T1 - Three-dimensional surface strain analyses of simulated defect and augmented spine segments
T2 - A biomechanical cadaveric study
AU - Rezaei, Asghar
AU - Tilton, Maryam
AU - Giambini, Hugo
AU - Li, Yong
AU - Hooke, Alexander
AU - Miller, Alan L.
AU - Yaszemski, Michael J.
AU - Lu, Lichun
N1 - Funding Information:
This work was supported by National Institutes of Health grant R01 AR 56212 and the Eagles 5th District Cancer Telethon Funds for Cancer Research. MT was supported by National Institute of Health grant (T32AR56950) for Musculoskeletal Research Training.
Publisher Copyright:
© 2021
PY - 2021/7
Y1 - 2021/7
N2 - While several studies have investigated fracture outcomes of intact vertebrae, fracture properties in metastatically-involved and augmented vertebrae are still far from understood. Consequently, this study was aimed to use 3D digital image correlation (3D-DIC) method to investigate the failure properties of spine segments with simulated metastatic lesions, segments augmented with poly(propylene fumarate) (PPF), and compare the outcomes with intact spines. To this end, biomechanical experiments accompanied by 3D-DIC were performed on spine segments consisting of three vertebrae and two intervertebral discs (IVDs) at loading rates of 0.083 mm/s, mimicking a physiological loading condition, and 200 mm/s, mimicking an impact-type loading condition such as a fall or an accident. Full-field surface strain analysis indicated PPF augmentation reduces the superior/inferior strain when compared with the defect specimens; Presence of a defect in the middle vertebra resulted in shear band fracture pattern. Failure of the superior endplates was confirmed in several defect specimens as the superior IVDs were protruding out of defects. The augmenting PPF showed lower superior/inferior surface strain values at the fast speed as compared to the slow speed. The results of our study showed a significant increase in the fracture force from slow to fast speeds (p = 0.0246). The significance of the study was to determine the fracture properties of normal, pathological, and augmented spinal segments under physiologically-relevant loading conditions. Understanding failure properties associated with either defect (i.e., metastasis lesion) or augmented (i.e., post-treatment) spine segments could potentially provide new insights on the outcome prediction and treatment planning. Additionally, this study provides new knowledge on the effect of PPF augmentation in improving fracture properties, potentially decreasing the risk of fracture in osteoporotic and metastatic spines.
AB - While several studies have investigated fracture outcomes of intact vertebrae, fracture properties in metastatically-involved and augmented vertebrae are still far from understood. Consequently, this study was aimed to use 3D digital image correlation (3D-DIC) method to investigate the failure properties of spine segments with simulated metastatic lesions, segments augmented with poly(propylene fumarate) (PPF), and compare the outcomes with intact spines. To this end, biomechanical experiments accompanied by 3D-DIC were performed on spine segments consisting of three vertebrae and two intervertebral discs (IVDs) at loading rates of 0.083 mm/s, mimicking a physiological loading condition, and 200 mm/s, mimicking an impact-type loading condition such as a fall or an accident. Full-field surface strain analysis indicated PPF augmentation reduces the superior/inferior strain when compared with the defect specimens; Presence of a defect in the middle vertebra resulted in shear band fracture pattern. Failure of the superior endplates was confirmed in several defect specimens as the superior IVDs were protruding out of defects. The augmenting PPF showed lower superior/inferior surface strain values at the fast speed as compared to the slow speed. The results of our study showed a significant increase in the fracture force from slow to fast speeds (p = 0.0246). The significance of the study was to determine the fracture properties of normal, pathological, and augmented spinal segments under physiologically-relevant loading conditions. Understanding failure properties associated with either defect (i.e., metastasis lesion) or augmented (i.e., post-treatment) spine segments could potentially provide new insights on the outcome prediction and treatment planning. Additionally, this study provides new knowledge on the effect of PPF augmentation in improving fracture properties, potentially decreasing the risk of fracture in osteoporotic and metastatic spines.
KW - Biomechanics of vertebral bodies
KW - Fracture outcomes
KW - Mechanical testing
KW - Metastasis
KW - Vertebral augmentation
UR - http://www.scopus.com/inward/record.url?scp=85105691590&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85105691590&partnerID=8YFLogxK
U2 - 10.1016/j.jmbbm.2021.104559
DO - 10.1016/j.jmbbm.2021.104559
M3 - Article
C2 - 33915439
AN - SCOPUS:85105691590
SN - 1751-6161
VL - 119
JO - Journal of the Mechanical Behavior of Biomedical Materials
JF - Journal of the Mechanical Behavior of Biomedical Materials
M1 - 104559
ER -