Surface Roughness of Titanium Orthopedic Implants Alters the Biological Phenotype of Human Mesenchymal Stromal Cells

Eric A. Lewallen, William H. Trousdale, Roman Thaler, Jie J. Yao, Wei Xu, Janet M. Denbeigh, Asha Nair, Jean Pierre Kocher, Amel Dudakovic, Daniel J. Berry, Robert C. Cohen, Matthew P. Abdel, David G. Lewallen, Andre J. Van Wijnen

Research output: Contribution to journalArticlepeer-review

Abstract

Metal orthopedic implants are largely biocompatible and generally achieve long-term structural fixation. However, some orthopedic implants may loosen over time even in the absence of infection. In vivo fixation failure is multifactorial, but the fundamental biological defect is cellular dysfunction at the host-implant interface. Strategies to reduce the risk of short- and long-term loosening include surface modifications, implant metal alloy type, and adjuvant substances such as polymethylmethacrylate cement. Surface modifications (e.g., increased surface rugosity) can increase osseointegration and biological ingrowth of orthopedic implants. However, the localized responses of cells to implant surface modifications need to be better characterized. As an in vitro model for investigating cellular responses to metallic orthopedic implants, we cultured mesenchymal stromal/stem cells on clinical-grade titanium disks (Ti6Al4V) that differed in surface roughness as high (porous structured), medium (grit blasted), and low (bead blasted). Topological characterization of clinically relevant titanium (Ti) materials combined with differential mRNA expression analyses (RNA-seq and real-time quantitative polymerase chain reaction) revealed alterations to the biological phenotype of cells cultured on titanium structures that favor early extracellular matrix production and observable responses to oxidative stress and heavy metal stress. These results provide a descriptive model for the interpretation of cellular responses at the interface between native host tissues and three-dimensionally printed modular orthopedic implants, and will guide future studies aimed at increasing the long-term retention of such materials after total joint arthroplasty. Using an in vitro model of implant-to-cell interactions by culturing mesenchymal stromal cells (MSCs) on clinically relevant titanium materials of varying topological roughness, we identified mRNA expression patterns consistent with early extracellular matrix (ECM) production and responses to oxidative/heavy metal stress. Implants with high surface roughness may delay the differentiation and ECM formation of MSCs and alter the expression of genes sensitive to reactive oxygen species and protein kinases. In combination with ongoing animal studies, these results will guide future studies aimed at increasing the long-term retention of widely used titanium materials after total joint arthroplasty.

Original languageEnglish (US)
Pages (from-to)1503-1516
Number of pages14
JournalTissue Engineering - Part A
Volume27
Issue number23-24
DOIs
StatePublished - Dec 2021

Keywords

  • cell adhesion
  • microenvironment
  • stem cell behavior
  • surface modification
  • titanium
  • titanium alloy (TiAl6V4)

ASJC Scopus subject areas

  • Bioengineering
  • Biochemistry
  • Biomedical Engineering
  • Biomaterials

Fingerprint

Dive into the research topics of 'Surface Roughness of Titanium Orthopedic Implants Alters the Biological Phenotype of Human Mesenchymal Stromal Cells'. Together they form a unique fingerprint.

Cite this