External beam pulsed low dose radiotherapy using volumetric modulated arc therapy: Planning and delivery

Neelam Tyagi, Kai Yang, Raminder Sandhu, Di Yan, Sean S. Park, Peter Y. Chen, Brian Marples

Research output: Contribution to journalArticlepeer-review

6 Scopus citations

Abstract

Purpose: To evaluate the feasibility of planning and delivering pulsed low dose radiotherapy (PLRT) using volumetric modulated arc therapy (VMAT) on Elektalinacs. Methods: Ten patients previously treated for glioblastomamultiforme (GBM) were replanned using PLRT VMAT to deliver ten 0.2 Gy pulses separated by 3 min intervals with an effective dose rate of 0.067 Gy/min. VMAT parameters such as leaf speed and arc length were investigated to deliver 2 Gy/fraction to a total of 60 Gy to the target volume in ten subfractions or pulses. Plan quality was assessed using conformity and homogeneity indices. Absolute dose distribution for individual pulses was measured using ArcCHECK diode array. Individual pulses were analyzed for reproducibility and stability using machine log files. Machine characteristics at low monitor units and low dose rate were also investigated. Results: An optimal arc length of 140°-160° and a leaf speed of 0.18-0.25 cm/° were sufficient to provide equivalent plan coverage and stable delivery. The average time and dose rate required to deliver a single 0.2 Gy pulse was 39.5 ± 2.3 s and 49 ± 32.3 cGy/min. Average reductions in MUs for the VMAT PLRT plan compared to IMRT for PTV was 16% (Range: -5.5%-36.1%) and 10.9% (Range: -18.4%-32.3%) for the initial and boost plan. A significant improvement was seen in maximum doses to all sensitive structures when planned with VMAT PLRT. The average absolute dose gamma passing rate for the 10 pulses combined and 2 Gy plan were 91.6 ± 2.5% and 97.3 ± 1.2%, respectively. Cumulative monitor units, dose rate, gantry angles, and leaf positions evaluated using machine log files were within 2% for all pulses. Conclusions: Elekta linacs are capable of delivering reproducible and stable PLRT plans. A prospective clinical study employing PLRT is currently in development.

Original languageEnglish (US)
Article number011704
JournalMedical physics
Volume40
Issue number1
DOIs
StatePublished - Jan 2013

Keywords

  • arc length
  • glioblastomamultiforme (GBM)
  • leaf speed
  • pulsed low dose RT (PLRT)
  • volumetric modulated arc therapy (VMAT)

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'External beam pulsed low dose radiotherapy using volumetric modulated arc therapy: Planning and delivery'. Together they form a unique fingerprint.

Cite this