Bacterial Contamination of a Marking Pen in Anterior Cruciate Ligament Reconstruction

Taylor J. Ridley, Christopher T. Rud, Aaron Krych, Jeffrey A. Macalena

Research output: Contribution to journalArticle

Abstract

Background: A sterile surgical marking pen is commonly used during anterior cruciate ligament reconstruction (ACLR) to outline the proposed skin incision and then to mark the graft during preparation. Once in contact with the skin, the pen is a potential source of bacterial transmission and subsequent infections after ACLR. Purpose/Hypothesis: The purpose of this study was to assess whether the skin marking pen is a fomite for contamination during arthroscopic ACLR. We hypothesized that there would be a difference in the rate of culture-positive pens between control pens and the study pens used to delineate the proposed skin incision. Study Design: Controlled laboratory study. Methods: Twenty surgical marking pens were collected prospectively from patients undergoing ACLR over a 12-month period. All patients underwent standard preoperative sterile preparation and draping procedures. Proposed incisions were marked with a new sterile pen, and the pen tip was immediately sent for a 5-day inoculation in broth and agar. Negative controls (unopened new pen) and positive controls (used to mark the skin incisions preoperatively) were also cultured. Additionally, blank culture dishes were observed during the growth process. All pens were removed from the surgical field before incision, and new marking pens were used when needed during the procedure. Results: Three of the 20 study pens (15%) demonstrated positive growth. All 3 pens grew species of Staphylococcus. None of the negative controls demonstrated growth, 6 of the 12 positive controls showed growth, and none of the blank dishes exhibited growth. Conclusion: This study found a 15% rate of surgical marking pen contamination by Staphylococcus during ACLR. It is recommended that the skin marking pen not be used for any further steps of the surgical case and be discarded once used. Clinical Relevance: Infections after ACLR are rare but may result in significant morbidity, and all measures to reduce them should be pursued. Surgeons performing ACLR should dispose of the surgical marking pen after skin marking and before intraoperative use such as graft markup.

Original languageEnglish (US)
JournalOrthopaedic Journal of Sports Medicine
Volume6
Issue number5
DOIs
StatePublished - May 9 2018

Fingerprint

Anterior Cruciate Ligament Reconstruction
Skin
Growth
Staphylococcus
Fomites
Transplants
Infectious Disease Transmission
Agar
Morbidity
Infection

Keywords

  • ACL reconstruction
  • contamination
  • infection
  • marking pen
  • SSI

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine

Cite this

Bacterial Contamination of a Marking Pen in Anterior Cruciate Ligament Reconstruction. / Ridley, Taylor J.; Rud, Christopher T.; Krych, Aaron; Macalena, Jeffrey A.

In: Orthopaedic Journal of Sports Medicine, Vol. 6, No. 5, 09.05.2018.

Research output: Contribution to journalArticle

Ridley, Taylor J. ; Rud, Christopher T. ; Krych, Aaron ; Macalena, Jeffrey A. / Bacterial Contamination of a Marking Pen in Anterior Cruciate Ligament Reconstruction. In: Orthopaedic Journal of Sports Medicine. 2018 ; Vol. 6, No. 5.
@article{433f1dc7efe84ccabf7ca57482975339,
title = "Bacterial Contamination of a Marking Pen in Anterior Cruciate Ligament Reconstruction",
abstract = "Background: A sterile surgical marking pen is commonly used during anterior cruciate ligament reconstruction (ACLR) to outline the proposed skin incision and then to mark the graft during preparation. Once in contact with the skin, the pen is a potential source of bacterial transmission and subsequent infections after ACLR. Purpose/Hypothesis: The purpose of this study was to assess whether the skin marking pen is a fomite for contamination during arthroscopic ACLR. We hypothesized that there would be a difference in the rate of culture-positive pens between control pens and the study pens used to delineate the proposed skin incision. Study Design: Controlled laboratory study. Methods: Twenty surgical marking pens were collected prospectively from patients undergoing ACLR over a 12-month period. All patients underwent standard preoperative sterile preparation and draping procedures. Proposed incisions were marked with a new sterile pen, and the pen tip was immediately sent for a 5-day inoculation in broth and agar. Negative controls (unopened new pen) and positive controls (used to mark the skin incisions preoperatively) were also cultured. Additionally, blank culture dishes were observed during the growth process. All pens were removed from the surgical field before incision, and new marking pens were used when needed during the procedure. Results: Three of the 20 study pens (15{\%}) demonstrated positive growth. All 3 pens grew species of Staphylococcus. None of the negative controls demonstrated growth, 6 of the 12 positive controls showed growth, and none of the blank dishes exhibited growth. Conclusion: This study found a 15{\%} rate of surgical marking pen contamination by Staphylococcus during ACLR. It is recommended that the skin marking pen not be used for any further steps of the surgical case and be discarded once used. Clinical Relevance: Infections after ACLR are rare but may result in significant morbidity, and all measures to reduce them should be pursued. Surgeons performing ACLR should dispose of the surgical marking pen after skin marking and before intraoperative use such as graft markup.",
keywords = "ACL reconstruction, contamination, infection, marking pen, SSI",
author = "Ridley, {Taylor J.} and Rud, {Christopher T.} and Aaron Krych and Macalena, {Jeffrey A.}",
year = "2018",
month = "5",
day = "9",
doi = "10.1177/2325967118772043",
language = "English (US)",
volume = "6",
journal = "Orthopaedic Journal of Sports Medicine",
issn = "2325-9671",
publisher = "SAGE Publications Inc.",
number = "5",

}

TY - JOUR

T1 - Bacterial Contamination of a Marking Pen in Anterior Cruciate Ligament Reconstruction

AU - Ridley, Taylor J.

AU - Rud, Christopher T.

AU - Krych, Aaron

AU - Macalena, Jeffrey A.

PY - 2018/5/9

Y1 - 2018/5/9

N2 - Background: A sterile surgical marking pen is commonly used during anterior cruciate ligament reconstruction (ACLR) to outline the proposed skin incision and then to mark the graft during preparation. Once in contact with the skin, the pen is a potential source of bacterial transmission and subsequent infections after ACLR. Purpose/Hypothesis: The purpose of this study was to assess whether the skin marking pen is a fomite for contamination during arthroscopic ACLR. We hypothesized that there would be a difference in the rate of culture-positive pens between control pens and the study pens used to delineate the proposed skin incision. Study Design: Controlled laboratory study. Methods: Twenty surgical marking pens were collected prospectively from patients undergoing ACLR over a 12-month period. All patients underwent standard preoperative sterile preparation and draping procedures. Proposed incisions were marked with a new sterile pen, and the pen tip was immediately sent for a 5-day inoculation in broth and agar. Negative controls (unopened new pen) and positive controls (used to mark the skin incisions preoperatively) were also cultured. Additionally, blank culture dishes were observed during the growth process. All pens were removed from the surgical field before incision, and new marking pens were used when needed during the procedure. Results: Three of the 20 study pens (15%) demonstrated positive growth. All 3 pens grew species of Staphylococcus. None of the negative controls demonstrated growth, 6 of the 12 positive controls showed growth, and none of the blank dishes exhibited growth. Conclusion: This study found a 15% rate of surgical marking pen contamination by Staphylococcus during ACLR. It is recommended that the skin marking pen not be used for any further steps of the surgical case and be discarded once used. Clinical Relevance: Infections after ACLR are rare but may result in significant morbidity, and all measures to reduce them should be pursued. Surgeons performing ACLR should dispose of the surgical marking pen after skin marking and before intraoperative use such as graft markup.

AB - Background: A sterile surgical marking pen is commonly used during anterior cruciate ligament reconstruction (ACLR) to outline the proposed skin incision and then to mark the graft during preparation. Once in contact with the skin, the pen is a potential source of bacterial transmission and subsequent infections after ACLR. Purpose/Hypothesis: The purpose of this study was to assess whether the skin marking pen is a fomite for contamination during arthroscopic ACLR. We hypothesized that there would be a difference in the rate of culture-positive pens between control pens and the study pens used to delineate the proposed skin incision. Study Design: Controlled laboratory study. Methods: Twenty surgical marking pens were collected prospectively from patients undergoing ACLR over a 12-month period. All patients underwent standard preoperative sterile preparation and draping procedures. Proposed incisions were marked with a new sterile pen, and the pen tip was immediately sent for a 5-day inoculation in broth and agar. Negative controls (unopened new pen) and positive controls (used to mark the skin incisions preoperatively) were also cultured. Additionally, blank culture dishes were observed during the growth process. All pens were removed from the surgical field before incision, and new marking pens were used when needed during the procedure. Results: Three of the 20 study pens (15%) demonstrated positive growth. All 3 pens grew species of Staphylococcus. None of the negative controls demonstrated growth, 6 of the 12 positive controls showed growth, and none of the blank dishes exhibited growth. Conclusion: This study found a 15% rate of surgical marking pen contamination by Staphylococcus during ACLR. It is recommended that the skin marking pen not be used for any further steps of the surgical case and be discarded once used. Clinical Relevance: Infections after ACLR are rare but may result in significant morbidity, and all measures to reduce them should be pursued. Surgeons performing ACLR should dispose of the surgical marking pen after skin marking and before intraoperative use such as graft markup.

KW - ACL reconstruction

KW - contamination

KW - infection

KW - marking pen

KW - SSI

UR - http://www.scopus.com/inward/record.url?scp=85048261626&partnerID=8YFLogxK