pulled toward the actuator. Tests were performed at five different arcs of contact. The friction forces, as measured by the difference between two load transducers, were compared with those determined for a theoretical model and were used for calculation of the friction coefficient. The measurement system then was used to study the friction force between the flexor digitorum profundus tendon and the A2 pulley on nine fresh frozen index digits. The method allows us to measure the direct interaction between the tendon and pulley and could be used to evaluate and compare procedures for tendon-pulley repair and reconstruction, as well as for the study of tendon-pulley friction in various pathological conditions.

UR - http://www.scopus.com/inward/record.url?scp=0028931853&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028931853&partnerID=8YFLogxK

U2 - 10.1002/jor.1100130113

DO - 10.1002/jor.1100130113

M3 - Article

VL - 13

SP - 83

EP - 89

JO - Journal of Orthopaedic Research

JF - Journal of Orthopaedic Research

SN - 0736-0266

IS - 1

ER -