TY - JOUR
T1 - Edge-enhancing gradient echo with multi-image co-registration and averaging (EDGE-MICRA) for targeting thalamic centromedian and parafascicular nuclei
AU - Middlebrooks, Erik H.
AU - Okromelidze, Lela
AU - Lin, Chen
AU - Jain, Ayushi
AU - Westerhold, Erin
AU - Ritaccio, Anthony
AU - Quiñones-Hinojosa, Alfredo
AU - Gupta, Vivek
AU - Grewal, Sanjeet S.
N1 - Funding Information:
The author(s) disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: EHM receives unrelated research support from Boston Scientific Corp. and Varian Medical Systems, Inc., as well as unrelated consultant to Boston Scientific Corp. SSG is a consultant for Medtronic, Inc. and Boston Scientific Corp.
Publisher Copyright:
© The Author(s) 2021.
PY - 2021/12
Y1 - 2021/12
N2 - Background and purpose: Deep brain stimulation of the thalamus is an effective treatment for multiple neurological disorders. The centromedian and parafascicular nuclei are recently emerging targets for multiple conditions, such as epilepsy and Tourette syndrome; however, their limited visibility on conventional magnetic resonance imaging sequences has been a major obstacle. The goal of this study was to demonstrate the feasibility of a high-resolution and high-contrast targeting sequence for centromedian-parafascicular deep brain stimulation using a recently described magnetic resonance imaging sequence, three-dimensional edge-enhancing gradient echo. Methods: The three-dimensional edge-enhancing gradient echo sequence was performed on a normal volunteer for a total of six acquisitions. Multi-image co-registration and averaging was performed by first co-registering each of the six scans and then averaging to produce an edge-enhancing gradient echo-multi-image co-registration and averaging scan. The averaging was also performed for two, three, four and five scans to assess the change in the signal-to-noise ratio and identify the ideal balance of image quality and scan time. Results: The edge-enhancing gradient echo-multi-image co-registration and averaging scan allowed clear boundary delineation of the centromedian and parafascicular nuclei. The signal-to-noise ratio increased as a function of increasing scan number, but the added gain was small beyond four scans for the imaging parameters used in this study. Conclusions: The recently described three-dimensional edge-enhancing gradient echo sequence provides an easily implementable approach, using widely available magnetic resonance imaging technology without complex post-processing techniques, to delineate centromedian and parafascicular nuclei for deep brain stimulation targeting.
AB - Background and purpose: Deep brain stimulation of the thalamus is an effective treatment for multiple neurological disorders. The centromedian and parafascicular nuclei are recently emerging targets for multiple conditions, such as epilepsy and Tourette syndrome; however, their limited visibility on conventional magnetic resonance imaging sequences has been a major obstacle. The goal of this study was to demonstrate the feasibility of a high-resolution and high-contrast targeting sequence for centromedian-parafascicular deep brain stimulation using a recently described magnetic resonance imaging sequence, three-dimensional edge-enhancing gradient echo. Methods: The three-dimensional edge-enhancing gradient echo sequence was performed on a normal volunteer for a total of six acquisitions. Multi-image co-registration and averaging was performed by first co-registering each of the six scans and then averaging to produce an edge-enhancing gradient echo-multi-image co-registration and averaging scan. The averaging was also performed for two, three, four and five scans to assess the change in the signal-to-noise ratio and identify the ideal balance of image quality and scan time. Results: The edge-enhancing gradient echo-multi-image co-registration and averaging scan allowed clear boundary delineation of the centromedian and parafascicular nuclei. The signal-to-noise ratio increased as a function of increasing scan number, but the added gain was small beyond four scans for the imaging parameters used in this study. Conclusions: The recently described three-dimensional edge-enhancing gradient echo sequence provides an easily implementable approach, using widely available magnetic resonance imaging technology without complex post-processing techniques, to delineate centromedian and parafascicular nuclei for deep brain stimulation targeting.
KW - Epilepsy
KW - centromedian nucleus
KW - deep brain stimulation
KW - parafascicular nucleus
UR - http://www.scopus.com/inward/record.url?scp=85107834917&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85107834917&partnerID=8YFLogxK
U2 - 10.1177/19714009211021781
DO - 10.1177/19714009211021781
M3 - Article
C2 - 34121497
AN - SCOPUS:85107834917
SN - 1971-4009
VL - 34
SP - 667
EP - 675
JO - Neuroradiology Journal
JF - Neuroradiology Journal
IS - 6
ER -