T1 - Spiral nitinol biliary stents in a porcine model
T2 - Evaluation of the potential for use in benign strictures
AU - Van Os, E. C.
AU - Petersen, B. T.
AU - Batts, K. P.
PY - 1999/5/5
Y1 - 1999/5/5
N2 - Background and Study Aims: Self-expanding spiral nitinol stents are potentially removable and may be useful in the treatment of benign strictures. We evaluated the histologic response to stent placement and technical aspects of their placement and removal in a porcine model. Methods: Nine animals were studied. Stents were placed above the papilla in six surviving animals. After intervals of one, two or three months cholangiography and attempted stent removal was performed. Four animals were then sacrificed acutely with their stent in place, and two were sacrificed after a one-month healing interval. The results of placement, follow-up cholangiography and histology are reported. Results: Cholangiography and stent placement succeeded in 26 of 27 and 11 of 16 attempts, respectively. Three placement failures were attributed to stent/duct size disparity or a faulty release mechanism, resulting in stent kinking and/or duct twisting. Among the successfully deployed stents, two animals developed strictures where stents traversed bifurcations and one exhibited partial luminal compromise by tissue entrapment between coils. Fluoroscopically guided removal was successful in two of five stents positioned above the papilla. Histology was non-specific but minimally changed in those given a one-month healing interval after removal. Others exhibited moderate inflammation, fibrosis and an intramural abscess at sites of induced stricture. Conclusions: Spiral metal stents for the treatment of benign strictures remain experimental. Care must be taken to deploy them in bile ducts of adequate diameter and endoscopic removal is not yet demonstrably reliable and safe.
AB - Background and Study Aims: Self-expanding spiral nitinol stents are potentially removable and may be useful in the treatment of benign strictures. We evaluated the histologic response to stent placement and technical aspects of their placement and removal in a porcine model. Methods: Nine animals were studied. Stents were placed above the papilla in six surviving animals. After intervals of one, two or three months cholangiography and attempted stent removal was performed. Four animals were then sacrificed acutely with their stent in place, and two were sacrificed after a one-month healing interval. The results of placement, follow-up cholangiography and histology are reported. Results: Cholangiography and stent placement succeeded in 26 of 27 and 11 of 16 attempts, respectively. Three placement failures were attributed to stent/duct size disparity or a faulty release mechanism, resulting in stent kinking and/or duct twisting. Among the successfully deployed stents, two animals developed strictures where stents traversed bifurcations and one exhibited partial luminal compromise by tissue entrapment between coils. Fluoroscopically guided removal was successful in two of five stents positioned above the papilla. Histology was non-specific but minimally changed in those given a one-month healing interval after removal. Others exhibited moderate inflammation, fibrosis and an intramural abscess at sites of induced stricture. Conclusions: Spiral metal stents for the treatment of benign strictures remain experimental. Care must be taken to deploy them in bile ducts of adequate diameter and endoscopic removal is not yet demonstrably reliable and safe.
UR - http://www.scopus.com/inward/record.url?scp=0032935223&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0032935223&partnerID=8YFLogxK
U2 - 10.1055/s-1999-13678
DO - 10.1055/s-1999-13678
M3 - Article
C2 - 10344431
AN - SCOPUS:0032935223
SN - 0013-726X
VL - 31
SP - 253
EP - 259
JO - Endoscopy
JF - Endoscopy
IS - 3
ER -