The relationship of vascularity and water content to tensile strength in a patellar tendon replacement of the anterior cruciate in dogs

E. G. McFarland, B. F. Morrey, K. N. An, M. B. Wood

Research output: Contribution to journalArticle

84 Citations (Scopus)

Abstract

The methods and materials for ACL reconstruction are important issues for the practicing orthopaedic surgeon. In this study a model was developed to study the biological and biomechanical characteristics of a patellar tendon autograft used for ACL reconstruciton. Specifically it was hypothesized that since vascularity of these grafts reflects their 'healthiness,' strength and vascularity should be inversely related in the early period after implantation. Using an over the top technique, a patellar tendon graft was placed in three groups of dogs and studied at 37, 57, and 120 days. Vascularity of the grafts was measured using technetium-tagged red blood cells, and percent water by weight was determined by dessication. Tensile testing to failure was performed using an MTS machine. The grafts became more vascular, more hydrated, less stiff, and less strong (by 4 weeks) than controls. By 16 weeks the vascular response was subsiding but the grafts remained only 40% as strong as controls. Percent water increased significantly over controls for all time periods. Decrease in strength correlated poorly with vascularity but correlated well with increase in percent water. These findings suggest that the change in strength of an intraarticular ACL replacement relates more to a basic rearrangement of its collagen-ground substance relationships, and that vascularity may reflect the inflammatory response bringing about these changes. The model developed in this study serves as a basis for further studies, and the findings reveal important information about the behavior of ACL grafting materials.

Original languageEnglish (US)
Pages (from-to)436-448
Number of pages13
JournalAmerican Journal of Sports Medicine
Volume14
Issue number6
StatePublished - 1986

Fingerprint

Patellar Ligament
Tensile Strength
Dogs
Transplants
Water
Blood Vessels
Desiccation
Technetium
Autografts
Collagen
Erythrocytes
Weights and Measures

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine
  • Public Health, Environmental and Occupational Health
  • Physical Therapy, Sports Therapy and Rehabilitation

Cite this

The relationship of vascularity and water content to tensile strength in a patellar tendon replacement of the anterior cruciate in dogs. / McFarland, E. G.; Morrey, B. F.; An, K. N.; Wood, M. B.

In: American Journal of Sports Medicine, Vol. 14, No. 6, 1986, p. 436-448.

Research output: Contribution to journalArticle

@article{b2cb2881d5014a0ab41af57ad9f29efd,
title = "The relationship of vascularity and water content to tensile strength in a patellar tendon replacement of the anterior cruciate in dogs",
abstract = "The methods and materials for ACL reconstruction are important issues for the practicing orthopaedic surgeon. In this study a model was developed to study the biological and biomechanical characteristics of a patellar tendon autograft used for ACL reconstruciton. Specifically it was hypothesized that since vascularity of these grafts reflects their 'healthiness,' strength and vascularity should be inversely related in the early period after implantation. Using an over the top technique, a patellar tendon graft was placed in three groups of dogs and studied at 37, 57, and 120 days. Vascularity of the grafts was measured using technetium-tagged red blood cells, and percent water by weight was determined by dessication. Tensile testing to failure was performed using an MTS machine. The grafts became more vascular, more hydrated, less stiff, and less strong (by 4 weeks) than controls. By 16 weeks the vascular response was subsiding but the grafts remained only 40{\%} as strong as controls. Percent water increased significantly over controls for all time periods. Decrease in strength correlated poorly with vascularity but correlated well with increase in percent water. These findings suggest that the change in strength of an intraarticular ACL replacement relates more to a basic rearrangement of its collagen-ground substance relationships, and that vascularity may reflect the inflammatory response bringing about these changes. The model developed in this study serves as a basis for further studies, and the findings reveal important information about the behavior of ACL grafting materials.",
author = "McFarland, {E. G.} and Morrey, {B. F.} and An, {K. N.} and Wood, {M. B.}",
year = "1986",
language = "English (US)",
volume = "14",
pages = "436--448",
journal = "American Journal of Sports Medicine",
issn = "0363-5465",
publisher = "SAGE Publications Inc.",
number = "6",

}

TY - JOUR

T1 - The relationship of vascularity and water content to tensile strength in a patellar tendon replacement of the anterior cruciate in dogs

AU - McFarland, E. G.

AU - Morrey, B. F.

AU - An, K. N.

AU - Wood, M. B.

PY - 1986

Y1 - 1986

N2 - The methods and materials for ACL reconstruction are important issues for the practicing orthopaedic surgeon. In this study a model was developed to study the biological and biomechanical characteristics of a patellar tendon autograft used for ACL reconstruciton. Specifically it was hypothesized that since vascularity of these grafts reflects their 'healthiness,' strength and vascularity should be inversely related in the early period after implantation. Using an over the top technique, a patellar tendon graft was placed in three groups of dogs and studied at 37, 57, and 120 days. Vascularity of the grafts was measured using technetium-tagged red blood cells, and percent water by weight was determined by dessication. Tensile testing to failure was performed using an MTS machine. The grafts became more vascular, more hydrated, less stiff, and less strong (by 4 weeks) than controls. By 16 weeks the vascular response was subsiding but the grafts remained only 40% as strong as controls. Percent water increased significantly over controls for all time periods. Decrease in strength correlated poorly with vascularity but correlated well with increase in percent water. These findings suggest that the change in strength of an intraarticular ACL replacement relates more to a basic rearrangement of its collagen-ground substance relationships, and that vascularity may reflect the inflammatory response bringing about these changes. The model developed in this study serves as a basis for further studies, and the findings reveal important information about the behavior of ACL grafting materials.

AB - The methods and materials for ACL reconstruction are important issues for the practicing orthopaedic surgeon. In this study a model was developed to study the biological and biomechanical characteristics of a patellar tendon autograft used for ACL reconstruciton. Specifically it was hypothesized that since vascularity of these grafts reflects their 'healthiness,' strength and vascularity should be inversely related in the early period after implantation. Using an over the top technique, a patellar tendon graft was placed in three groups of dogs and studied at 37, 57, and 120 days. Vascularity of the grafts was measured using technetium-tagged red blood cells, and percent water by weight was determined by dessication. Tensile testing to failure was performed using an MTS machine. The grafts became more vascular, more hydrated, less stiff, and less strong (by 4 weeks) than controls. By 16 weeks the vascular response was subsiding but the grafts remained only 40% as strong as controls. Percent water increased significantly over controls for all time periods. Decrease in strength correlated poorly with vascularity but correlated well with increase in percent water. These findings suggest that the change in strength of an intraarticular ACL replacement relates more to a basic rearrangement of its collagen-ground substance relationships, and that vascularity may reflect the inflammatory response bringing about these changes. The model developed in this study serves as a basis for further studies, and the findings reveal important information about the behavior of ACL grafting materials.

UR - http://www.scopus.com/inward/record.url?scp=0022980333&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0022980333&partnerID=8YFLogxK

M3 - Article

C2 - 3541655

AN - SCOPUS:0022980333

VL - 14

SP - 436

EP - 448

JO - American Journal of Sports Medicine

JF - American Journal of Sports Medicine

SN - 0363-5465

IS - 6

ER -