Effects of interleaf order for spiral MRI of dynamic processes

James Pipe, Ergun Ahunbay, Padmanabhan Menon

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

The effects of the temporal order in which spiral interleaves are collected are discussed, in the context of artifacts from moving or changing objects. Simulations and in vivo experiments demonstrate the properties of four different ordering methods. Specific applications discussed include cardiac and interventional magnetic resonance imaging, as well as inflow and contrast-enhanced magnetic resonance angiography.

Original languageEnglish (US)
Pages (from-to)417-422
Number of pages6
JournalMagnetic Resonance in Medicine
Volume41
Issue number2
DOIs
StatePublished - Jan 1 1999
Externally publishedYes

Fingerprint

Interventional Magnetic Resonance Imaging
Magnetic Resonance Angiography
Artifacts

Keywords

  • Cine
  • Interventional MRI
  • MR angiography
  • Spiral MRI

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Effects of interleaf order for spiral MRI of dynamic processes. / Pipe, James; Ahunbay, Ergun; Menon, Padmanabhan.

In: Magnetic Resonance in Medicine, Vol. 41, No. 2, 01.01.1999, p. 417-422.

Research output: Contribution to journalArticle

Pipe, James ; Ahunbay, Ergun ; Menon, Padmanabhan. / Effects of interleaf order for spiral MRI of dynamic processes. In: Magnetic Resonance in Medicine. 1999 ; Vol. 41, No. 2. pp. 417-422.
@article{01bb68d2d4104a4c8a10b79e2b96843a,
title = "Effects of interleaf order for spiral MRI of dynamic processes",
abstract = "The effects of the temporal order in which spiral interleaves are collected are discussed, in the context of artifacts from moving or changing objects. Simulations and in vivo experiments demonstrate the properties of four different ordering methods. Specific applications discussed include cardiac and interventional magnetic resonance imaging, as well as inflow and contrast-enhanced magnetic resonance angiography.",
keywords = "Cine, Interventional MRI, MR angiography, Spiral MRI",
author = "James Pipe and Ergun Ahunbay and Padmanabhan Menon",
year = "1999",
month = "1",
day = "1",
doi = "10.1002/(SICI)1522-2594(199902)41:2<417::AID-MRM29>3.0.CO;2-W",
language = "English (US)",
volume = "41",
pages = "417--422",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "2",

}

TY - JOUR

T1 - Effects of interleaf order for spiral MRI of dynamic processes

AU - Pipe, James

AU - Ahunbay, Ergun

AU - Menon, Padmanabhan

PY - 1999/1/1

Y1 - 1999/1/1

N2 - The effects of the temporal order in which spiral interleaves are collected are discussed, in the context of artifacts from moving or changing objects. Simulations and in vivo experiments demonstrate the properties of four different ordering methods. Specific applications discussed include cardiac and interventional magnetic resonance imaging, as well as inflow and contrast-enhanced magnetic resonance angiography.

AB - The effects of the temporal order in which spiral interleaves are collected are discussed, in the context of artifacts from moving or changing objects. Simulations and in vivo experiments demonstrate the properties of four different ordering methods. Specific applications discussed include cardiac and interventional magnetic resonance imaging, as well as inflow and contrast-enhanced magnetic resonance angiography.

KW - Cine

KW - Interventional MRI

KW - MR angiography

KW - Spiral MRI

UR - http://www.scopus.com/inward/record.url?scp=0033042005&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0033042005&partnerID=8YFLogxK

U2 - 10.1002/(SICI)1522-2594(199902)41:2<417::AID-MRM29>3.0.CO;2-W

DO - 10.1002/(SICI)1522-2594(199902)41:2<417::AID-MRM29>3.0.CO;2-W

M3 - Article

C2 - 10080293

AN - SCOPUS:0033042005

VL - 41

SP - 417

EP - 422

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 2

ER -