TY - JOUR
T1 - Detection of prosthetic valve thrombosis using n'indium platelet imaging
AU - Acar, J.
AU - Vahanian, A.
AU - Dorent, R.
AU - Fauchet, M.
AU - Mundler, O.
AU - Michel, P. L.
AU - Roger, V.
AU - Cormier, B.
PY - 1990/5
Y1 - 1990/5
N2 - The diagnosis of prosthetic valve thrombosis (PVT) may be difficult in cases without valve obstruction. The aim of this study was to evaluate the diagnostic accuracy of111indiumlabelled autologous platelet imaging in the detection of PVT. We studied 41 patients with 45 prostheses, mechanical (37) or biological (8), in the mitral (26) or aortic (19) site. Mean age was 55 + 13 years. All these patients experienced one or several thromboembolic events (mean: 2.3 per patient). The mean interval between the last embolic event and indium test (IT) was 32 ± 25 days. Scintigrams were recorded in two views daily for 5 days. IT showed an abnormal platelet deposition on the prosthetic area in 24 patients. Platelet half-life was 3-8±10 days for patients with a positive IT and 4.6 ± 0.6 days for those with a negative IT (P < 0.01). Anatomical data were obtained in 10 cases (surgery nine, autopsy one) 16 ± 5 days after IT. All these patients had PVT, and IT was positive in eight cases. In the other 31 medically treated patients, recurrent embolism occurred within 12 months after IT in four cases, three of whom previously had a positive test. We conclude that IT is a useful means for detecting
AB - The diagnosis of prosthetic valve thrombosis (PVT) may be difficult in cases without valve obstruction. The aim of this study was to evaluate the diagnostic accuracy of111indiumlabelled autologous platelet imaging in the detection of PVT. We studied 41 patients with 45 prostheses, mechanical (37) or biological (8), in the mitral (26) or aortic (19) site. Mean age was 55 + 13 years. All these patients experienced one or several thromboembolic events (mean: 2.3 per patient). The mean interval between the last embolic event and indium test (IT) was 32 ± 25 days. Scintigrams were recorded in two views daily for 5 days. IT showed an abnormal platelet deposition on the prosthetic area in 24 patients. Platelet half-life was 3-8±10 days for patients with a positive IT and 4.6 ± 0.6 days for those with a negative IT (P < 0.01). Anatomical data were obtained in 10 cases (surgery nine, autopsy one) 16 ± 5 days after IT. All these patients had PVT, and IT was positive in eight cases. In the other 31 medically treated patients, recurrent embolism occurred within 12 months after IT in four cases, three of whom previously had a positive test. We conclude that IT is a useful means for detecting
KW - Indium platelet imaging
KW - Prosthetic valve
KW - Prosthetic valve thrombosis
UR - http://www.scopus.com/inward/record.url?scp=0025290433&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0025290433&partnerID=8YFLogxK
U2 - 10.1093/oxfordjournals.eurheartj.a059721
DO - 10.1093/oxfordjournals.eurheartj.a059721
M3 - Article
C2 - 2354700
AN - SCOPUS:0025290433
SN - 0195-668X
VL - 11
SP - 389
EP - 398
JO - European Heart Journal
JF - European Heart Journal
IS - 5
ER -