TY - JOUR
T1 - Three-dimensional spatial, density, and temporal resolution of the dynamic spatial reconstructor
AU - Behrenbeck, T.
AU - Kinsey, J. H.
AU - Harris, L. D.
AU - Robb, R. A.
AU - Ritman, E. L.
PY - 1982/12
Y1 - 1982/12
N2 - Spatial, density, and temporal resolution of the dynamic spatial reconstructor (DSR), a multiple X-ray source, high speed, computed tomography scanning system, are evaluated. Hole-pair resolution was evaluated in a stationary phantom surrounded with air, 15 cm of water, or 20 cm of water. Temporal resolution was evaluated by rotation of one of the resolution phantoms during the scan, and with a balloon inflated to a known volume and at a known rate to approximate a typical left ventricular chamber volume and filling rate. These studies confirmed that the spatial resolution is essentially the same in the transverse and axial directions, and that retrospective manipulation of the image data is important for maximization of spatial and density resolution in any structure under examination by obtaining a tradeoff with partial-volume and motion-blurring effects. Maximum spatial resolution in the scanned volume was shown, under ideal conditions, to be greater than five hole pairs per centimeter. Under conditions of intravenous injection of contrast agent, the resolution of blood vessels in an experimental animal approximately 25 kg in weight is expected to be on the order of three hole pairs per centimeter; and in an adult human weighing approximately 60 kg, a resolution of about two hole pairs per centimeter is to be expected.
AB - Spatial, density, and temporal resolution of the dynamic spatial reconstructor (DSR), a multiple X-ray source, high speed, computed tomography scanning system, are evaluated. Hole-pair resolution was evaluated in a stationary phantom surrounded with air, 15 cm of water, or 20 cm of water. Temporal resolution was evaluated by rotation of one of the resolution phantoms during the scan, and with a balloon inflated to a known volume and at a known rate to approximate a typical left ventricular chamber volume and filling rate. These studies confirmed that the spatial resolution is essentially the same in the transverse and axial directions, and that retrospective manipulation of the image data is important for maximization of spatial and density resolution in any structure under examination by obtaining a tradeoff with partial-volume and motion-blurring effects. Maximum spatial resolution in the scanned volume was shown, under ideal conditions, to be greater than five hole pairs per centimeter. Under conditions of intravenous injection of contrast agent, the resolution of blood vessels in an experimental animal approximately 25 kg in weight is expected to be on the order of three hole pairs per centimeter; and in an adult human weighing approximately 60 kg, a resolution of about two hole pairs per centimeter is to be expected.
KW - Computed tomography
KW - Dynamic spatial reconstruction
KW - Resolution
UR - http://www.scopus.com/inward/record.url?scp=0020384988&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0020384988&partnerID=8YFLogxK
U2 - 10.1097/00004728-198212000-00015
DO - 10.1097/00004728-198212000-00015
M3 - Article
C2 - 7174931
AN - SCOPUS:0020384988
SN - 0363-8715
VL - 6
SP - 1138
EP - 1147
JO - Journal of Computer Assisted Tomography
JF - Journal of Computer Assisted Tomography
IS - 6
ER -