WE‐A‐M100J‐03 Dose Measurements and New Dose Reference Values

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Between Sept. 2002 and Dec. 2004, 829 scanners underwent the ACR CT accreditation process (178 in 2002, 396 in 2003, and 255 in 2004). Volume CTDI values (mean ± std. deviation) were 66.7±23.5, 57.8±16.6, 54.6±13.3, 58.4±17.7 (head), 17.2±9.7, 15.9±8.6, 14.0±7.0, 15.5±8.4 (pediatric abdomen), and 18.7±8.0, 19.2±8.6, 17.0±7.6, 18.4±8.3 (adult abdomen) for 2002, 2003, 2004, and 2002–2004, respectively. In every case except adult abdomen exams in 2003, both the mean dose and the std. dev. fell for each consecutive year. Similarly, the 75th and 90th %tile values and the percentage of units with doses over the reference levels consistently fell. In 2004, 22.4, 6.9, and 2.8% of sites reported doses above reference levels, compared to 49.0, 15.0, and 4.7% in 2002, for head, pediatric abdomen, and adult abdomen exams, respectively. In July 2007, the dose reference values for the program will be based on Volume CTDI to take into account the effect of pitch. The new diagnostic reference levels will be 75 mGy (head), 20 mGy (pediatric abdomen) and 25 mGy (adult abdomen). New to the program will be maximum allowable doses. Sites with doses above these values will not be eligible for accreditation. These values will be 80 mGy (head), 25 mGy (pediatric abdomen) and 30 mGy (adult abdomen). Educational Objectives: 1. Understand the dose data collected by the ACR CT Accreditation Program. 2. Be able to describe the data trends observed in the initial three years of the program. 3. Learn the new dose reference levels and maximum allowable doses that the program will adopt in July 2007.

Original languageEnglish (US)
Pages (from-to)2578-2579
Number of pages2
JournalMedical Physics
Volume34
Issue number6
DOIs
StatePublished - Jan 1 2007

Fingerprint

Abdomen
Reference Values
Accreditation
Head
Pediatrics

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Cite this

WE‐A‐M100J‐03 Dose Measurements and New Dose Reference Values. / McCollough, Cynthia H.

In: Medical Physics, Vol. 34, No. 6, 01.01.2007, p. 2578-2579.

Research output: Contribution to journalArticle

@article{5c8dfabd19234e639825744fe9da2884,
title = "WE‐A‐M100J‐03 Dose Measurements and New Dose Reference Values",
abstract = "Between Sept. 2002 and Dec. 2004, 829 scanners underwent the ACR CT accreditation process (178 in 2002, 396 in 2003, and 255 in 2004). Volume CTDI values (mean ± std. deviation) were 66.7±23.5, 57.8±16.6, 54.6±13.3, 58.4±17.7 (head), 17.2±9.7, 15.9±8.6, 14.0±7.0, 15.5±8.4 (pediatric abdomen), and 18.7±8.0, 19.2±8.6, 17.0±7.6, 18.4±8.3 (adult abdomen) for 2002, 2003, 2004, and 2002–2004, respectively. In every case except adult abdomen exams in 2003, both the mean dose and the std. dev. fell for each consecutive year. Similarly, the 75th and 90th {\%}tile values and the percentage of units with doses over the reference levels consistently fell. In 2004, 22.4, 6.9, and 2.8{\%} of sites reported doses above reference levels, compared to 49.0, 15.0, and 4.7{\%} in 2002, for head, pediatric abdomen, and adult abdomen exams, respectively. In July 2007, the dose reference values for the program will be based on Volume CTDI to take into account the effect of pitch. The new diagnostic reference levels will be 75 mGy (head), 20 mGy (pediatric abdomen) and 25 mGy (adult abdomen). New to the program will be maximum allowable doses. Sites with doses above these values will not be eligible for accreditation. These values will be 80 mGy (head), 25 mGy (pediatric abdomen) and 30 mGy (adult abdomen). Educational Objectives: 1. Understand the dose data collected by the ACR CT Accreditation Program. 2. Be able to describe the data trends observed in the initial three years of the program. 3. Learn the new dose reference levels and maximum allowable doses that the program will adopt in July 2007.",
author = "McCollough, {Cynthia H}",
year = "2007",
month = "1",
day = "1",
doi = "10.1118/1.2761466",
language = "English (US)",
volume = "34",
pages = "2578--2579",
journal = "Medical Physics",
issn = "0094-2405",
publisher = "AAPM - American Association of Physicists in Medicine",
number = "6",

}

TY - JOUR

T1 - WE‐A‐M100J‐03 Dose Measurements and New Dose Reference Values

AU - McCollough, Cynthia H

PY - 2007/1/1

Y1 - 2007/1/1

N2 - Between Sept. 2002 and Dec. 2004, 829 scanners underwent the ACR CT accreditation process (178 in 2002, 396 in 2003, and 255 in 2004). Volume CTDI values (mean ± std. deviation) were 66.7±23.5, 57.8±16.6, 54.6±13.3, 58.4±17.7 (head), 17.2±9.7, 15.9±8.6, 14.0±7.0, 15.5±8.4 (pediatric abdomen), and 18.7±8.0, 19.2±8.6, 17.0±7.6, 18.4±8.3 (adult abdomen) for 2002, 2003, 2004, and 2002–2004, respectively. In every case except adult abdomen exams in 2003, both the mean dose and the std. dev. fell for each consecutive year. Similarly, the 75th and 90th %tile values and the percentage of units with doses over the reference levels consistently fell. In 2004, 22.4, 6.9, and 2.8% of sites reported doses above reference levels, compared to 49.0, 15.0, and 4.7% in 2002, for head, pediatric abdomen, and adult abdomen exams, respectively. In July 2007, the dose reference values for the program will be based on Volume CTDI to take into account the effect of pitch. The new diagnostic reference levels will be 75 mGy (head), 20 mGy (pediatric abdomen) and 25 mGy (adult abdomen). New to the program will be maximum allowable doses. Sites with doses above these values will not be eligible for accreditation. These values will be 80 mGy (head), 25 mGy (pediatric abdomen) and 30 mGy (adult abdomen). Educational Objectives: 1. Understand the dose data collected by the ACR CT Accreditation Program. 2. Be able to describe the data trends observed in the initial three years of the program. 3. Learn the new dose reference levels and maximum allowable doses that the program will adopt in July 2007.

AB - Between Sept. 2002 and Dec. 2004, 829 scanners underwent the ACR CT accreditation process (178 in 2002, 396 in 2003, and 255 in 2004). Volume CTDI values (mean ± std. deviation) were 66.7±23.5, 57.8±16.6, 54.6±13.3, 58.4±17.7 (head), 17.2±9.7, 15.9±8.6, 14.0±7.0, 15.5±8.4 (pediatric abdomen), and 18.7±8.0, 19.2±8.6, 17.0±7.6, 18.4±8.3 (adult abdomen) for 2002, 2003, 2004, and 2002–2004, respectively. In every case except adult abdomen exams in 2003, both the mean dose and the std. dev. fell for each consecutive year. Similarly, the 75th and 90th %tile values and the percentage of units with doses over the reference levels consistently fell. In 2004, 22.4, 6.9, and 2.8% of sites reported doses above reference levels, compared to 49.0, 15.0, and 4.7% in 2002, for head, pediatric abdomen, and adult abdomen exams, respectively. In July 2007, the dose reference values for the program will be based on Volume CTDI to take into account the effect of pitch. The new diagnostic reference levels will be 75 mGy (head), 20 mGy (pediatric abdomen) and 25 mGy (adult abdomen). New to the program will be maximum allowable doses. Sites with doses above these values will not be eligible for accreditation. These values will be 80 mGy (head), 25 mGy (pediatric abdomen) and 30 mGy (adult abdomen). Educational Objectives: 1. Understand the dose data collected by the ACR CT Accreditation Program. 2. Be able to describe the data trends observed in the initial three years of the program. 3. Learn the new dose reference levels and maximum allowable doses that the program will adopt in July 2007.

UR - http://www.scopus.com/inward/record.url?scp=70349576751&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=70349576751&partnerID=8YFLogxK

U2 - 10.1118/1.2761466

DO - 10.1118/1.2761466

M3 - Article

AN - SCOPUS:70349576751

VL - 34

SP - 2578

EP - 2579

JO - Medical Physics

JF - Medical Physics

SN - 0094-2405

IS - 6

ER -