Surgical considerations and challenges for bilateral continuous-flow durable device implantation

Simon Maltais, Sara Womack, Mary E. Davis, Matthew R. Danter, Sudhir S. Kushwaha, John M. Stulak, Nicholas Haglund

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

The concept of biventricular support with durable centrifugal pumps is evolving, and the surgical strategy and best practice guidelines for implantation of right-sided devices are still unknown. We present optimal strategy for bilateral HeartWare continuous-flow ventricular assist device (HVAD) implantation in a series of four patients. Patients were implanted with the HVAD pumps simultaneously or sequentially. This report offers a perspective on surgical considerations such as right ventricular positioning, implications related to potential risks of obstruction from the tricuspid apparatus, the role if any of downsizing the outflow anastomosis, and considerations for speed adjustments. In this series, one patient died on support and three patients experienced pump thrombosis requiring device revision. All other patients survived until orthotopic heart transplantation, although one of these patients died from perioperative complications, 2 days posttransplantation. Surgical management of patients with medically refractory biventricular heart failure remains challenging and associated with a high incidence of pump thrombosis. Best practice guidelines from experts' consensus are still needed to address this challenging population.

Original languageEnglish (US)
Pages (from-to)e18-e21
JournalASAIO Journal
Volume62
Issue number2
DOIs
StatePublished - Mar 23 2016

Fingerprint

Pumps
Equipment and Supplies
Practice Guidelines
Centrifugal pumps
Heart-Assist Devices
Refractory materials
Thrombosis
Heart Transplantation
Heart Failure
Incidence
Population

Keywords

  • biventricular heart failure
  • bridge to transplant
  • mechanical circulatory support
  • ventricular assist

ASJC Scopus subject areas

  • Bioengineering
  • Biophysics
  • Medicine(all)
  • Biomaterials
  • Biomedical Engineering

Cite this

Maltais, S., Womack, S., Davis, M. E., Danter, M. R., Kushwaha, S. S., Stulak, J. M., & Haglund, N. (2016). Surgical considerations and challenges for bilateral continuous-flow durable device implantation. ASAIO Journal, 62(2), e18-e21. https://doi.org/10.1097/MAT.0000000000000297

Surgical considerations and challenges for bilateral continuous-flow durable device implantation. / Maltais, Simon; Womack, Sara; Davis, Mary E.; Danter, Matthew R.; Kushwaha, Sudhir S.; Stulak, John M.; Haglund, Nicholas.

In: ASAIO Journal, Vol. 62, No. 2, 23.03.2016, p. e18-e21.

Research output: Contribution to journalArticle

Maltais, S, Womack, S, Davis, ME, Danter, MR, Kushwaha, SS, Stulak, JM & Haglund, N 2016, 'Surgical considerations and challenges for bilateral continuous-flow durable device implantation', ASAIO Journal, vol. 62, no. 2, pp. e18-e21. https://doi.org/10.1097/MAT.0000000000000297
Maltais, Simon ; Womack, Sara ; Davis, Mary E. ; Danter, Matthew R. ; Kushwaha, Sudhir S. ; Stulak, John M. ; Haglund, Nicholas. / Surgical considerations and challenges for bilateral continuous-flow durable device implantation. In: ASAIO Journal. 2016 ; Vol. 62, No. 2. pp. e18-e21.
@article{d0c142d0887e49c9a84531c9103b185e,
title = "Surgical considerations and challenges for bilateral continuous-flow durable device implantation",
abstract = "The concept of biventricular support with durable centrifugal pumps is evolving, and the surgical strategy and best practice guidelines for implantation of right-sided devices are still unknown. We present optimal strategy for bilateral HeartWare continuous-flow ventricular assist device (HVAD) implantation in a series of four patients. Patients were implanted with the HVAD pumps simultaneously or sequentially. This report offers a perspective on surgical considerations such as right ventricular positioning, implications related to potential risks of obstruction from the tricuspid apparatus, the role if any of downsizing the outflow anastomosis, and considerations for speed adjustments. In this series, one patient died on support and three patients experienced pump thrombosis requiring device revision. All other patients survived until orthotopic heart transplantation, although one of these patients died from perioperative complications, 2 days posttransplantation. Surgical management of patients with medically refractory biventricular heart failure remains challenging and associated with a high incidence of pump thrombosis. Best practice guidelines from experts' consensus are still needed to address this challenging population.",
keywords = "biventricular heart failure, bridge to transplant, mechanical circulatory support, ventricular assist",
author = "Simon Maltais and Sara Womack and Davis, {Mary E.} and Danter, {Matthew R.} and Kushwaha, {Sudhir S.} and Stulak, {John M.} and Nicholas Haglund",
year = "2016",
month = "3",
day = "23",
doi = "10.1097/MAT.0000000000000297",
language = "English (US)",
volume = "62",
pages = "e18--e21",
journal = "ASAIO Journal",
issn = "0162-1432",
publisher = "Lippincott Williams and Wilkins",
number = "2",

}

TY - JOUR

T1 - Surgical considerations and challenges for bilateral continuous-flow durable device implantation

AU - Maltais, Simon

AU - Womack, Sara

AU - Davis, Mary E.

AU - Danter, Matthew R.

AU - Kushwaha, Sudhir S.

AU - Stulak, John M.

AU - Haglund, Nicholas

PY - 2016/3/23

Y1 - 2016/3/23

N2 - The concept of biventricular support with durable centrifugal pumps is evolving, and the surgical strategy and best practice guidelines for implantation of right-sided devices are still unknown. We present optimal strategy for bilateral HeartWare continuous-flow ventricular assist device (HVAD) implantation in a series of four patients. Patients were implanted with the HVAD pumps simultaneously or sequentially. This report offers a perspective on surgical considerations such as right ventricular positioning, implications related to potential risks of obstruction from the tricuspid apparatus, the role if any of downsizing the outflow anastomosis, and considerations for speed adjustments. In this series, one patient died on support and three patients experienced pump thrombosis requiring device revision. All other patients survived until orthotopic heart transplantation, although one of these patients died from perioperative complications, 2 days posttransplantation. Surgical management of patients with medically refractory biventricular heart failure remains challenging and associated with a high incidence of pump thrombosis. Best practice guidelines from experts' consensus are still needed to address this challenging population.

AB - The concept of biventricular support with durable centrifugal pumps is evolving, and the surgical strategy and best practice guidelines for implantation of right-sided devices are still unknown. We present optimal strategy for bilateral HeartWare continuous-flow ventricular assist device (HVAD) implantation in a series of four patients. Patients were implanted with the HVAD pumps simultaneously or sequentially. This report offers a perspective on surgical considerations such as right ventricular positioning, implications related to potential risks of obstruction from the tricuspid apparatus, the role if any of downsizing the outflow anastomosis, and considerations for speed adjustments. In this series, one patient died on support and three patients experienced pump thrombosis requiring device revision. All other patients survived until orthotopic heart transplantation, although one of these patients died from perioperative complications, 2 days posttransplantation. Surgical management of patients with medically refractory biventricular heart failure remains challenging and associated with a high incidence of pump thrombosis. Best practice guidelines from experts' consensus are still needed to address this challenging population.

KW - biventricular heart failure

KW - bridge to transplant

KW - mechanical circulatory support

KW - ventricular assist

UR - http://www.scopus.com/inward/record.url?scp=84961199626&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84961199626&partnerID=8YFLogxK

U2 - 10.1097/MAT.0000000000000297

DO - 10.1097/MAT.0000000000000297

M3 - Article

C2 - 26479465

AN - SCOPUS:84961199626

VL - 62

SP - e18-e21

JO - ASAIO Journal

JF - ASAIO Journal

SN - 0162-1432

IS - 2

ER -