The dual tracer time-varying volume method for measuring hepatic glucose release on nonsteady state

theoretical and simulation results

Andrea Caumo, Antonio Zerman, Robert Rizza, Claudio Cobelli

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Measurement of hepatic glucose release in nonsteady state is difficult and experimental approaches have been developed in order to circumvent Steele's model inadequacy. Recently, a resurgence of interest in the time-varying volume method developed by Issekutz has taken place. Issekutz's approach assumes that the volume of Steele's model is not constant but time-varying and that its time course can be measured by infusing two tracers with different patterns. The time-varying volume is then substituted into Steele's equation and hepatic glucose release is estimated. The aim of this study was to analyze some basic aspects of Issekutz's method and to determine the accuracy of its estimate of hepatic glucose release. A theoretical analysis showed that the time-varying volume measured by Issekutz's approach is not unique but depends on the format of administration of the two tracers. In addition, such a volume allows an accurate estimate of hepatic glucose release if one of the two tracers is infused in such a way that its specific activity is maintained perfectly constant during the experiment. Since it is impossible to achieve a perfect clamp of specific activity, we also evaluated the performance of Issekutz's approach in more realistic experimental conditions which were reproduced by resorting to computer simulation. We simulated a euglycaemic clamp with insulin rising from basal to a plateau of approximately 40 μU/ml and then returning to basal. Nonsteady-state glucose kinetics were described by a previously validated two-compartment model while the time course of hepatic glucose release was derived from the literature. Both noise-free and noisy experimental conditions were simulated. We showed that the degree of accuracy of Issekutz's approach is very good and better than the one associated with the hot-ginf method. On the other hand, the major problem with Issekutz's approach is the sensitivity of the volume estimate tot he measurement noise, which may limit its applicability in practice. In conclusion, we elucidated the theoretical grounds of Issekutz's approach and assessed its performance during nonsteady state in a realistic scenario using computer simulation.

Original languageEnglish (US)
Pages (from-to)243-267
Number of pages25
JournalComputer Methods and Programs in Biomedicine
Volume41
Issue number3-4
DOIs
StatePublished - 1994

Fingerprint

Glucose
Liver
Clamping devices
Computer Simulation
Noise
Glucose Clamp Technique
Insulin
Computer simulation
Kinetics
Experiments

Keywords

  • Glucose kinetics
  • hepatic glucose release
  • Mathematical model
  • Nonsteady state
  • Simulation
  • Tracer kinetics

ASJC Scopus subject areas

  • Software

Cite this

The dual tracer time-varying volume method for measuring hepatic glucose release on nonsteady state : theoretical and simulation results. / Caumo, Andrea; Zerman, Antonio; Rizza, Robert; Cobelli, Claudio.

In: Computer Methods and Programs in Biomedicine, Vol. 41, No. 3-4, 1994, p. 243-267.

Research output: Contribution to journalArticle

@article{a188339f3b1343608bdeff194371b51d,
title = "The dual tracer time-varying volume method for measuring hepatic glucose release on nonsteady state: theoretical and simulation results",
abstract = "Measurement of hepatic glucose release in nonsteady state is difficult and experimental approaches have been developed in order to circumvent Steele's model inadequacy. Recently, a resurgence of interest in the time-varying volume method developed by Issekutz has taken place. Issekutz's approach assumes that the volume of Steele's model is not constant but time-varying and that its time course can be measured by infusing two tracers with different patterns. The time-varying volume is then substituted into Steele's equation and hepatic glucose release is estimated. The aim of this study was to analyze some basic aspects of Issekutz's method and to determine the accuracy of its estimate of hepatic glucose release. A theoretical analysis showed that the time-varying volume measured by Issekutz's approach is not unique but depends on the format of administration of the two tracers. In addition, such a volume allows an accurate estimate of hepatic glucose release if one of the two tracers is infused in such a way that its specific activity is maintained perfectly constant during the experiment. Since it is impossible to achieve a perfect clamp of specific activity, we also evaluated the performance of Issekutz's approach in more realistic experimental conditions which were reproduced by resorting to computer simulation. We simulated a euglycaemic clamp with insulin rising from basal to a plateau of approximately 40 μU/ml and then returning to basal. Nonsteady-state glucose kinetics were described by a previously validated two-compartment model while the time course of hepatic glucose release was derived from the literature. Both noise-free and noisy experimental conditions were simulated. We showed that the degree of accuracy of Issekutz's approach is very good and better than the one associated with the hot-ginf method. On the other hand, the major problem with Issekutz's approach is the sensitivity of the volume estimate tot he measurement noise, which may limit its applicability in practice. In conclusion, we elucidated the theoretical grounds of Issekutz's approach and assessed its performance during nonsteady state in a realistic scenario using computer simulation.",
keywords = "Glucose kinetics, hepatic glucose release, Mathematical model, Nonsteady state, Simulation, Tracer kinetics",
author = "Andrea Caumo and Antonio Zerman and Robert Rizza and Claudio Cobelli",
year = "1994",
doi = "10.1016/0169-2607(94)90058-2",
language = "English (US)",
volume = "41",
pages = "243--267",
journal = "Computer Methods and Programs in Biomedicine",
issn = "0169-2607",
publisher = "Elsevier Ireland Ltd",
number = "3-4",

}

TY - JOUR

T1 - The dual tracer time-varying volume method for measuring hepatic glucose release on nonsteady state

T2 - theoretical and simulation results

AU - Caumo, Andrea

AU - Zerman, Antonio

AU - Rizza, Robert

AU - Cobelli, Claudio

PY - 1994

Y1 - 1994

N2 - Measurement of hepatic glucose release in nonsteady state is difficult and experimental approaches have been developed in order to circumvent Steele's model inadequacy. Recently, a resurgence of interest in the time-varying volume method developed by Issekutz has taken place. Issekutz's approach assumes that the volume of Steele's model is not constant but time-varying and that its time course can be measured by infusing two tracers with different patterns. The time-varying volume is then substituted into Steele's equation and hepatic glucose release is estimated. The aim of this study was to analyze some basic aspects of Issekutz's method and to determine the accuracy of its estimate of hepatic glucose release. A theoretical analysis showed that the time-varying volume measured by Issekutz's approach is not unique but depends on the format of administration of the two tracers. In addition, such a volume allows an accurate estimate of hepatic glucose release if one of the two tracers is infused in such a way that its specific activity is maintained perfectly constant during the experiment. Since it is impossible to achieve a perfect clamp of specific activity, we also evaluated the performance of Issekutz's approach in more realistic experimental conditions which were reproduced by resorting to computer simulation. We simulated a euglycaemic clamp with insulin rising from basal to a plateau of approximately 40 μU/ml and then returning to basal. Nonsteady-state glucose kinetics were described by a previously validated two-compartment model while the time course of hepatic glucose release was derived from the literature. Both noise-free and noisy experimental conditions were simulated. We showed that the degree of accuracy of Issekutz's approach is very good and better than the one associated with the hot-ginf method. On the other hand, the major problem with Issekutz's approach is the sensitivity of the volume estimate tot he measurement noise, which may limit its applicability in practice. In conclusion, we elucidated the theoretical grounds of Issekutz's approach and assessed its performance during nonsteady state in a realistic scenario using computer simulation.

AB - Measurement of hepatic glucose release in nonsteady state is difficult and experimental approaches have been developed in order to circumvent Steele's model inadequacy. Recently, a resurgence of interest in the time-varying volume method developed by Issekutz has taken place. Issekutz's approach assumes that the volume of Steele's model is not constant but time-varying and that its time course can be measured by infusing two tracers with different patterns. The time-varying volume is then substituted into Steele's equation and hepatic glucose release is estimated. The aim of this study was to analyze some basic aspects of Issekutz's method and to determine the accuracy of its estimate of hepatic glucose release. A theoretical analysis showed that the time-varying volume measured by Issekutz's approach is not unique but depends on the format of administration of the two tracers. In addition, such a volume allows an accurate estimate of hepatic glucose release if one of the two tracers is infused in such a way that its specific activity is maintained perfectly constant during the experiment. Since it is impossible to achieve a perfect clamp of specific activity, we also evaluated the performance of Issekutz's approach in more realistic experimental conditions which were reproduced by resorting to computer simulation. We simulated a euglycaemic clamp with insulin rising from basal to a plateau of approximately 40 μU/ml and then returning to basal. Nonsteady-state glucose kinetics were described by a previously validated two-compartment model while the time course of hepatic glucose release was derived from the literature. Both noise-free and noisy experimental conditions were simulated. We showed that the degree of accuracy of Issekutz's approach is very good and better than the one associated with the hot-ginf method. On the other hand, the major problem with Issekutz's approach is the sensitivity of the volume estimate tot he measurement noise, which may limit its applicability in practice. In conclusion, we elucidated the theoretical grounds of Issekutz's approach and assessed its performance during nonsteady state in a realistic scenario using computer simulation.

KW - Glucose kinetics

KW - hepatic glucose release

KW - Mathematical model

KW - Nonsteady state

KW - Simulation

KW - Tracer kinetics

UR - http://www.scopus.com/inward/record.url?scp=0028215857&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028215857&partnerID=8YFLogxK

U2 - 10.1016/0169-2607(94)90058-2

DO - 10.1016/0169-2607(94)90058-2

M3 - Article

VL - 41

SP - 243

EP - 267

JO - Computer Methods and Programs in Biomedicine

JF - Computer Methods and Programs in Biomedicine

SN - 0169-2607

IS - 3-4

ER -