The effect of the orientation of the radial head on the kinematics of the ulnohumeral joint and force transmission through the radiocapitellar joint

R. P. van Riet, F. Van Glabbeek, J. A. Baumfeld, P. G. Neale, B. F. Morrey, S. W. O'Driscoll, K. N. An

Research output: Contribution to journalArticle

30 Citations (Scopus)

Abstract

Background. The treatment of radial head fractures that are not amenable to an open reduction and internal fixation, remains to be a difficult issue. A potential problem with prosthetic replacement of the radial head is the shape of current radial head prostheses. The purpose of this study was to determine the effect of the shape of the radial head on kinematics and load transfer of the elbow. Methods. Kinematics of the elbow and radiocapitellar force transmission were measured in 6 fresh frozen upper extremities. The effect of radial head shape was tested by rotating the head 90°, with a custom-made 'native' radial head prosthesis. 3-D spatial orientation of the ulna showed an average difference in ulnohumeral laxity, between the nominal and 90° conditions, of 0.1° throughout the arc of motion with neutral forearm rotation (maximum: 2°). Findings. We found an average difference in ulnar axial rotation, of 0.1° (maximum: 1.9°). No differences showed statistical significance. Radiohumeral joint force was measured and maximally showed a 32 times increase of force in the altered shape conditions. Interpretation. Our results show that the kinematics of the elbow was not affected by altering the shape of the radial head, but it did adversely affect the forces in the radiohumeral joint. This could possibly generate degenerative changes in the elbow.

Original languageEnglish (US)
Pages (from-to)554-559
Number of pages6
JournalClinical Biomechanics
Volume21
Issue number6
DOIs
StatePublished - Jul 2006

Fingerprint

Elbow
Biomechanical Phenomena
Joints
Prostheses and Implants
Ulna
Forearm
Upper Extremity
Head

Keywords

  • Force
  • Kinematics
  • Radial head

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine

Cite this

The effect of the orientation of the radial head on the kinematics of the ulnohumeral joint and force transmission through the radiocapitellar joint. / van Riet, R. P.; Van Glabbeek, F.; Baumfeld, J. A.; Neale, P. G.; Morrey, B. F.; O'Driscoll, S. W.; An, K. N.

In: Clinical Biomechanics, Vol. 21, No. 6, 07.2006, p. 554-559.

Research output: Contribution to journalArticle

van Riet, R. P. ; Van Glabbeek, F. ; Baumfeld, J. A. ; Neale, P. G. ; Morrey, B. F. ; O'Driscoll, S. W. ; An, K. N. / The effect of the orientation of the radial head on the kinematics of the ulnohumeral joint and force transmission through the radiocapitellar joint. In: Clinical Biomechanics. 2006 ; Vol. 21, No. 6. pp. 554-559.
@article{05573d8220da4285aa25659b7f31f01d,
title = "The effect of the orientation of the radial head on the kinematics of the ulnohumeral joint and force transmission through the radiocapitellar joint",
abstract = "Background. The treatment of radial head fractures that are not amenable to an open reduction and internal fixation, remains to be a difficult issue. A potential problem with prosthetic replacement of the radial head is the shape of current radial head prostheses. The purpose of this study was to determine the effect of the shape of the radial head on kinematics and load transfer of the elbow. Methods. Kinematics of the elbow and radiocapitellar force transmission were measured in 6 fresh frozen upper extremities. The effect of radial head shape was tested by rotating the head 90°, with a custom-made 'native' radial head prosthesis. 3-D spatial orientation of the ulna showed an average difference in ulnohumeral laxity, between the nominal and 90° conditions, of 0.1° throughout the arc of motion with neutral forearm rotation (maximum: 2°). Findings. We found an average difference in ulnar axial rotation, of 0.1° (maximum: 1.9°). No differences showed statistical significance. Radiohumeral joint force was measured and maximally showed a 32 times increase of force in the altered shape conditions. Interpretation. Our results show that the kinematics of the elbow was not affected by altering the shape of the radial head, but it did adversely affect the forces in the radiohumeral joint. This could possibly generate degenerative changes in the elbow.",
keywords = "Force, Kinematics, Radial head",
author = "{van Riet}, {R. P.} and {Van Glabbeek}, F. and Baumfeld, {J. A.} and Neale, {P. G.} and Morrey, {B. F.} and O'Driscoll, {S. W.} and An, {K. N.}",
year = "2006",
month = "7",
doi = "10.1016/j.clinbiomech.2006.01.006",
language = "English (US)",
volume = "21",
pages = "554--559",
journal = "Clinical Biomechanics",
issn = "0268-0033",
publisher = "Elsevier Limited",
number = "6",

}

TY - JOUR

T1 - The effect of the orientation of the radial head on the kinematics of the ulnohumeral joint and force transmission through the radiocapitellar joint

AU - van Riet, R. P.

AU - Van Glabbeek, F.

AU - Baumfeld, J. A.

AU - Neale, P. G.

AU - Morrey, B. F.

AU - O'Driscoll, S. W.

AU - An, K. N.

PY - 2006/7

Y1 - 2006/7

N2 - Background. The treatment of radial head fractures that are not amenable to an open reduction and internal fixation, remains to be a difficult issue. A potential problem with prosthetic replacement of the radial head is the shape of current radial head prostheses. The purpose of this study was to determine the effect of the shape of the radial head on kinematics and load transfer of the elbow. Methods. Kinematics of the elbow and radiocapitellar force transmission were measured in 6 fresh frozen upper extremities. The effect of radial head shape was tested by rotating the head 90°, with a custom-made 'native' radial head prosthesis. 3-D spatial orientation of the ulna showed an average difference in ulnohumeral laxity, between the nominal and 90° conditions, of 0.1° throughout the arc of motion with neutral forearm rotation (maximum: 2°). Findings. We found an average difference in ulnar axial rotation, of 0.1° (maximum: 1.9°). No differences showed statistical significance. Radiohumeral joint force was measured and maximally showed a 32 times increase of force in the altered shape conditions. Interpretation. Our results show that the kinematics of the elbow was not affected by altering the shape of the radial head, but it did adversely affect the forces in the radiohumeral joint. This could possibly generate degenerative changes in the elbow.

AB - Background. The treatment of radial head fractures that are not amenable to an open reduction and internal fixation, remains to be a difficult issue. A potential problem with prosthetic replacement of the radial head is the shape of current radial head prostheses. The purpose of this study was to determine the effect of the shape of the radial head on kinematics and load transfer of the elbow. Methods. Kinematics of the elbow and radiocapitellar force transmission were measured in 6 fresh frozen upper extremities. The effect of radial head shape was tested by rotating the head 90°, with a custom-made 'native' radial head prosthesis. 3-D spatial orientation of the ulna showed an average difference in ulnohumeral laxity, between the nominal and 90° conditions, of 0.1° throughout the arc of motion with neutral forearm rotation (maximum: 2°). Findings. We found an average difference in ulnar axial rotation, of 0.1° (maximum: 1.9°). No differences showed statistical significance. Radiohumeral joint force was measured and maximally showed a 32 times increase of force in the altered shape conditions. Interpretation. Our results show that the kinematics of the elbow was not affected by altering the shape of the radial head, but it did adversely affect the forces in the radiohumeral joint. This could possibly generate degenerative changes in the elbow.

KW - Force

KW - Kinematics

KW - Radial head

UR - http://www.scopus.com/inward/record.url?scp=33744511726&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33744511726&partnerID=8YFLogxK

U2 - 10.1016/j.clinbiomech.2006.01.006

DO - 10.1016/j.clinbiomech.2006.01.006

M3 - Article

C2 - 16530305

AN - SCOPUS:33744511726

VL - 21

SP - 554

EP - 559

JO - Clinical Biomechanics

JF - Clinical Biomechanics

SN - 0268-0033

IS - 6

ER -