The utility of hemodynamic measurements acquired by pulmonary artery catheterization

Gamal Mostafa, Muthuswamy Kumar, Judd Schlotthauer, Michael J. Murray

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

BACKGROUND: Concerns about the utility of pulmonary artery catheters (PAC) stimulated us to assess the impact of one of the parameters measured by the PAC, the pulmonary capillary wedge pressure (PCWP), on our clinical practice. METHODS: The PCWP was recorded at 4- to 6-hour intervals on 50 patients for the first 48 hours following aortic aneurysm repair. We then reviewed the patients' records looking for evidence that the PCWP measurements were used to guide therapy. For the purpose of the study, we anticipated the administration of diuretics for PCWP ≤18 mm Hg and volume resuscitation for PCWP ≤8 mm Hg. Data were correlated using Pearson rank correlation coefficient using a P <0.05 to determine statistical significance. RESULTS: Patients with PCWPs <8 mm Hg were more likely to be treated with volume resuscitation (P <0.05). There was no other correlation between PCWP measurements and fluid or pharmacologic management. CONCLUSIONS: Data derived from the PAC are infrequently used to guide therapy in patients who undergo abdominal aortic reconstructive surgery.

Original languageEnglish (US)
Pages (from-to)293-296
Number of pages4
JournalAmerican Journal of Surgery
Volume175
Issue number4
DOIs
StatePublished - Apr 1998

Fingerprint

Swan-Ganz Catheterization
Pulmonary Wedge Pressure
Hemodynamics
Pulmonary Artery
Catheters
Resuscitation
Reconstructive Surgical Procedures
Aortic Aneurysm
Diuretics
Therapeutics

ASJC Scopus subject areas

  • Surgery

Cite this

The utility of hemodynamic measurements acquired by pulmonary artery catheterization. / Mostafa, Gamal; Kumar, Muthuswamy; Schlotthauer, Judd; Murray, Michael J.

In: American Journal of Surgery, Vol. 175, No. 4, 04.1998, p. 293-296.

Research output: Contribution to journalArticle

Mostafa, Gamal ; Kumar, Muthuswamy ; Schlotthauer, Judd ; Murray, Michael J. / The utility of hemodynamic measurements acquired by pulmonary artery catheterization. In: American Journal of Surgery. 1998 ; Vol. 175, No. 4. pp. 293-296.
@article{a04f7355b9244d01b6789a5e3ff2bd40,
title = "The utility of hemodynamic measurements acquired by pulmonary artery catheterization",
abstract = "BACKGROUND: Concerns about the utility of pulmonary artery catheters (PAC) stimulated us to assess the impact of one of the parameters measured by the PAC, the pulmonary capillary wedge pressure (PCWP), on our clinical practice. METHODS: The PCWP was recorded at 4- to 6-hour intervals on 50 patients for the first 48 hours following aortic aneurysm repair. We then reviewed the patients' records looking for evidence that the PCWP measurements were used to guide therapy. For the purpose of the study, we anticipated the administration of diuretics for PCWP ≤18 mm Hg and volume resuscitation for PCWP ≤8 mm Hg. Data were correlated using Pearson rank correlation coefficient using a P <0.05 to determine statistical significance. RESULTS: Patients with PCWPs <8 mm Hg were more likely to be treated with volume resuscitation (P <0.05). There was no other correlation between PCWP measurements and fluid or pharmacologic management. CONCLUSIONS: Data derived from the PAC are infrequently used to guide therapy in patients who undergo abdominal aortic reconstructive surgery.",
author = "Gamal Mostafa and Muthuswamy Kumar and Judd Schlotthauer and Murray, {Michael J.}",
year = "1998",
month = "4",
doi = "10.1016/S0002-9610(98)00015-4",
language = "English (US)",
volume = "175",
pages = "293--296",
journal = "American Journal of Surgery",
issn = "0002-9610",
publisher = "Elsevier Inc.",
number = "4",

}

TY - JOUR

T1 - The utility of hemodynamic measurements acquired by pulmonary artery catheterization

AU - Mostafa, Gamal

AU - Kumar, Muthuswamy

AU - Schlotthauer, Judd

AU - Murray, Michael J.

PY - 1998/4

Y1 - 1998/4

N2 - BACKGROUND: Concerns about the utility of pulmonary artery catheters (PAC) stimulated us to assess the impact of one of the parameters measured by the PAC, the pulmonary capillary wedge pressure (PCWP), on our clinical practice. METHODS: The PCWP was recorded at 4- to 6-hour intervals on 50 patients for the first 48 hours following aortic aneurysm repair. We then reviewed the patients' records looking for evidence that the PCWP measurements were used to guide therapy. For the purpose of the study, we anticipated the administration of diuretics for PCWP ≤18 mm Hg and volume resuscitation for PCWP ≤8 mm Hg. Data were correlated using Pearson rank correlation coefficient using a P <0.05 to determine statistical significance. RESULTS: Patients with PCWPs <8 mm Hg were more likely to be treated with volume resuscitation (P <0.05). There was no other correlation between PCWP measurements and fluid or pharmacologic management. CONCLUSIONS: Data derived from the PAC are infrequently used to guide therapy in patients who undergo abdominal aortic reconstructive surgery.

AB - BACKGROUND: Concerns about the utility of pulmonary artery catheters (PAC) stimulated us to assess the impact of one of the parameters measured by the PAC, the pulmonary capillary wedge pressure (PCWP), on our clinical practice. METHODS: The PCWP was recorded at 4- to 6-hour intervals on 50 patients for the first 48 hours following aortic aneurysm repair. We then reviewed the patients' records looking for evidence that the PCWP measurements were used to guide therapy. For the purpose of the study, we anticipated the administration of diuretics for PCWP ≤18 mm Hg and volume resuscitation for PCWP ≤8 mm Hg. Data were correlated using Pearson rank correlation coefficient using a P <0.05 to determine statistical significance. RESULTS: Patients with PCWPs <8 mm Hg were more likely to be treated with volume resuscitation (P <0.05). There was no other correlation between PCWP measurements and fluid or pharmacologic management. CONCLUSIONS: Data derived from the PAC are infrequently used to guide therapy in patients who undergo abdominal aortic reconstructive surgery.

UR - http://www.scopus.com/inward/record.url?scp=0032054106&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032054106&partnerID=8YFLogxK

U2 - 10.1016/S0002-9610(98)00015-4

DO - 10.1016/S0002-9610(98)00015-4

M3 - Article

C2 - 9568654

AN - SCOPUS:0032054106

VL - 175

SP - 293

EP - 296

JO - American Journal of Surgery

JF - American Journal of Surgery

SN - 0002-9610

IS - 4

ER -