TY - JOUR
T1 - Toroidal geometry
T2 - novel three-dimensional intracardiac imaging with a phased-array transducer
AU - Belohlavek, Marek
AU - MacLellan-Tobert, Susan G.
AU - Seward, James B.
AU - Greenleaf, James F.
N1 - Funding Information:
We thank David T. Smyrk and Julie M. Patterson for assistance with illustrations and Elaine C. Quarve for preparation of the manuscript. This project was supported in part by the National Institutes of Health grants HL 52494 and HL 41046.
PY - 1997
Y1 - 1997
N2 - Recent advances in small, linear-array transducers have opened new avenues for three-dimensional image acquisition from an intracardiac approach. The purpose of this study was to introduce a novel method of image acquisition using toroidal geometry, explore its fidelity of reproduction of three-dimensional cardiac anatomy, and determine whether a whole-heart scan is achievable. Acquisition was accomplished through 360-degree incremental rotation of a rigid endoscope with a side-mounted ultrasound transducer. The procedure was first tested with the use of a gelatin model to define far-field slice resolution with 1.8-degree rotational increments. Comparison of three-dimensional scans of cardiac specimens with corresponding photographs confirmed that toroidal geometry can provide a high-quality display of structures from all sides. We conclude that whole-heart three-dimensional scanning from within the cardiac chambers is possible with toroidal geometry. The quality of depicted anatomy depends on transducer location within the heart, distance from the transducer, density of slices, and image resolution. The potential of intracardiac three-dimensional ultrasound imaging includes detailed spatial evaluation of cardiac morphology, determination of appropriate placement of investigative or therapeutic devices (catheters, closure devices, etc.), and assessment of cardiac function.
AB - Recent advances in small, linear-array transducers have opened new avenues for three-dimensional image acquisition from an intracardiac approach. The purpose of this study was to introduce a novel method of image acquisition using toroidal geometry, explore its fidelity of reproduction of three-dimensional cardiac anatomy, and determine whether a whole-heart scan is achievable. Acquisition was accomplished through 360-degree incremental rotation of a rigid endoscope with a side-mounted ultrasound transducer. The procedure was first tested with the use of a gelatin model to define far-field slice resolution with 1.8-degree rotational increments. Comparison of three-dimensional scans of cardiac specimens with corresponding photographs confirmed that toroidal geometry can provide a high-quality display of structures from all sides. We conclude that whole-heart three-dimensional scanning from within the cardiac chambers is possible with toroidal geometry. The quality of depicted anatomy depends on transducer location within the heart, distance from the transducer, density of slices, and image resolution. The potential of intracardiac three-dimensional ultrasound imaging includes detailed spatial evaluation of cardiac morphology, determination of appropriate placement of investigative or therapeutic devices (catheters, closure devices, etc.), and assessment of cardiac function.
UR - http://www.scopus.com/inward/record.url?scp=0031154599&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0031154599&partnerID=8YFLogxK
U2 - 10.1016/S0894-7317(97)70001-4
DO - 10.1016/S0894-7317(97)70001-4
M3 - Article
C2 - 9203487
AN - SCOPUS:0031154599
SN - 0894-7317
VL - 10
SP - 493
EP - 498
JO - Journal of the American Society of Echocardiography
JF - Journal of the American Society of Echocardiography
IS - 5
ER -