Radiation Physicists

Research Output 1984 2020

Filter
Conference contribution
2019

Automatic strategy for CHO channel reduction in x-ray angiography systems

Gomez-Cardona, D., Leng, S., Favazza, C. P., Schueler, B. A. & Fetterly, K. A., Jan 1 2019, Medical Imaging 2019: Image Perception, Observer Performance, and Technology Assessment. Nishikawa, R. M. & Samuelson, F. W. (eds.). SPIE, 1095205. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; vol. 10952).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Angiography
angiography
X-Rays
Noise
X rays

Correlation between a deep-learning-based model observer and human observer for a realistic lung nodule localization task in chest CT

Gong, H., Walther, A., Hu, Q., Koo, C. W., Takahashi, E. A., Levin, D. L., Johnson, T. F., Hora, M. J., Leng, S., Fletcher, J. G., McCollough, C. H. & Yu, L., Jan 1 2019, Medical Imaging 2019: Image Perception, Observer Performance, and Technology Assessment. Nishikawa, R. M. & Samuelson, F. W. (eds.). SPIE, 109520K. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; vol. 10952).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

chest
nodules
lungs
learning
Thorax

Demonstration of phase-assisted material decomposition with a Talbot-Lau interferometer using a single x-ray tube potential

Shanblatt, E. R., Nelson, B. J., Tao, S., Leng, S. & McCollough, C. H., Jan 1 2019, Medical Imaging 2019: Physics of Medical Imaging. Bosmans, H., Chen, G-H. & Schmidt, T. G. (eds.). SPIE, 109482W. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; vol. 10948).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

x ray tubes
fats
Interferometers
Demonstrations
interferometers

Material decomposition in photon-counting-detector CT: Threshold or bin images?

Ren, L., Tao, S., McCollough, C. H. & Yu, L., Jan 1 2019, Medical Imaging 2019: Physics of Medical Imaging. Bosmans, H., Chen, G-H. & Schmidt, T. G. (eds.). SPIE, 109482S. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; vol. 10948).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Bins
Least-Squares Analysis
Photons
counting
Detectors

Multi-contrast imaging on dual-source photon-counting-detector (PCD) CT

Tao, S., Rajendran, K., McCollough, C. H. & Leng, S., Jan 1 2019, Medical Imaging 2019: Physics of Medical Imaging. Bosmans, H., Chen, G-H. & Schmidt, T. G. (eds.). SPIE, 109484L. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; vol. 10948).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Photons
Light sources
counting
Detectors
Imaging techniques

Multi-energy CT with triple x-ray beams and photon-counting-detector CT for simultaneous imaging of two contrast agents: An experimental comparison

Ren, L., McCollough, C. H. & Yu, L., Jan 1 2019, Medical Imaging 2019: Physics of Medical Imaging. Bosmans, H., Chen, G-H. & Schmidt, T. G. (eds.). SPIE, 109481B. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; vol. 10948).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Photons
Iodine
Contrast Media
counting
Bismuth

Multi-shell diffusion MRI measures of brain aging: A preliminary comparison from ADNI3

Nir, T. M., Thomopoulos, S. I., Villalon-Reina, J. E., Zavaliangos-Petropulu, A., Dennis, E. L., Reid, R. I., Bernstein, M. A., Borowski, B., Jack, C. R., Weiner, M. W., Jahanshad, N. & Thompson, P. M., Apr 2019, ISBI 2019 - 2019 IEEE International Symposium on Biomedical Imaging. IEEE Computer Society, p. 173-177 5 p. 8759486. (Proceedings - International Symposium on Biomedical Imaging; vol. 2019-April).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Diffusion Magnetic Resonance Imaging
Diffusion Tensor Imaging
Diffusion tensor imaging
Magnetic resonance imaging
Brain
1 Citation (Scopus)

Optimal acquisition setting for dual-contrast imaging with gadolinium and iodine on a research whole-body photon-counting-detector (PCD) CT

Tao, S., Wu, Y., Rajendran, K., McCollough, C. H. & Leng, S., Jan 1 2019, Medical Imaging 2019: Physics of Medical Imaging. Bosmans, H., Chen, G-H. & Schmidt, T. G. (eds.). SPIE, 109484I. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; vol. 10948).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Whole-Body Counting
Gadolinium
gadolinium
Iodine
Photons

Quantitative cartilage imaging using spectral photon-counting detector based computed tomography

Rajendran, K., Tao, S., Benike, A., Leng, S. & McCollough, C. H., Jan 1 2019, Medical Imaging 2019: Biomedical Applications in Molecular, Structural, and Functional Imaging. Gimi, B. & Krol, A. (eds.). SPIE, 109531A. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; vol. 10953).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

cartilage
Cartilage
Glycosaminoglycans
Photons
Tomography
1 Citation (Scopus)

Simulation of CT images reconstructed with different kernels using a convolutional neural network and its implications for efficient CT workflow

Missert, A. D., Leng, S., McCollough, C. H., Fletcher, J. G. & Yu, L., Jan 1 2019, Medical Imaging 2019: Physics of Medical Imaging. Bosmans, H., Chen, G-H. & Schmidt, T. G. (eds.). SPIE, 109482Y. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; vol. 10948).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Workflow
Tomography
tomography
X-Ray Computed Tomography Scanners
Neural networks

Visibility guided phase contrast denoising

Nelson, B., Koenig, T., Shanblatt, E., Leng, S. & McCollough, C. H., Jan 1 2019, Medical Imaging 2019: Physics of Medical Imaging. Bosmans, H., Chen, G-H. & Schmidt, T. G. (eds.). SPIE, 109484V. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; vol. 10948).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Interferometry
phase contrast
visibility
Visibility
low visibility
2018
1 Citation (Scopus)

Correlation between model observers in uniform background and human observers in patient liver background for a low-contrast detection task in CT

Gong, H., Yu, L., Leng, S., DIlger, S., Zhou, W., Ren, L. & McCollough, C. H., Jan 1 2018, Medical Imaging 2018: Image Perception, Observer Performance, and Technology Assessment. SPIE, Vol. 10577. 105770M

Research output: Chapter in Book/Report/Conference proceedingConference contribution

liver
Liver
lesions
Computerized tomography
Image quality
2 Citations (Scopus)

Determination of optimal image type and lowest detectable concentration for iodine detection on a photon counting detector-based multi-energy CT system

Zhou, W., Schornak, R., Michalak, G., Weaver, J., Abdurakhimova, D., Ferrero, A., Fetterly, K. A., McCollough, C. H. & Leng, S., Jan 1 2018, Medical Imaging 2018: Physics of Medical Imaging. SPIE, Vol. 10573. 105734U

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Iodine
Photons
iodine
low concentrations
counting
1 Citation (Scopus)

Impact of photon counting detector technology on kV selection and diagnostic workflow in CT

Zhou, W., Abdurakhimova, D., Bruesewitz, M., Halaweish, A., McCollough, C. H. & Leng, S., Jan 1 2018, Medical Imaging 2018: Physics of Medical Imaging. SPIE, Vol. 10573. 105731C

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Workflow
Iodine
Photons
Noise
counting
1 Citation (Scopus)

Ranking diffusion tensor measures of brain aging and Alzheimer's disease

Zavaliangos-Petropulu, A., Nir, T. M., Thomopoulos, S. I., Jahanshad, N., Reid, R. I., Bernstein, M. A., Borowski, B., Jack, C. R. J., Weiner, M. W. & Thompson, P. M., Jan 1 2018, 14th International Symposium on Medical Information Processing and Analysis. Lepore, N., Romero, E. & Brieva, J. (eds.). SPIE, Vol. 10975. 109750O

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Alzheimer's Disease
ranking
brain
Tensors
Brain
1 Citation (Scopus)

Simulating low-dose cone-beam CT: A phantom study

Ferrero, A., Fetterly, K., Yu, L. & Schueler, B. A., Jan 1 2018, Medical Imaging 2018: Physics of Medical Imaging. SPIE, Vol. 10573. 1057347

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Cone-Beam Computed Tomography
Cones
cones
dosage
Iodine
2 Citations (Scopus)

Three-material decomposition in multi-energy CT: Impact of prior information on noise and bias

Ren, L., McCollough, C. H. & Yu, L., Jan 1 2018, Medical Imaging 2018: Physics of Medical Imaging. SPIE, Vol. 10573. 105731G

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Noise
Decomposition
decomposition
Gadolinium
Photons
1 Citation (Scopus)

Ultra-high resolution photon-counting detector CT reconstruction using spectral prior image constrained compressed-sensing (UHR-SPICCS)

Rajendran, K., Tao, S., Abdurakhimova, D., Leng, S. & McCollough, C. H., Jan 1 2018, Medical Imaging 2018: Physics of Medical Imaging. SPIE, Vol. 10573. 1057318

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Compressed sensing
Photons
counting
Noise
Detectors
2017
3 Citations (Scopus)

A virtual clinical trial using projection-based nodule insertion to determine radiologist reader performance in lung cancer screening CT

Yu, L., Hu, Q., Koo, C. W., Takahashi, E. A., Levin, D. L., Johnson, T., Hora, M. J., Dirks, S., Chen, B., McMillan, K., Leng, S., Fletcher, J. G. & McCollough, C. H., 2017, Medical Imaging 2017: Physics of Medical Imaging. SPIE, Vol. 10132. 101321R

Research output: Chapter in Book/Report/Conference proceedingConference contribution

nodules
readers
Early Detection of Cancer
lungs
insertion
2 Citations (Scopus)

Detection of increased vasa vasorum in artery walls: Improving CT number accuracy using image deconvolution

Rajendran, K., Leng, S., Jorgensen, S. M., Abdurakhimova, D., Ritman, E. L. & McCollough, C. H., 2017, Medical Imaging 2017: Physics of Medical Imaging. SPIE, Vol. 10132. 101323O

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Vasa Vasorum
Deconvolution
arteries
Tomography
Arteries
2 Citations (Scopus)

Dual energy CT kidney stone differentiation in photon counting computed tomography

Gutjahr, R., Polster, C., Henning, A., Kappler, S., Leng, S., McCollough, C. H., Sedlmair, M. U., Schmidt, B., Krauss, B. & Flohr, T. G., 2017, Medical Imaging 2017: Physics of Medical Imaging. SPIE, Vol. 10132. 1013237

Research output: Chapter in Book/Report/Conference proceedingConference contribution

kidney stones
Apatites
Calcium Oxalate
Kidney Calculi
Apatite
3 Citations (Scopus)

Lung nodule volume quantification and shape differentiation with an ultra-high resolution technique on a photon counting detector CT system

Zhou, W., Montoya, J., Gutjahr, R., Ferrero, A., Halaweish, A., Kappler, S., McCollough, C. H. & Leng, S., 2017, Medical Imaging 2017: Physics of Medical Imaging. SPIE, Vol. 10132. 101323Q

Research output: Chapter in Book/Report/Conference proceedingConference contribution

nodules
Photons
ROC Curve
lungs
Macros
2 Citations (Scopus)

Practical implementation of channelized hotelling observers: Effect of ROI size

Ferrero, A., Favazza, C. P., Yu, L., Leng, S. & McCollough, C. H., 2017, Medical Imaging 2017: Physics of Medical Imaging. SPIE, Vol. 10132. 101320G

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Gabor filters
Diagnostic Imaging
Anatomy
Research Personnel
Image acquisition
2 Citations (Scopus)

Renal stone characterization using high resolution imaging mode on a photon counting detector CT system

Ferrero, A., Gutjahr, R., Henning, A., Kappler, S., Halaweish, A., Abdurakhimova, D., Peterson, Z., Montoya, J., Leng, S. & McCollough, C. H., 2017, Medical Imaging 2017: Physics of Medical Imaging. SPIE, Vol. 10132. 101323J

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Cystines
Calcium Oxalate
Cystine
Uric Acid
Photons
16 Citations (Scopus)

Ultra-high spatial resolution multi-energy CT using photon counting detector technology

Leng, S., Gutjahr, R., Ferrero, A., Kappler, S., Henning, A., Halaweish, A., Zhou, W., Montoya, J. & McCollough, C. H., 2017, Medical Imaging 2017: Physics of Medical Imaging. SPIE, Vol. 10132. 101320Y

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Photons
Macros
Noise
counting
spatial resolution
2016
13 Citations (Scopus)

A high-resolution imaging technique using a whole-body, research photon counting detector CT system

Leng, S., Yu, Z., Halaweish, A., Kappler, S., Hahn, K., Henning, A., Li, Z., Lane, J., Levin, D. L., Jorgensen, S., Ritman, E. & McCollough, C. H., 2016, Medical Imaging 2016: Physics of Medical Imaging. SPIE, Vol. 9783. 97831I

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Photons
imaging techniques
Temporal Bone
counting
Bone
4 Citations (Scopus)

An open library of CT patient projection data

Chen, B., Leng, S., Yu, L., Holmes III, D. R., Fletcher, J. G. & McCollough, C. H., 2016, Medical Imaging 2016: Physics of Medical Imaging. SPIE, Vol. 9783. 97831B

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Digital Imaging and Communications in Medicine (DICOM)
abdomen
chest
files
Abdomen
8 Citations (Scopus)

Arterial wall perfusion measured with photon counting spectral X-ray CT

Jorgensen, S. M., Korinek, M. J., Vercnocke, A. J., Anderson, J. L., Halaweish, A., Leng, S., McCollough, C. H. & Ritman, E. L., 2016, Developments in X-Ray Tomography X. SPIE, Vol. 9967. 99670B

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Photon Counting
Arteries
Contrast Media
counting
Photons
2 Citations (Scopus)

Diffusion tensor distribution function metrics boost power to detect deficits in Alzheimer's disease

Nir, T. M., Zavaliangos-Petropulu, A., Jahanshad, N., Villalon-Reina, J. E., Zhan, L., Leow, A. D., Bernstein, M. A., Jack, C. R. J., Weiner, M. W. & Thompson, P. M., Jun 15 2016, 2016 IEEE International Symposium on Biomedical Imaging: From Nano to Macro, ISBI 2016 - Proceedings. IEEE Computer Society, Vol. 2016-June. p. 1088-1092 5 p. 7493455

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Distribution functions
Tensors
Alzheimer Disease
Diffusion Magnetic Resonance Imaging
Magnetic resonance imaging
7 Citations (Scopus)

Dual-source multi-energy CT with triple or quadruple x-ray beams

Yu, L., Li, Z., Leng, S. & McCollough, C. H., 2016, Medical Imaging 2016: Physics of Medical Imaging. SPIE, Vol. 9783. 978312

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Photons
X-Rays
Decomposition
X rays
Contrast Media
1 Citation (Scopus)

Estimation of signal and noise for a whole-body photon counting research CT system

Li, Z., Leng, S., Yu, Z., Kappler, S. & McCollough, C. H., 2016, Medical Imaging 2016: Physics of Medical Imaging. SPIE, Vol. 9783. 97831F

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Whole-Body Counting
Photons
Noise
counting
photons
6 Citations (Scopus)

Evaluation of a photon counting Medipix3RX CZT spectral x-ray detector

Jorgensen, S. M., Vercnocke, A. J., Rundle, D. S., Butler, P. H., McCollough, C. H. & Ritman, E. L., 2016, Radiation Detectors: Systems and Applications XVII. SPIE, Vol. 9969. 99690J

Research output: Chapter in Book/Report/Conference proceedingConference contribution

X-ray Detectors
zinc tellurides
x ray detectors
cadmium tellurides
Photon Counting
3 Citations (Scopus)

Evaluation of a projection-domain lung nodule insertion technique in thoracic CT

Ma, C., Chen, B., Koo, C. W., Takahashi, E. A., Fletcher, J. G., McCollough, C. H., Levin, D. L., Kuzo, R. S., Viers, L. D., Vincent Sheldon, S. A., Leng, S. & Yu, L., 2016, Medical Imaging 2016: Physics of Medical Imaging. SPIE, Vol. 9783. 97835Y

Research output: Chapter in Book/Report/Conference proceedingConference contribution

nodules
lungs
lesions
Tomography
insertion
6 Citations (Scopus)

Low-dose performance of a whole-body research photon-counting CT scanner

Yu, Z., Leng, S., Kappler, S., Hahn, K., Li, Z., Halaweish, A. F., Henning, A., Ritman, E. L. & McCollough, C. H., 2016, Medical Imaging 2016: Physics of Medical Imaging. SPIE, Vol. 9783. 97835Q

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Photons
scanners
counting
dosage
photons
1 Citation (Scopus)

Performance measurements of a PET/CT system with prototype SiPM detectors

Kemp, B. J., Peterson, W. T., Uribe, J., Williams, J. J., Lowe, V. & Stearns, C. W., Oct 3 2016, 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2015. Institute of Electrical and Electronics Engineers Inc., 7582091

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Noise
prototypes
Detectors
Delivery of Health Care
gantry cranes

Phantom analysis for characterization and comparison of PET detector sampling and reconstruction settings

Wollenweber, S. D. & Kemp, B. J., Oct 3 2016, 2015 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS/MIC 2015. Institute of Electrical and Electronics Engineers Inc., 7582039

Research output: Chapter in Book/Report/Conference proceedingConference contribution

scanners
sampling
Sampling
Detectors
Imaging techniques
4 Citations (Scopus)

Predicting detection performance with model observers: Fourier domain or spatial domain?

Chen, B., Yu, L., Leng, S., Kofler, J., Favazza, C., Vrieze, T. & McCollough, C. H., 2016, Medical Imaging 2016: Physics of Medical Imaging. SPIE, Vol. 9783. 978326

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Computer-Assisted Image Processing
Image reconstruction
image reconstruction
Noise
inserts

Quantitative characterization of brain β-amyloid in 718 normal subjects using a joint PiB/FDG PET image histogram

Camp, J. J., Hanson, D. P., Lowe, V., Kemp, B. J., Senjem, M. L., Murray, M. E., Dickson, D. W., Parisi, J. E., Petersen, R. C., Robb, R. A. & Holmes III, D. R., 2016, Medical Imaging 2016: Computer-Aided Diagnosis. SPIE, Vol. 9785. 97852V

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Amyloid
histograms
brain
autopsies
Brain
2015
6 Citations (Scopus)

Construction of realistic liver phantoms from patient images using 3D printer and its application in CT image quality assessment

Leng, S., Yu, L., Vrieze, T., Kuhlmann, J., Chen, B. & McCollough, C. H., 2015, Progress in Biomedical Optics and Imaging - Proceedings of SPIE. SPIE, Vol. 9412. 94124E

Research output: Chapter in Book/Report/Conference proceedingConference contribution

3D printers
printers
liver
Liver
Image quality
3 Citations (Scopus)

DICOM index tracker enterprise: Advanced system for enterprise-wide quality assurance and patient safety monitoring

Zhang, M., Pavlicek, W., Panda, A., Langer, S. G., Morin, R., Fetterly, K. A., Paden, R., Hanson, J., Wu, L. W. & Wu, T., 2015, Progress in Biomedical Optics and Imaging - Proceedings of SPIE. SPIE, Vol. 9418. 94180L

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Digital Imaging and Communications in Medicine (DICOM)
Physiologic Monitoring
assurance
Patient Safety
Quality assurance
15 Citations (Scopus)

Feature selection improves the accuracy of classifying Alzheimer disease using diffusion tensor images

Demirhan, A., Nir, T. M., Zavaliangos-Petropulu, A., Jack, C. R. J., Weiner, M. W., Bernstein, M. A., Thompson, P. M. & Jahanshad, N., Jul 21 2015, Proceedings - International Symposium on Biomedical Imaging. IEEE Computer Society, Vol. 2015-July. p. 126-130 5 p. 7163832

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Tensors
Feature extraction
Alzheimer Disease
Diffusion Tensor Imaging
Diffusion tensor imaging
17 Citations (Scopus)

Image-based material decomposition with a general volume constraint for photon-counting CT

Li, Z., Leng, S., Yu, L., Yu, Z. & McCollough, C. H., 2015, Progress in Biomedical Optics and Imaging - Proceedings of SPIE. SPIE, Vol. 9412. 94120T

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Photons
counting
Decomposition
decomposition
photons

Impact of number of repeated scans on model observer performance for a low-contrast detection task in CT

Ma, C., Yu, L., Chen, B., Vrieze, T., Favazza, C., Leng, S. & McCollough, C. H., 2015, Progress in Biomedical Optics and Imaging - Proceedings of SPIE. SPIE, Vol. 9416. 94160K

Research output: Chapter in Book/Report/Conference proceedingConference contribution

ROC Curve
dosage
Covariance matrix
Image quality
filters
36 Citations (Scopus)

Initial results from a prototype whole-body photon-counting computed tomography system

Yu, Z., Leng, S., Jorgensen, S. M., Li, Z., Gutjahr, R., Chen, B., Duan, X., Halaweish, A. F., Yu, L., Ritman, E. L. & McCollough, C. H., 2015, Progress in Biomedical Optics and Imaging - Proceedings of SPIE. SPIE, Vol. 9412. 94120W

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Whole-Body Counting
Photons
Tomography
counting
tomography
5 Citations (Scopus)

Lesion insertion in projection domain for computed tomography image quality assessment

Chen, B., Ma, C., Yu, Z., Leng, S., Yu, L. & McCollough, C. H., 2015, Progress in Biomedical Optics and Imaging - Proceedings of SPIE. SPIE, Vol. 9412. 94121R

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Liver
lesions
Image quality
Tomography
insertion
11 Citations (Scopus)

Spectral graph theory and graph energy metrics show evidence for the Alzheimer's disease disconnection syndrome in APOE-4 risk gene carriers

Daianu, M., Mezher, A., Jahanshad, N., Hibar, D. P., Nir, T. M., Jack, C. R. J., Weiner, M. W., Bernstein, M. A. & Thompson, P. M., Jul 21 2015, Proceedings - International Symposium on Biomedical Imaging. IEEE Computer Society, Vol. 2015-July. p. 458-461 4 p. 7163910

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Graph theory
Alzheimer Disease
Genes
Brain
2014
10 Citations (Scopus)

Algebraic connectivity of brain networks shows patterns of segregation leading to reduced network robustness in Alzheimer’s disease

Daianu, M., Jahanshad, N., Nir, T. M., Leonardo, C. D., Jack, C. R. J., Weiner, M. W., Bernstein, M. A. & Thompson, P. M., 2014, Mathematics and Visualization. springer berlin, Vol. 39. p. 55-64 10 p. (Mathematics and Visualization; vol. 39).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Algebraic Connectivity
Alzheimer's Disease
Segregation
Network Connectivity
Brain

Determination of minor and trace elements in kidney stones by x-ray fluorescence analysis

Srivastava, A., Heisinger, B. J., Sinha, V., Lee, H. K., Liu, X., Qu, M., Duan, X., Leng, S. & McCollough, C. H., 2014, Progress in Biomedical Optics and Imaging - Proceedings of SPIE. SPIE, Vol. 9033. 90335R

Research output: Chapter in Book/Report/Conference proceedingConference contribution

kidney stones
x ray fluorescence
Kidney Calculi
Trace Elements
Trace elements
3 Citations (Scopus)

Development of an MRI fiducial marker prototype for automated MR-US fusion of abdominal images

Favazza, C. P., Gorny, K. R., Washburn, M. J. & Hangiandreou, N. J., 2014, Progress in Biomedical Optics and Imaging - Proceedings of SPIE. SPIE, Vol. 9033. 90334D

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Fiducial Markers
markers
Magnetic resonance imaging
fusion
prototypes
3 Citations (Scopus)

Evaluation of diffusion imaging protocols for the Alzheimer's disease neuroimaging initiative

Zhan, L., Bernstein, M. A., Borowski, B., Jack, C. R. J. & Thompson, P. M., Jul 29 2014, 2014 IEEE 11th International Symposium on Biomedical Imaging, ISBI 2014. Institute of Electrical and Electronics Engineers Inc., p. 710-713 4 p. 6867969

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Neuroimaging
Alzheimer Disease
Imaging techniques
Brain
Anisotropy