Real-time interactive magnetic resonance imaging

A. E. Holsinger, R. C. Wright, Stephen J Riederer, F. Farzaneh, R. C. Grimm, J. K. Maier

Research output: Contribution to journalArticle

49 Citations (Scopus)

Abstract

We describe a system for performing interactive MRI in real time. Using a TR/TE 7.1/3.5 ms sequence, the operator may alter a scan parameter and observe the effects of the alteration on the image within a few hundred milliseconds. With this system, we can interactively control the oblique scan slice orientation and, using inversion pulses, the image contrast.

Original languageEnglish (US)
Pages (from-to)547-553
Number of pages7
JournalMagnetic Resonance in Medicine
Volume14
Issue number3
DOIs
StatePublished - 1990

Fingerprint

Magnetic Resonance Imaging

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

Holsinger, A. E., Wright, R. C., Riederer, S. J., Farzaneh, F., Grimm, R. C., & Maier, J. K. (1990). Real-time interactive magnetic resonance imaging. Magnetic Resonance in Medicine, 14(3), 547-553. https://doi.org/10.1002/mrm.1910140312

Real-time interactive magnetic resonance imaging. / Holsinger, A. E.; Wright, R. C.; Riederer, Stephen J; Farzaneh, F.; Grimm, R. C.; Maier, J. K.

In: Magnetic Resonance in Medicine, Vol. 14, No. 3, 1990, p. 547-553.

Research output: Contribution to journalArticle

Holsinger, AE, Wright, RC, Riederer, SJ, Farzaneh, F, Grimm, RC & Maier, JK 1990, 'Real-time interactive magnetic resonance imaging', Magnetic Resonance in Medicine, vol. 14, no. 3, pp. 547-553. https://doi.org/10.1002/mrm.1910140312
Holsinger, A. E. ; Wright, R. C. ; Riederer, Stephen J ; Farzaneh, F. ; Grimm, R. C. ; Maier, J. K. / Real-time interactive magnetic resonance imaging. In: Magnetic Resonance in Medicine. 1990 ; Vol. 14, No. 3. pp. 547-553.
@article{f26631ad760c462a84b5dd2a89138b06,
title = "Real-time interactive magnetic resonance imaging",
abstract = "We describe a system for performing interactive MRI in real time. Using a TR/TE 7.1/3.5 ms sequence, the operator may alter a scan parameter and observe the effects of the alteration on the image within a few hundred milliseconds. With this system, we can interactively control the oblique scan slice orientation and, using inversion pulses, the image contrast.",
author = "Holsinger, {A. E.} and Wright, {R. C.} and Riederer, {Stephen J} and F. Farzaneh and Grimm, {R. C.} and Maier, {J. K.}",
year = "1990",
doi = "10.1002/mrm.1910140312",
language = "English (US)",
volume = "14",
pages = "547--553",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "3",

}

TY - JOUR

T1 - Real-time interactive magnetic resonance imaging

AU - Holsinger, A. E.

AU - Wright, R. C.

AU - Riederer, Stephen J

AU - Farzaneh, F.

AU - Grimm, R. C.

AU - Maier, J. K.

PY - 1990

Y1 - 1990

N2 - We describe a system for performing interactive MRI in real time. Using a TR/TE 7.1/3.5 ms sequence, the operator may alter a scan parameter and observe the effects of the alteration on the image within a few hundred milliseconds. With this system, we can interactively control the oblique scan slice orientation and, using inversion pulses, the image contrast.

AB - We describe a system for performing interactive MRI in real time. Using a TR/TE 7.1/3.5 ms sequence, the operator may alter a scan parameter and observe the effects of the alteration on the image within a few hundred milliseconds. With this system, we can interactively control the oblique scan slice orientation and, using inversion pulses, the image contrast.

UR - http://www.scopus.com/inward/record.url?scp=0025002941&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0025002941&partnerID=8YFLogxK

U2 - 10.1002/mrm.1910140312

DO - 10.1002/mrm.1910140312

M3 - Article

VL - 14

SP - 547

EP - 553

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 3

ER -