TY - JOUR
T1 - Validation of MRI-based measurements of supraspinatus morphology
AU - Nakajima, Tomotaka
AU - Hughes, Richard E.
AU - An, Kai Nan
PY - 2003/3/1
Y1 - 2003/3/1
N2 - The goal of this study was to visualize the supraspinatus tendon three-dimensionally using fast spin-echo (FSE) MRI and validate the accuracy of measuring the dimensions of the supraspinatus tendon based on 3D reconstructed images. Nine cadaver shoulders (51-84 y/o, mean 70.0 y/o) were imaged at conventional T2-weighted spin-echo (CSE), gradient echo (GRE), and 3D T2-weighted FSE sequences. Each "object" of the supraspinatus muscle, tendon and scapula was three-dimensionally reconstructed using ANALYZE™ image data processing software. The FSE images revealed significantly higher contrast of the tendon and contrast-to-noise ratios of the fat-to-tendon and fat-to-muscle. The length of the anterior, middle, and posterior portions of the tendon were measured in two ways: (1) from the three-dimensional reconstructed images, and (2) directly from the cadaver specimen using calipers. No statistically significant differences were found between the ANALYZE™ and caliper measurements using a paired t-test for the anterior (p = 0.55), middle (p = 0.57) and posterior (p = 0.44) portions of the supraspinatus. The 3D FSE sequence exhibits higher spatial resolution, spends shorter acquisition time, and constructs a voxel data set. These advantages can prevent blurring artifacts when imaging the supraspinatus tendon of a human body. Tendon length measurements derived from three-dimensional reconstructions using ANALYZE™ were found to be good estimates of actual tendon length. Therefore, the combination of FSE sequence and 3D image data processing provides a method for noninvasive quantitative analysis of supraspinatus tendon morphology. The results lay the groundwork for future quantitative studies of cuff pathology.
AB - The goal of this study was to visualize the supraspinatus tendon three-dimensionally using fast spin-echo (FSE) MRI and validate the accuracy of measuring the dimensions of the supraspinatus tendon based on 3D reconstructed images. Nine cadaver shoulders (51-84 y/o, mean 70.0 y/o) were imaged at conventional T2-weighted spin-echo (CSE), gradient echo (GRE), and 3D T2-weighted FSE sequences. Each "object" of the supraspinatus muscle, tendon and scapula was three-dimensionally reconstructed using ANALYZE™ image data processing software. The FSE images revealed significantly higher contrast of the tendon and contrast-to-noise ratios of the fat-to-tendon and fat-to-muscle. The length of the anterior, middle, and posterior portions of the tendon were measured in two ways: (1) from the three-dimensional reconstructed images, and (2) directly from the cadaver specimen using calipers. No statistically significant differences were found between the ANALYZE™ and caliper measurements using a paired t-test for the anterior (p = 0.55), middle (p = 0.57) and posterior (p = 0.44) portions of the supraspinatus. The 3D FSE sequence exhibits higher spatial resolution, spends shorter acquisition time, and constructs a voxel data set. These advantages can prevent blurring artifacts when imaging the supraspinatus tendon of a human body. Tendon length measurements derived from three-dimensional reconstructions using ANALYZE™ were found to be good estimates of actual tendon length. Therefore, the combination of FSE sequence and 3D image data processing provides a method for noninvasive quantitative analysis of supraspinatus tendon morphology. The results lay the groundwork for future quantitative studies of cuff pathology.
KW - Fast spin echo
KW - MRI
KW - Rotator cuff tear
KW - Supraspinatus tendon
UR - http://www.scopus.com/inward/record.url?scp=0038546408&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0038546408&partnerID=8YFLogxK
U2 - 10.1142/S021895770300096X
DO - 10.1142/S021895770300096X
M3 - Article
AN - SCOPUS:0038546408
SN - 0218-9577
VL - 7
SP - 15
EP - 23
JO - Journal of Musculoskeletal Research
JF - Journal of Musculoskeletal Research
IS - 1
ER -