In vivo comparison of radiation exposure of dual-energy CT versus low-dose ct versus standard ct for imaging urinary calculi

Maria A. Jepperson, Joseph G. Cernigliaro, El Sayed H. Ibrahim, Richard L. Morin, William E. Haley, David D. Thiel

Research output: Contribution to journalArticlepeer-review

39 Scopus citations

Abstract

Purpose: Dual-energy computed tomography (DECT) is an emerging imaging modality with the unique capability of determining urinary stone composition. This study compares radiation exposure of DECT, standard single-energy CT (SECT), and low-dose renal stone protocol single-energy CT (LDSECT) for the evaluation of nephrolithiasis in a single in vivo patient cohort. Materials and Methods: Following institutional review board (IRB) approval, we retrospectively reviewed 200 consecutive DECT examinations performed on patients with suspected urolithiasis over a 6-month period. Of these, 35 patients had undergone examination with our LDSECT protocol, and 30 patients had undergone examination of the abdomen and pelvis with our SECT imaging protocol within 2 years of the DECT examination. The CT dose index volume (CTDIvol) was used to compare radiation exposure between scans. Image quality was objectively evaluated by comparing image noise. Statistical evaluation was performed using a Student's t-test. Results: DECT performed at 80/140kVp and 100/140kVp did not produce a significant difference in radiation exposure compared with LDSECT (p=0.09 and 0.18, respectively). DECT performed at 80/140kVp and 100/140kVp produced an average 40% and 31%, respectively, reduction in radiation exposure compared with SECT (p<0.001). For patients imaged with the 100/140kVp protocol, average values for images noise were higher in the LDSECT images compared with DECT images (p<0.001) and there was no significant difference in image noise between DECT and SECT images in the same patient (p=0.88). Patients imaged with the 80/140kVp protocol had equivocal image noise compared with LDSECT images (p=0.44), however, DECT images had greater noise compared with SECT images in the same patient (p<0.001). Of the 75 patients included in the study, stone material was available for 16; DECT analysis correctly predicted stone composition in 15/16 patients (93%). Conclusion: DECT provides knowledge of stone composition in addition to the anatomic information provided by LDSECT/SECT without increasing patient radiation exposure and with minimal impact on image noise.

Original languageEnglish (US)
Pages (from-to)141-146
Number of pages6
JournalJournal of endourology
Volume29
Issue number2
DOIs
StatePublished - Feb 1 2015

ASJC Scopus subject areas

  • Urology

Fingerprint

Dive into the research topics of 'In vivo comparison of radiation exposure of dual-energy CT versus low-dose ct versus standard ct for imaging urinary calculi'. Together they form a unique fingerprint.

Cite this