Use of k Z -space for high through-plane resolution in multislice MRI: Application to prostate

Soudabeh Kargar, Eric A. Borisch, Adam T. Froemming, Roger C. Grimm, Akira Kawashima, Bernard Francis King, Eric G. Stinson, Stephen J Riederer

Research output: Contribution to journalArticle

Abstract

Purpose: The goal of this work is to demonstrate 1 mm through-plane resolution in multislice T2SE MRI using k Z -space processing of overlapping slices and show applicability in prostate MRI. Methods: Multiple overlapped slices are acquired and Fourier transformed in the slice-select direction. The slice profile is incorporated into a Tikhonov-regularized reconstruction. Through-plane resolution is tested in a resolution phantom. An anthropomorphic prostate phantom is used to study the SNR, and results are compared with theoretical prediction. The proposed method is tested in 16 patients indicated for clinical prostate MRI who gave written informed consent as overseen by our IRB. The “proposed” vs. “reference” multislice images are compared using multiple evaluation criteria for through-plane resolution. Results: The modulation transfer function (MTF) plots of the resolution phantom show good modulation at frequency 0.5 lp/mm, demonstrating 1 mm through-plane resolution restoration. The SNR measurements experimentally match the theoretically predicted values. The radiological evaluation shows that the proposed method is superior to the reference method for five criteria of sharpness but inferior with respect to artifacts. Conclusions: In conjunction with overlapped slices a k Z -space-based reconstruction approach can be used to improve through-plane resolution in multislice T2SE MRI. 1 mm resolution is demonstrated from 3.2 mm thick slices. The in vivo results from prostate MRI show improved sharpness when compared to the standard multislice method.

Original languageEnglish (US)
Pages (from-to)3691-3704
Number of pages14
JournalMagnetic Resonance in Medicine
Volume81
Issue number6
DOIs
StatePublished - Jun 1 2019

Fingerprint

Prostate
Research Ethics Committees
Informed Consent
Artifacts

Keywords

  • MRI
  • multislice
  • reconstruction
  • T2-weighted Spin Echo
  • through plane resolution

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Use of k Z -space for high through-plane resolution in multislice MRI : Application to prostate. / Kargar, Soudabeh; Borisch, Eric A.; Froemming, Adam T.; Grimm, Roger C.; Kawashima, Akira; King, Bernard Francis; Stinson, Eric G.; Riederer, Stephen J.

In: Magnetic Resonance in Medicine, Vol. 81, No. 6, 01.06.2019, p. 3691-3704.

Research output: Contribution to journalArticle

Kargar, Soudabeh ; Borisch, Eric A. ; Froemming, Adam T. ; Grimm, Roger C. ; Kawashima, Akira ; King, Bernard Francis ; Stinson, Eric G. ; Riederer, Stephen J. / Use of k Z -space for high through-plane resolution in multislice MRI : Application to prostate. In: Magnetic Resonance in Medicine. 2019 ; Vol. 81, No. 6. pp. 3691-3704.
@article{cf6567feeba84d1fa3a7d764fb3d292e,
title = "Use of k Z -space for high through-plane resolution in multislice MRI: Application to prostate",
abstract = "Purpose: The goal of this work is to demonstrate 1 mm through-plane resolution in multislice T2SE MRI using k Z -space processing of overlapping slices and show applicability in prostate MRI. Methods: Multiple overlapped slices are acquired and Fourier transformed in the slice-select direction. The slice profile is incorporated into a Tikhonov-regularized reconstruction. Through-plane resolution is tested in a resolution phantom. An anthropomorphic prostate phantom is used to study the SNR, and results are compared with theoretical prediction. The proposed method is tested in 16 patients indicated for clinical prostate MRI who gave written informed consent as overseen by our IRB. The “proposed” vs. “reference” multislice images are compared using multiple evaluation criteria for through-plane resolution. Results: The modulation transfer function (MTF) plots of the resolution phantom show good modulation at frequency 0.5 lp/mm, demonstrating 1 mm through-plane resolution restoration. The SNR measurements experimentally match the theoretically predicted values. The radiological evaluation shows that the proposed method is superior to the reference method for five criteria of sharpness but inferior with respect to artifacts. Conclusions: In conjunction with overlapped slices a k Z -space-based reconstruction approach can be used to improve through-plane resolution in multislice T2SE MRI. 1 mm resolution is demonstrated from 3.2 mm thick slices. The in vivo results from prostate MRI show improved sharpness when compared to the standard multislice method.",
keywords = "MRI, multislice, reconstruction, T2-weighted Spin Echo, through plane resolution",
author = "Soudabeh Kargar and Borisch, {Eric A.} and Froemming, {Adam T.} and Grimm, {Roger C.} and Akira Kawashima and King, {Bernard Francis} and Stinson, {Eric G.} and Riederer, {Stephen J}",
year = "2019",
month = "6",
day = "1",
doi = "10.1002/mrm.27691",
language = "English (US)",
volume = "81",
pages = "3691--3704",
journal = "Magnetic Resonance in Medicine",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "6",

}

TY - JOUR

T1 - Use of k Z -space for high through-plane resolution in multislice MRI

T2 - Application to prostate

AU - Kargar, Soudabeh

AU - Borisch, Eric A.

AU - Froemming, Adam T.

AU - Grimm, Roger C.

AU - Kawashima, Akira

AU - King, Bernard Francis

AU - Stinson, Eric G.

AU - Riederer, Stephen J

PY - 2019/6/1

Y1 - 2019/6/1

N2 - Purpose: The goal of this work is to demonstrate 1 mm through-plane resolution in multislice T2SE MRI using k Z -space processing of overlapping slices and show applicability in prostate MRI. Methods: Multiple overlapped slices are acquired and Fourier transformed in the slice-select direction. The slice profile is incorporated into a Tikhonov-regularized reconstruction. Through-plane resolution is tested in a resolution phantom. An anthropomorphic prostate phantom is used to study the SNR, and results are compared with theoretical prediction. The proposed method is tested in 16 patients indicated for clinical prostate MRI who gave written informed consent as overseen by our IRB. The “proposed” vs. “reference” multislice images are compared using multiple evaluation criteria for through-plane resolution. Results: The modulation transfer function (MTF) plots of the resolution phantom show good modulation at frequency 0.5 lp/mm, demonstrating 1 mm through-plane resolution restoration. The SNR measurements experimentally match the theoretically predicted values. The radiological evaluation shows that the proposed method is superior to the reference method for five criteria of sharpness but inferior with respect to artifacts. Conclusions: In conjunction with overlapped slices a k Z -space-based reconstruction approach can be used to improve through-plane resolution in multislice T2SE MRI. 1 mm resolution is demonstrated from 3.2 mm thick slices. The in vivo results from prostate MRI show improved sharpness when compared to the standard multislice method.

AB - Purpose: The goal of this work is to demonstrate 1 mm through-plane resolution in multislice T2SE MRI using k Z -space processing of overlapping slices and show applicability in prostate MRI. Methods: Multiple overlapped slices are acquired and Fourier transformed in the slice-select direction. The slice profile is incorporated into a Tikhonov-regularized reconstruction. Through-plane resolution is tested in a resolution phantom. An anthropomorphic prostate phantom is used to study the SNR, and results are compared with theoretical prediction. The proposed method is tested in 16 patients indicated for clinical prostate MRI who gave written informed consent as overseen by our IRB. The “proposed” vs. “reference” multislice images are compared using multiple evaluation criteria for through-plane resolution. Results: The modulation transfer function (MTF) plots of the resolution phantom show good modulation at frequency 0.5 lp/mm, demonstrating 1 mm through-plane resolution restoration. The SNR measurements experimentally match the theoretically predicted values. The radiological evaluation shows that the proposed method is superior to the reference method for five criteria of sharpness but inferior with respect to artifacts. Conclusions: In conjunction with overlapped slices a k Z -space-based reconstruction approach can be used to improve through-plane resolution in multislice T2SE MRI. 1 mm resolution is demonstrated from 3.2 mm thick slices. The in vivo results from prostate MRI show improved sharpness when compared to the standard multislice method.

KW - MRI

KW - multislice

KW - reconstruction

KW - T2-weighted Spin Echo

KW - through plane resolution

UR - http://www.scopus.com/inward/record.url?scp=85062800466&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85062800466&partnerID=8YFLogxK

U2 - 10.1002/mrm.27691

DO - 10.1002/mrm.27691

M3 - Article

C2 - 30844092

AN - SCOPUS:85062800466

VL - 81

SP - 3691

EP - 3704

JO - Magnetic Resonance in Medicine

JF - Magnetic Resonance in Medicine

SN - 0740-3194

IS - 6

ER -