Utilising multichannel intraluminal impedance for diagnosing GERD

A review

J. L. Wise, Joseph A Murray

Research output: Contribution to journalReview article

35 Citations (Scopus)

Abstract

The diagnosis of gastroesophageal reflux is sometimes challenging, especially when symptoms are unresponsive to high-dose acid suppression. With the advent of new technology it is possible to detect and quantify nonacid or weakly acidic reflux. Multichannel intraluminal impedance (MII), introduced over 10 years ago, is gaining popularity as a reflux detection tool. The ability to detect nonacid or weakly acidic reflux events, aerophagia, and to discern true reflux events from swallows could make it more a powerful tool than pH detection alone. This is a review of the role of MII as it pertains to the diagnosis of GERD and related disorders. Studies done on normal subjects and in GERD reveal that nonacid or weakly acidic reflux occurs frequently. Several studies have been published that document types and frequency or reflux episodes comparing pH to MII. pH electrodes fail to detect the majority of nonacid or weakly acidic reflux events. MII has revealed nonacid reflux to be less common in untreated GERD subjects than in normal subjects. GERD subjects have greater degrees of liquid-type reflux events compared to normal subjects who have more gas-type reflux events. In treated GERD subjects and normal subjects, proton pump inhibitors do not seem to decrease the amount of reflux but render the reflux nonacid or weakly acidic in nature. Recently work evaluating atypical symptoms of GERD with MII has been published.

Original languageEnglish (US)
Pages (from-to)83-88
Number of pages6
JournalDiseases of the Esophagus
Volume20
Issue number2
DOIs
StatePublished - Apr 2007

Fingerprint

Gastroesophageal Reflux
Electric Impedance
Swallows
Proton Pump Inhibitors
Electrodes
Gases
Technology
Acids

Keywords

  • Ambulatory monitoring
  • Esophagitis
  • Gastroesophagel reflux
  • Impedance
  • Nonacid reflux
  • PH monitoring

ASJC Scopus subject areas

  • Gastroenterology

Cite this

Utilising multichannel intraluminal impedance for diagnosing GERD : A review. / Wise, J. L.; Murray, Joseph A.

In: Diseases of the Esophagus, Vol. 20, No. 2, 04.2007, p. 83-88.

Research output: Contribution to journalReview article

@article{849b04d43f2b4daaa0bb35e5a6c57467,
title = "Utilising multichannel intraluminal impedance for diagnosing GERD: A review",
abstract = "The diagnosis of gastroesophageal reflux is sometimes challenging, especially when symptoms are unresponsive to high-dose acid suppression. With the advent of new technology it is possible to detect and quantify nonacid or weakly acidic reflux. Multichannel intraluminal impedance (MII), introduced over 10 years ago, is gaining popularity as a reflux detection tool. The ability to detect nonacid or weakly acidic reflux events, aerophagia, and to discern true reflux events from swallows could make it more a powerful tool than pH detection alone. This is a review of the role of MII as it pertains to the diagnosis of GERD and related disorders. Studies done on normal subjects and in GERD reveal that nonacid or weakly acidic reflux occurs frequently. Several studies have been published that document types and frequency or reflux episodes comparing pH to MII. pH electrodes fail to detect the majority of nonacid or weakly acidic reflux events. MII has revealed nonacid reflux to be less common in untreated GERD subjects than in normal subjects. GERD subjects have greater degrees of liquid-type reflux events compared to normal subjects who have more gas-type reflux events. In treated GERD subjects and normal subjects, proton pump inhibitors do not seem to decrease the amount of reflux but render the reflux nonacid or weakly acidic in nature. Recently work evaluating atypical symptoms of GERD with MII has been published.",
keywords = "Ambulatory monitoring, Esophagitis, Gastroesophagel reflux, Impedance, Nonacid reflux, PH monitoring",
author = "Wise, {J. L.} and Murray, {Joseph A}",
year = "2007",
month = "4",
doi = "10.1111/j.1442-2050.2007.00654.x",
language = "English (US)",
volume = "20",
pages = "83--88",
journal = "Diseases of the Esophagus",
issn = "1120-8694",
publisher = "Wiley-Blackwell",
number = "2",

}

TY - JOUR

T1 - Utilising multichannel intraluminal impedance for diagnosing GERD

T2 - A review

AU - Wise, J. L.

AU - Murray, Joseph A

PY - 2007/4

Y1 - 2007/4

N2 - The diagnosis of gastroesophageal reflux is sometimes challenging, especially when symptoms are unresponsive to high-dose acid suppression. With the advent of new technology it is possible to detect and quantify nonacid or weakly acidic reflux. Multichannel intraluminal impedance (MII), introduced over 10 years ago, is gaining popularity as a reflux detection tool. The ability to detect nonacid or weakly acidic reflux events, aerophagia, and to discern true reflux events from swallows could make it more a powerful tool than pH detection alone. This is a review of the role of MII as it pertains to the diagnosis of GERD and related disorders. Studies done on normal subjects and in GERD reveal that nonacid or weakly acidic reflux occurs frequently. Several studies have been published that document types and frequency or reflux episodes comparing pH to MII. pH electrodes fail to detect the majority of nonacid or weakly acidic reflux events. MII has revealed nonacid reflux to be less common in untreated GERD subjects than in normal subjects. GERD subjects have greater degrees of liquid-type reflux events compared to normal subjects who have more gas-type reflux events. In treated GERD subjects and normal subjects, proton pump inhibitors do not seem to decrease the amount of reflux but render the reflux nonacid or weakly acidic in nature. Recently work evaluating atypical symptoms of GERD with MII has been published.

AB - The diagnosis of gastroesophageal reflux is sometimes challenging, especially when symptoms are unresponsive to high-dose acid suppression. With the advent of new technology it is possible to detect and quantify nonacid or weakly acidic reflux. Multichannel intraluminal impedance (MII), introduced over 10 years ago, is gaining popularity as a reflux detection tool. The ability to detect nonacid or weakly acidic reflux events, aerophagia, and to discern true reflux events from swallows could make it more a powerful tool than pH detection alone. This is a review of the role of MII as it pertains to the diagnosis of GERD and related disorders. Studies done on normal subjects and in GERD reveal that nonacid or weakly acidic reflux occurs frequently. Several studies have been published that document types and frequency or reflux episodes comparing pH to MII. pH electrodes fail to detect the majority of nonacid or weakly acidic reflux events. MII has revealed nonacid reflux to be less common in untreated GERD subjects than in normal subjects. GERD subjects have greater degrees of liquid-type reflux events compared to normal subjects who have more gas-type reflux events. In treated GERD subjects and normal subjects, proton pump inhibitors do not seem to decrease the amount of reflux but render the reflux nonacid or weakly acidic in nature. Recently work evaluating atypical symptoms of GERD with MII has been published.

KW - Ambulatory monitoring

KW - Esophagitis

KW - Gastroesophagel reflux

KW - Impedance

KW - Nonacid reflux

KW - PH monitoring

UR - http://www.scopus.com/inward/record.url?scp=34147113785&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34147113785&partnerID=8YFLogxK

U2 - 10.1111/j.1442-2050.2007.00654.x

DO - 10.1111/j.1442-2050.2007.00654.x

M3 - Review article

VL - 20

SP - 83

EP - 88

JO - Diseases of the Esophagus

JF - Diseases of the Esophagus

SN - 1120-8694

IS - 2

ER -