Sonographically guided popliteus tendon sheath injection techniques and accuracy

Jay Smith, Jonathan T. Finnoff, Borja Santaella-Sante, Troy Henning, Bruce A Levy, Jim K. Lai

Research output: Contribution to journalArticle

19 Citations (Scopus)

Abstract

Objective. The purpose of this investigation was to describe two sonographically guided popliteus tendon sheath injection techniques and determine their accuracy in a cadaveric model. Methods. A single experienced operator completed 24 sonographically guided popliteus tendon sheath injections, 12 using a longitudinal approach and 12 using a transverse approach relative to the tendon. The injection order was randomized, and all injections were completed with diluted colored latex. Coinvestigators blinded to the injection technique dissected each specimen and graded the colored latex location as accurate (in the sheath), accurate with overflow (within the sheath but also in other regions), or inaccurate (no latex in the sheath). Results. All 12 sonographically guided popliteus sheath injections using the longitudinal approach placed latex into the sheath. Eight of these injections (67%) also resulted in overflow into the knee joint. Ten of 12 transverse approach injections placed latex into the sheath (83%), with 7 of these (70%) also producing overflow into the knee joint. Two of 12 transverse injections (17%) placed latex only into the knee joint and were therefore inaccurate. Conclusions. Sonographic guidance can be used to inject the popliteus tendon sheath with a high degree of accuracy. Although the longitudinal approach is potentially more accurate, both approaches may result in injectate overflow into the knee joint, likely through the popliteus hiatus.

Original languageEnglish (US)
Pages (from-to)775-782
Number of pages8
JournalJournal of Ultrasound in Medicine
Volume29
Issue number5
StatePublished - May 1 2010

Fingerprint

Tendons
Latex
Injections
Knee Joint

Keywords

  • Injection
  • Knee
  • Popliteus
  • Sonography

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Radiological and Ultrasound Technology
  • Medicine(all)

Cite this

Smith, J., Finnoff, J. T., Santaella-Sante, B., Henning, T., Levy, B. A., & Lai, J. K. (2010). Sonographically guided popliteus tendon sheath injection techniques and accuracy. Journal of Ultrasound in Medicine, 29(5), 775-782.

Sonographically guided popliteus tendon sheath injection techniques and accuracy. / Smith, Jay; Finnoff, Jonathan T.; Santaella-Sante, Borja; Henning, Troy; Levy, Bruce A; Lai, Jim K.

In: Journal of Ultrasound in Medicine, Vol. 29, No. 5, 01.05.2010, p. 775-782.

Research output: Contribution to journalArticle

Smith, J, Finnoff, JT, Santaella-Sante, B, Henning, T, Levy, BA & Lai, JK 2010, 'Sonographically guided popliteus tendon sheath injection techniques and accuracy', Journal of Ultrasound in Medicine, vol. 29, no. 5, pp. 775-782.
Smith, Jay ; Finnoff, Jonathan T. ; Santaella-Sante, Borja ; Henning, Troy ; Levy, Bruce A ; Lai, Jim K. / Sonographically guided popliteus tendon sheath injection techniques and accuracy. In: Journal of Ultrasound in Medicine. 2010 ; Vol. 29, No. 5. pp. 775-782.
@article{3802283418694e43a9efa9e81f0e9255,
title = "Sonographically guided popliteus tendon sheath injection techniques and accuracy",
abstract = "Objective. The purpose of this investigation was to describe two sonographically guided popliteus tendon sheath injection techniques and determine their accuracy in a cadaveric model. Methods. A single experienced operator completed 24 sonographically guided popliteus tendon sheath injections, 12 using a longitudinal approach and 12 using a transverse approach relative to the tendon. The injection order was randomized, and all injections were completed with diluted colored latex. Coinvestigators blinded to the injection technique dissected each specimen and graded the colored latex location as accurate (in the sheath), accurate with overflow (within the sheath but also in other regions), or inaccurate (no latex in the sheath). Results. All 12 sonographically guided popliteus sheath injections using the longitudinal approach placed latex into the sheath. Eight of these injections (67{\%}) also resulted in overflow into the knee joint. Ten of 12 transverse approach injections placed latex into the sheath (83{\%}), with 7 of these (70{\%}) also producing overflow into the knee joint. Two of 12 transverse injections (17{\%}) placed latex only into the knee joint and were therefore inaccurate. Conclusions. Sonographic guidance can be used to inject the popliteus tendon sheath with a high degree of accuracy. Although the longitudinal approach is potentially more accurate, both approaches may result in injectate overflow into the knee joint, likely through the popliteus hiatus.",
keywords = "Injection, Knee, Popliteus, Sonography",
author = "Jay Smith and Finnoff, {Jonathan T.} and Borja Santaella-Sante and Troy Henning and Levy, {Bruce A} and Lai, {Jim K.}",
year = "2010",
month = "5",
day = "1",
language = "English (US)",
volume = "29",
pages = "775--782",
journal = "Journal of Ultrasound in Medicine",
issn = "0278-4297",
publisher = "American Institute of Ultrasound in Medicine",
number = "5",

}

TY - JOUR

T1 - Sonographically guided popliteus tendon sheath injection techniques and accuracy

AU - Smith, Jay

AU - Finnoff, Jonathan T.

AU - Santaella-Sante, Borja

AU - Henning, Troy

AU - Levy, Bruce A

AU - Lai, Jim K.

PY - 2010/5/1

Y1 - 2010/5/1

N2 - Objective. The purpose of this investigation was to describe two sonographically guided popliteus tendon sheath injection techniques and determine their accuracy in a cadaveric model. Methods. A single experienced operator completed 24 sonographically guided popliteus tendon sheath injections, 12 using a longitudinal approach and 12 using a transverse approach relative to the tendon. The injection order was randomized, and all injections were completed with diluted colored latex. Coinvestigators blinded to the injection technique dissected each specimen and graded the colored latex location as accurate (in the sheath), accurate with overflow (within the sheath but also in other regions), or inaccurate (no latex in the sheath). Results. All 12 sonographically guided popliteus sheath injections using the longitudinal approach placed latex into the sheath. Eight of these injections (67%) also resulted in overflow into the knee joint. Ten of 12 transverse approach injections placed latex into the sheath (83%), with 7 of these (70%) also producing overflow into the knee joint. Two of 12 transverse injections (17%) placed latex only into the knee joint and were therefore inaccurate. Conclusions. Sonographic guidance can be used to inject the popliteus tendon sheath with a high degree of accuracy. Although the longitudinal approach is potentially more accurate, both approaches may result in injectate overflow into the knee joint, likely through the popliteus hiatus.

AB - Objective. The purpose of this investigation was to describe two sonographically guided popliteus tendon sheath injection techniques and determine their accuracy in a cadaveric model. Methods. A single experienced operator completed 24 sonographically guided popliteus tendon sheath injections, 12 using a longitudinal approach and 12 using a transverse approach relative to the tendon. The injection order was randomized, and all injections were completed with diluted colored latex. Coinvestigators blinded to the injection technique dissected each specimen and graded the colored latex location as accurate (in the sheath), accurate with overflow (within the sheath but also in other regions), or inaccurate (no latex in the sheath). Results. All 12 sonographically guided popliteus sheath injections using the longitudinal approach placed latex into the sheath. Eight of these injections (67%) also resulted in overflow into the knee joint. Ten of 12 transverse approach injections placed latex into the sheath (83%), with 7 of these (70%) also producing overflow into the knee joint. Two of 12 transverse injections (17%) placed latex only into the knee joint and were therefore inaccurate. Conclusions. Sonographic guidance can be used to inject the popliteus tendon sheath with a high degree of accuracy. Although the longitudinal approach is potentially more accurate, both approaches may result in injectate overflow into the knee joint, likely through the popliteus hiatus.

KW - Injection

KW - Knee

KW - Popliteus

KW - Sonography

UR - http://www.scopus.com/inward/record.url?scp=77951964858&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77951964858&partnerID=8YFLogxK

M3 - Article

VL - 29

SP - 775

EP - 782

JO - Journal of Ultrasound in Medicine

JF - Journal of Ultrasound in Medicine

SN - 0278-4297

IS - 5

ER -