Interictal spike analysis of high-density eeg in patients with partial epilepsy

Gang Wang, Gregory Alan Worrell, Lin Yang, Christopher Wilke, Bin He

Research output: Contribution to journalArticle

42 Citations (Scopus)

Abstract

Objective: The aim of this study is to investigate the use of interictal spikes to localize epileptogenic brain from noninvasive scalp EEG recordings in patients with medically intractable epilepsy. Methods: Source reconstructions were performed using a high density electrode montage and a low density electrode montage by means of a distributed source modeling method. The source of interictal spike activity was localized using both a realistic geometry boundary element method (BEM) head model and 3-shell spherical head model. Results: In the analysis of 7 patients, the high density electrode montage was found to provide results more consistent with the suspected region of epileptogenic brain identified for surgical resection using intracranial EEG recordings and structural MRI lesions, as compared to the spatial low density electrode montage used in routine clinical practice. Furthermore, the realistic geometry BEM head model provided better source localization. Conclusions: Our results indicate the merits of using high density scalp EEG recordings and realistic geometry head modeling for source localization of interictal spikes in patients with partial epilepsy. Significance: The present results suggest further improvement of source localization accuracy of epileptogenic brain from interictal EEG recorded using high density scalp electrode montage and realistic geometry head models.

Original languageEnglish (US)
Pages (from-to)1098-1105
Number of pages8
JournalClinical Neurophysiology
Volume122
Issue number6
DOIs
StatePublished - Jun 2011

Fingerprint

Partial Epilepsy
Electrodes
Head
Scalp
Insulator Elements
Electroencephalography
Brain

Keywords

  • Boundary element method
  • EEG source localization
  • Interictal spike
  • Localization error
  • Partial epilepsy

ASJC Scopus subject areas

  • Clinical Neurology
  • Neurology
  • Physiology (medical)
  • Sensory Systems

Cite this

Interictal spike analysis of high-density eeg in patients with partial epilepsy. / Wang, Gang; Worrell, Gregory Alan; Yang, Lin; Wilke, Christopher; He, Bin.

In: Clinical Neurophysiology, Vol. 122, No. 6, 06.2011, p. 1098-1105.

Research output: Contribution to journalArticle

Wang, Gang ; Worrell, Gregory Alan ; Yang, Lin ; Wilke, Christopher ; He, Bin. / Interictal spike analysis of high-density eeg in patients with partial epilepsy. In: Clinical Neurophysiology. 2011 ; Vol. 122, No. 6. pp. 1098-1105.
@article{1e1db948ed5043e0832cbffcea88aebb,
title = "Interictal spike analysis of high-density eeg in patients with partial epilepsy",
abstract = "Objective: The aim of this study is to investigate the use of interictal spikes to localize epileptogenic brain from noninvasive scalp EEG recordings in patients with medically intractable epilepsy. Methods: Source reconstructions were performed using a high density electrode montage and a low density electrode montage by means of a distributed source modeling method. The source of interictal spike activity was localized using both a realistic geometry boundary element method (BEM) head model and 3-shell spherical head model. Results: In the analysis of 7 patients, the high density electrode montage was found to provide results more consistent with the suspected region of epileptogenic brain identified for surgical resection using intracranial EEG recordings and structural MRI lesions, as compared to the spatial low density electrode montage used in routine clinical practice. Furthermore, the realistic geometry BEM head model provided better source localization. Conclusions: Our results indicate the merits of using high density scalp EEG recordings and realistic geometry head modeling for source localization of interictal spikes in patients with partial epilepsy. Significance: The present results suggest further improvement of source localization accuracy of epileptogenic brain from interictal EEG recorded using high density scalp electrode montage and realistic geometry head models.",
keywords = "Boundary element method, EEG source localization, Interictal spike, Localization error, Partial epilepsy",
author = "Gang Wang and Worrell, {Gregory Alan} and Lin Yang and Christopher Wilke and Bin He",
year = "2011",
month = "6",
doi = "10.1016/j.clinph.2010.10.043",
language = "English (US)",
volume = "122",
pages = "1098--1105",
journal = "Clinical Neurophysiology",
issn = "1388-2457",
publisher = "Elsevier Ireland Ltd",
number = "6",

}

TY - JOUR

T1 - Interictal spike analysis of high-density eeg in patients with partial epilepsy

AU - Wang, Gang

AU - Worrell, Gregory Alan

AU - Yang, Lin

AU - Wilke, Christopher

AU - He, Bin

PY - 2011/6

Y1 - 2011/6

N2 - Objective: The aim of this study is to investigate the use of interictal spikes to localize epileptogenic brain from noninvasive scalp EEG recordings in patients with medically intractable epilepsy. Methods: Source reconstructions were performed using a high density electrode montage and a low density electrode montage by means of a distributed source modeling method. The source of interictal spike activity was localized using both a realistic geometry boundary element method (BEM) head model and 3-shell spherical head model. Results: In the analysis of 7 patients, the high density electrode montage was found to provide results more consistent with the suspected region of epileptogenic brain identified for surgical resection using intracranial EEG recordings and structural MRI lesions, as compared to the spatial low density electrode montage used in routine clinical practice. Furthermore, the realistic geometry BEM head model provided better source localization. Conclusions: Our results indicate the merits of using high density scalp EEG recordings and realistic geometry head modeling for source localization of interictal spikes in patients with partial epilepsy. Significance: The present results suggest further improvement of source localization accuracy of epileptogenic brain from interictal EEG recorded using high density scalp electrode montage and realistic geometry head models.

AB - Objective: The aim of this study is to investigate the use of interictal spikes to localize epileptogenic brain from noninvasive scalp EEG recordings in patients with medically intractable epilepsy. Methods: Source reconstructions were performed using a high density electrode montage and a low density electrode montage by means of a distributed source modeling method. The source of interictal spike activity was localized using both a realistic geometry boundary element method (BEM) head model and 3-shell spherical head model. Results: In the analysis of 7 patients, the high density electrode montage was found to provide results more consistent with the suspected region of epileptogenic brain identified for surgical resection using intracranial EEG recordings and structural MRI lesions, as compared to the spatial low density electrode montage used in routine clinical practice. Furthermore, the realistic geometry BEM head model provided better source localization. Conclusions: Our results indicate the merits of using high density scalp EEG recordings and realistic geometry head modeling for source localization of interictal spikes in patients with partial epilepsy. Significance: The present results suggest further improvement of source localization accuracy of epileptogenic brain from interictal EEG recorded using high density scalp electrode montage and realistic geometry head models.

KW - Boundary element method

KW - EEG source localization

KW - Interictal spike

KW - Localization error

KW - Partial epilepsy

UR - http://www.scopus.com/inward/record.url?scp=79956367451&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79956367451&partnerID=8YFLogxK

U2 - 10.1016/j.clinph.2010.10.043

DO - 10.1016/j.clinph.2010.10.043

M3 - Article

VL - 122

SP - 1098

EP - 1105

JO - Clinical Neurophysiology

JF - Clinical Neurophysiology

SN - 1388-2457

IS - 6

ER -