Sonication of explanted prosthetic components in bags for diagnosis of prosthetic joint infection is associated with risk of contamination

Andrej Trampuz, Kerryl E. Piper, Arlen D. Hanssen, Douglas R. Osmon, Franklin R. Cockerill, James M. Steckelberg, Robin Patel

Research output: Contribution to journalArticle

142 Scopus citations

Abstract

Explanted orthopedic implants from 54 patients with aseptic failure and 24 patients with prosthetic knee or hip infection were sonicated in polyethylene bags. The sensitivities of periprosthetic tissue and sonicate fluid cultures for the diagnosis of prosthetic joint infection were 54% and 75%, whereas the specificities were 98% and 87%, respectively. Sonication in bags improved bacterial recovery from the surface of orthopedic implants; however, it lacked specificity, due to bag leakage.

Original languageEnglish (US)
Pages (from-to)628-631
Number of pages4
JournalJournal of clinical microbiology
Volume44
Issue number2
DOIs
StatePublished - Feb 2006

ASJC Scopus subject areas

  • Microbiology (medical)

Fingerprint Dive into the research topics of 'Sonication of explanted prosthetic components in bags for diagnosis of prosthetic joint infection is associated with risk of contamination'. Together they form a unique fingerprint.