The musculoskeletal loading profile of the thumb during pipetting based on tendon displacement

John Z. Wu, Erik W. Sinsel, Justin F. Shroyer, Daniel E. Welcome, Kristin D Zhao, Kai Nan An, Frank L. Buczek

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Strong evidence indicates that highly repetitive manual work is associated with the development of upper extremity musculoskeletal disorders (MSDs). One of the occupational activities that involves highly repetitive and forceful hand work is manual pipetting in chemical or biological laboratories. In the current study, we quantified tendon displacement as a parameter to assess the cumulative loading exposure of the musculoskeletal system in the thumb during pipetting. The maximal tendon displacement was found in the flexor pollicis longus (FPL) tendon. Assuming that subjects' pipetting rates were maintained constant during a period of 1. h, the average accumulated tendon displacement in the FPL reached 29. m, which is in the lower range of those observed in other occupational activities, such as typing and nail gun operations. Our results showed that tendon displacement data contain relatively small standard deviations, despite high variances in thumb kinematics, suggesting that the tendon displacements may be useful in evaluating the musculoskeletal loading profile.

Original languageEnglish (US)
Pages (from-to)1801-1810
Number of pages10
JournalMedical Engineering and Physics
Volume35
Issue number12
DOIs
StatePublished - Dec 2013

Fingerprint

Thumb
Tendons
Musculoskeletal system
Musculoskeletal System
Nails
Firearms
Biomechanical Phenomena
Upper Extremity
Kinematics
Hand

Keywords

  • Inverse dynamics
  • Modeling
  • Muscle-tendon force
  • Pipette
  • Thumb

ASJC Scopus subject areas

  • Biomedical Engineering
  • Biophysics

Cite this

The musculoskeletal loading profile of the thumb during pipetting based on tendon displacement. / Wu, John Z.; Sinsel, Erik W.; Shroyer, Justin F.; Welcome, Daniel E.; Zhao, Kristin D; An, Kai Nan; Buczek, Frank L.

In: Medical Engineering and Physics, Vol. 35, No. 12, 12.2013, p. 1801-1810.

Research output: Contribution to journalArticle

Wu, John Z. ; Sinsel, Erik W. ; Shroyer, Justin F. ; Welcome, Daniel E. ; Zhao, Kristin D ; An, Kai Nan ; Buczek, Frank L. / The musculoskeletal loading profile of the thumb during pipetting based on tendon displacement. In: Medical Engineering and Physics. 2013 ; Vol. 35, No. 12. pp. 1801-1810.
@article{7cc9f0c09de44f509e8692e3656a3a35,
title = "The musculoskeletal loading profile of the thumb during pipetting based on tendon displacement",
abstract = "Strong evidence indicates that highly repetitive manual work is associated with the development of upper extremity musculoskeletal disorders (MSDs). One of the occupational activities that involves highly repetitive and forceful hand work is manual pipetting in chemical or biological laboratories. In the current study, we quantified tendon displacement as a parameter to assess the cumulative loading exposure of the musculoskeletal system in the thumb during pipetting. The maximal tendon displacement was found in the flexor pollicis longus (FPL) tendon. Assuming that subjects' pipetting rates were maintained constant during a period of 1. h, the average accumulated tendon displacement in the FPL reached 29. m, which is in the lower range of those observed in other occupational activities, such as typing and nail gun operations. Our results showed that tendon displacement data contain relatively small standard deviations, despite high variances in thumb kinematics, suggesting that the tendon displacements may be useful in evaluating the musculoskeletal loading profile.",
keywords = "Inverse dynamics, Modeling, Muscle-tendon force, Pipette, Thumb",
author = "Wu, {John Z.} and Sinsel, {Erik W.} and Shroyer, {Justin F.} and Welcome, {Daniel E.} and Zhao, {Kristin D} and An, {Kai Nan} and Buczek, {Frank L.}",
year = "2013",
month = "12",
doi = "10.1016/j.medengphy.2013.08.004",
language = "English (US)",
volume = "35",
pages = "1801--1810",
journal = "Medical Engineering and Physics",
issn = "1350-4533",
publisher = "Elsevier BV",
number = "12",

}

TY - JOUR

T1 - The musculoskeletal loading profile of the thumb during pipetting based on tendon displacement

AU - Wu, John Z.

AU - Sinsel, Erik W.

AU - Shroyer, Justin F.

AU - Welcome, Daniel E.

AU - Zhao, Kristin D

AU - An, Kai Nan

AU - Buczek, Frank L.

PY - 2013/12

Y1 - 2013/12

N2 - Strong evidence indicates that highly repetitive manual work is associated with the development of upper extremity musculoskeletal disorders (MSDs). One of the occupational activities that involves highly repetitive and forceful hand work is manual pipetting in chemical or biological laboratories. In the current study, we quantified tendon displacement as a parameter to assess the cumulative loading exposure of the musculoskeletal system in the thumb during pipetting. The maximal tendon displacement was found in the flexor pollicis longus (FPL) tendon. Assuming that subjects' pipetting rates were maintained constant during a period of 1. h, the average accumulated tendon displacement in the FPL reached 29. m, which is in the lower range of those observed in other occupational activities, such as typing and nail gun operations. Our results showed that tendon displacement data contain relatively small standard deviations, despite high variances in thumb kinematics, suggesting that the tendon displacements may be useful in evaluating the musculoskeletal loading profile.

AB - Strong evidence indicates that highly repetitive manual work is associated with the development of upper extremity musculoskeletal disorders (MSDs). One of the occupational activities that involves highly repetitive and forceful hand work is manual pipetting in chemical or biological laboratories. In the current study, we quantified tendon displacement as a parameter to assess the cumulative loading exposure of the musculoskeletal system in the thumb during pipetting. The maximal tendon displacement was found in the flexor pollicis longus (FPL) tendon. Assuming that subjects' pipetting rates were maintained constant during a period of 1. h, the average accumulated tendon displacement in the FPL reached 29. m, which is in the lower range of those observed in other occupational activities, such as typing and nail gun operations. Our results showed that tendon displacement data contain relatively small standard deviations, despite high variances in thumb kinematics, suggesting that the tendon displacements may be useful in evaluating the musculoskeletal loading profile.

KW - Inverse dynamics

KW - Modeling

KW - Muscle-tendon force

KW - Pipette

KW - Thumb

UR - http://www.scopus.com/inward/record.url?scp=84889571862&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84889571862&partnerID=8YFLogxK

U2 - 10.1016/j.medengphy.2013.08.004

DO - 10.1016/j.medengphy.2013.08.004

M3 - Article

VL - 35

SP - 1801

EP - 1810

JO - Medical Engineering and Physics

JF - Medical Engineering and Physics

SN - 1350-4533

IS - 12

ER -