Transluminale ausschaltung eines arteria subclavia-aneurysmas mittels stent-graft-implantation

Translated title of the contribution: Transluminal exclusion of a subclavian artery aneurysm with a covered stent graft

H. Eggebrecht, C. Bruch, M. Haude, O. Oldenburg, J. Herrmann, C. Von Birgelen, P. Hunold, D. Baumgart, R. Erbel

Research output: Contribution to journalArticle

5 Scopus citations

Abstract

In a 73 year-old male patient with generalized atherosclerosis, known infrarenal abdominal aortic aneurysm, renal artery stenosis, and coronary artery disease, an aneurysm of the proximal left subclavian artery was successfully excluded by implantation of a JOSTENT(TM)-Peripheral stent graft. Angiographic follow up after 6 and 12 months showed an excellent outcome with complete exclusion of the aneurysm. Intravascular ultrasound showed no neo-intimal hyperplasia within the stent. A computed tomography revealed complete thrombosis of the aneurysm.

Original languageGerman
Pages (from-to)761-765
Number of pages5
JournalZeitschrift fur Kardiologie
Volume89
Issue number9
DOIs
StatePublished - Jan 1 2000

    Fingerprint

Keywords

  • Stent graft
  • Subclavian aneurysm
  • Transluminal exclusion

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

Eggebrecht, H., Bruch, C., Haude, M., Oldenburg, O., Herrmann, J., Von Birgelen, C., Hunold, P., Baumgart, D., & Erbel, R. (2000). Transluminale ausschaltung eines arteria subclavia-aneurysmas mittels stent-graft-implantation. Zeitschrift fur Kardiologie, 89(9), 761-765. https://doi.org/10.1007/s003920070179