The value of 24-hour images after rest thallium injection

H. M. Wagdy, T. F. Christian, T. D. Miller, Raymond J Gibbons

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

Rest 201Tl imaging has been used for detecting viability, but the ideal timing for imaging after injection to maximally estimate viability is not well established. Thirty patients with fixed or incompletely reversible defects on 4 h redistribution SPECT imaging after thallium rest injection underwent 24 h imaging. Global redistribution was subjectively rated none, minimal or meaningful by two experienced observers. Fourteen patients had no meaningful redistribution at either 4 h or 24 h. Ten patients had meaningful redistribution at 4 h only. Six patients had no meaningful redistribution at 4 h but did at 24 h. Defect size was quantified using a 70% threshold. For the total group, defect size was smaller at 4 h compared to immediate imaging (38 ± 18% vs 41 ± 19%, P = 0.06) and smaller still at 24 h (36 ± 16% vs 38 ± 18%, P = 0.02). Later (24 h) redistribution images detected additional redistribution in 30% of the patients who did not have meaningful redistribution on early (4 h) images, and in 8% of the segments which were abnormal at 4 h. It is concluded that, in patients who have incompletely reversible defects on early redistribution imaging at 4 h, late redistribution imaging after 24 h will demonstrate additional redistribution in 30% of the patients.

Original languageEnglish (US)
Pages (from-to)629-637
Number of pages9
JournalNuclear Medicine Communications
Volume23
Issue number7
DOIs
StatePublished - 2002

Fingerprint

Thallium
Injections
Single-Photon Emission-Computed Tomography

Keywords

  • Coronary artery disease
  • Thallium
  • Viability

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology

Cite this

The value of 24-hour images after rest thallium injection. / Wagdy, H. M.; Christian, T. F.; Miller, T. D.; Gibbons, Raymond J.

In: Nuclear Medicine Communications, Vol. 23, No. 7, 2002, p. 629-637.

Research output: Contribution to journalArticle

Wagdy, H. M. ; Christian, T. F. ; Miller, T. D. ; Gibbons, Raymond J. / The value of 24-hour images after rest thallium injection. In: Nuclear Medicine Communications. 2002 ; Vol. 23, No. 7. pp. 629-637.
@article{334ae77e791b452287c2d3ed18172cf2,
title = "The value of 24-hour images after rest thallium injection",
abstract = "Rest 201Tl imaging has been used for detecting viability, but the ideal timing for imaging after injection to maximally estimate viability is not well established. Thirty patients with fixed or incompletely reversible defects on 4 h redistribution SPECT imaging after thallium rest injection underwent 24 h imaging. Global redistribution was subjectively rated none, minimal or meaningful by two experienced observers. Fourteen patients had no meaningful redistribution at either 4 h or 24 h. Ten patients had meaningful redistribution at 4 h only. Six patients had no meaningful redistribution at 4 h but did at 24 h. Defect size was quantified using a 70{\%} threshold. For the total group, defect size was smaller at 4 h compared to immediate imaging (38 ± 18{\%} vs 41 ± 19{\%}, P = 0.06) and smaller still at 24 h (36 ± 16{\%} vs 38 ± 18{\%}, P = 0.02). Later (24 h) redistribution images detected additional redistribution in 30{\%} of the patients who did not have meaningful redistribution on early (4 h) images, and in 8{\%} of the segments which were abnormal at 4 h. It is concluded that, in patients who have incompletely reversible defects on early redistribution imaging at 4 h, late redistribution imaging after 24 h will demonstrate additional redistribution in 30{\%} of the patients.",
keywords = "Coronary artery disease, Thallium, Viability",
author = "Wagdy, {H. M.} and Christian, {T. F.} and Miller, {T. D.} and Gibbons, {Raymond J}",
year = "2002",
doi = "10.1097/00006231-200207000-00007",
language = "English (US)",
volume = "23",
pages = "629--637",
journal = "Nuclear Medicine Communications",
issn = "0143-3636",
publisher = "Lippincott Williams and Wilkins",
number = "7",

}

TY - JOUR

T1 - The value of 24-hour images after rest thallium injection

AU - Wagdy, H. M.

AU - Christian, T. F.

AU - Miller, T. D.

AU - Gibbons, Raymond J

PY - 2002

Y1 - 2002

N2 - Rest 201Tl imaging has been used for detecting viability, but the ideal timing for imaging after injection to maximally estimate viability is not well established. Thirty patients with fixed or incompletely reversible defects on 4 h redistribution SPECT imaging after thallium rest injection underwent 24 h imaging. Global redistribution was subjectively rated none, minimal or meaningful by two experienced observers. Fourteen patients had no meaningful redistribution at either 4 h or 24 h. Ten patients had meaningful redistribution at 4 h only. Six patients had no meaningful redistribution at 4 h but did at 24 h. Defect size was quantified using a 70% threshold. For the total group, defect size was smaller at 4 h compared to immediate imaging (38 ± 18% vs 41 ± 19%, P = 0.06) and smaller still at 24 h (36 ± 16% vs 38 ± 18%, P = 0.02). Later (24 h) redistribution images detected additional redistribution in 30% of the patients who did not have meaningful redistribution on early (4 h) images, and in 8% of the segments which were abnormal at 4 h. It is concluded that, in patients who have incompletely reversible defects on early redistribution imaging at 4 h, late redistribution imaging after 24 h will demonstrate additional redistribution in 30% of the patients.

AB - Rest 201Tl imaging has been used for detecting viability, but the ideal timing for imaging after injection to maximally estimate viability is not well established. Thirty patients with fixed or incompletely reversible defects on 4 h redistribution SPECT imaging after thallium rest injection underwent 24 h imaging. Global redistribution was subjectively rated none, minimal or meaningful by two experienced observers. Fourteen patients had no meaningful redistribution at either 4 h or 24 h. Ten patients had meaningful redistribution at 4 h only. Six patients had no meaningful redistribution at 4 h but did at 24 h. Defect size was quantified using a 70% threshold. For the total group, defect size was smaller at 4 h compared to immediate imaging (38 ± 18% vs 41 ± 19%, P = 0.06) and smaller still at 24 h (36 ± 16% vs 38 ± 18%, P = 0.02). Later (24 h) redistribution images detected additional redistribution in 30% of the patients who did not have meaningful redistribution on early (4 h) images, and in 8% of the segments which were abnormal at 4 h. It is concluded that, in patients who have incompletely reversible defects on early redistribution imaging at 4 h, late redistribution imaging after 24 h will demonstrate additional redistribution in 30% of the patients.

KW - Coronary artery disease

KW - Thallium

KW - Viability

UR - http://www.scopus.com/inward/record.url?scp=0036301603&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036301603&partnerID=8YFLogxK

U2 - 10.1097/00006231-200207000-00007

DO - 10.1097/00006231-200207000-00007

M3 - Article

C2 - 12089485

AN - SCOPUS:0036301603

VL - 23

SP - 629

EP - 637

JO - Nuclear Medicine Communications

JF - Nuclear Medicine Communications

SN - 0143-3636

IS - 7

ER -