Hardware and software approaches to multi-modality imaging

Thomas L. Klausen, Flemming Andersen, Brad Kemp

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

There has been a longstanding interest in multi-modality imaging especially in nuclear medicine where the lack of structural information in Single Photon Emission Computed Tomography (SPECT) images and Positron Emission Tomography (PET) images makes it difficult to assess the precise location of tissue with metabolic uptake, whereas Magnetic Resonance Imaging (MRI) and Computed Tomography (CT) can provide great anatomical details. The hardware approach to image fusion is to use hybrid scanners (SPECT/CT, PET/CT or PET/MRI). With this approach image fusion is simplified because the two scans are acquired sequentially (or simultaneously with PET/MR) which minimizes any motion. Hardware hybrid scanner designs are facing many challenges such as the conversion of CT numbers to attenuation coefficients, artefacts due to the presence of high Zeff material, and respiratory motion. Software approaches to multimodality imaging emerged in the late1980's and were using semi-automated or automatic approaches by registering surface contours or surface points. The big step towards fully automated software based image fusion appeared when the registration method started to use a direct analysis of image data to achieve an optimal registration often using iterative approaches to maximize mutual information between images. Software based image fusion is complex and involves many decisions regarding fusion tools, reconstruction techniques and final image presentation of fused data.

Original languageEnglish (US)
Pages (from-to)169-174
Number of pages6
JournalCurrent Medical Imaging Reviews
Volume7
Issue number3
StatePublished - Aug 2011

Fingerprint

Positron-Emission Tomography
Software
Tomography
Magnetic Resonance Imaging
Nuclear Medicine
Single-Photon Emission-Computed Tomography
Artifacts
Positron Emission Tomography Computed Tomography
Single Photon Emission Computed Tomography Computed Tomography

Keywords

  • ET/CT
  • Hybrid scanner
  • Multi modality
  • PET/MRI
  • SPECT/CT

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Klausen, T. L., Andersen, F., & Kemp, B. (2011). Hardware and software approaches to multi-modality imaging. Current Medical Imaging Reviews, 7(3), 169-174.

Hardware and software approaches to multi-modality imaging. / Klausen, Thomas L.; Andersen, Flemming; Kemp, Brad.

In: Current Medical Imaging Reviews, Vol. 7, No. 3, 08.2011, p. 169-174.

Research output: Contribution to journalArticle

Klausen, TL, Andersen, F & Kemp, B 2011, 'Hardware and software approaches to multi-modality imaging', Current Medical Imaging Reviews, vol. 7, no. 3, pp. 169-174.
Klausen, Thomas L. ; Andersen, Flemming ; Kemp, Brad. / Hardware and software approaches to multi-modality imaging. In: Current Medical Imaging Reviews. 2011 ; Vol. 7, No. 3. pp. 169-174.
@article{92257312ef164c40ae16f37dfca8ac97,
title = "Hardware and software approaches to multi-modality imaging",
abstract = "There has been a longstanding interest in multi-modality imaging especially in nuclear medicine where the lack of structural information in Single Photon Emission Computed Tomography (SPECT) images and Positron Emission Tomography (PET) images makes it difficult to assess the precise location of tissue with metabolic uptake, whereas Magnetic Resonance Imaging (MRI) and Computed Tomography (CT) can provide great anatomical details. The hardware approach to image fusion is to use hybrid scanners (SPECT/CT, PET/CT or PET/MRI). With this approach image fusion is simplified because the two scans are acquired sequentially (or simultaneously with PET/MR) which minimizes any motion. Hardware hybrid scanner designs are facing many challenges such as the conversion of CT numbers to attenuation coefficients, artefacts due to the presence of high Zeff material, and respiratory motion. Software approaches to multimodality imaging emerged in the late1980's and were using semi-automated or automatic approaches by registering surface contours or surface points. The big step towards fully automated software based image fusion appeared when the registration method started to use a direct analysis of image data to achieve an optimal registration often using iterative approaches to maximize mutual information between images. Software based image fusion is complex and involves many decisions regarding fusion tools, reconstruction techniques and final image presentation of fused data.",
keywords = "ET/CT, Hybrid scanner, Multi modality, PET/MRI, SPECT/CT",
author = "Klausen, {Thomas L.} and Flemming Andersen and Brad Kemp",
year = "2011",
month = "8",
language = "English (US)",
volume = "7",
pages = "169--174",
journal = "Current Medical Imaging Reviews",
issn = "1573-4056",
publisher = "Bentham Science Publishers B.V.",
number = "3",

}

TY - JOUR

T1 - Hardware and software approaches to multi-modality imaging

AU - Klausen, Thomas L.

AU - Andersen, Flemming

AU - Kemp, Brad

PY - 2011/8

Y1 - 2011/8

N2 - There has been a longstanding interest in multi-modality imaging especially in nuclear medicine where the lack of structural information in Single Photon Emission Computed Tomography (SPECT) images and Positron Emission Tomography (PET) images makes it difficult to assess the precise location of tissue with metabolic uptake, whereas Magnetic Resonance Imaging (MRI) and Computed Tomography (CT) can provide great anatomical details. The hardware approach to image fusion is to use hybrid scanners (SPECT/CT, PET/CT or PET/MRI). With this approach image fusion is simplified because the two scans are acquired sequentially (or simultaneously with PET/MR) which minimizes any motion. Hardware hybrid scanner designs are facing many challenges such as the conversion of CT numbers to attenuation coefficients, artefacts due to the presence of high Zeff material, and respiratory motion. Software approaches to multimodality imaging emerged in the late1980's and were using semi-automated or automatic approaches by registering surface contours or surface points. The big step towards fully automated software based image fusion appeared when the registration method started to use a direct analysis of image data to achieve an optimal registration often using iterative approaches to maximize mutual information between images. Software based image fusion is complex and involves many decisions regarding fusion tools, reconstruction techniques and final image presentation of fused data.

AB - There has been a longstanding interest in multi-modality imaging especially in nuclear medicine where the lack of structural information in Single Photon Emission Computed Tomography (SPECT) images and Positron Emission Tomography (PET) images makes it difficult to assess the precise location of tissue with metabolic uptake, whereas Magnetic Resonance Imaging (MRI) and Computed Tomography (CT) can provide great anatomical details. The hardware approach to image fusion is to use hybrid scanners (SPECT/CT, PET/CT or PET/MRI). With this approach image fusion is simplified because the two scans are acquired sequentially (or simultaneously with PET/MR) which minimizes any motion. Hardware hybrid scanner designs are facing many challenges such as the conversion of CT numbers to attenuation coefficients, artefacts due to the presence of high Zeff material, and respiratory motion. Software approaches to multimodality imaging emerged in the late1980's and were using semi-automated or automatic approaches by registering surface contours or surface points. The big step towards fully automated software based image fusion appeared when the registration method started to use a direct analysis of image data to achieve an optimal registration often using iterative approaches to maximize mutual information between images. Software based image fusion is complex and involves many decisions regarding fusion tools, reconstruction techniques and final image presentation of fused data.

KW - ET/CT

KW - Hybrid scanner

KW - Multi modality

KW - PET/MRI

KW - SPECT/CT

UR - http://www.scopus.com/inward/record.url?scp=79961068814&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79961068814&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:79961068814

VL - 7

SP - 169

EP - 174

JO - Current Medical Imaging Reviews

JF - Current Medical Imaging Reviews

SN - 1573-4056

IS - 3

ER -