T1 - Sonication improves microbiologic diagnosis of periprosthetic elbow infection
AU - Flurin, Laure
AU - Greenwood-Quaintance, Kerryl E.
AU - Esper, Ronda N.
AU - Sanchez-Sotelo, Joaquin
AU - Patel, Robin
N1 - Funding Information:
Robin Patel reports grants from Merck, ContraFect, TenNor Therapeutics Limited and Shionogi. She is a consultant to Curetis, Specific Technologies, Next Gen Diagnostics, PathoQuest, Selux Diagnostics, 1928 Diagnostics, PhAST, and Qvella; monies are paid to Mayo Clinic. She is also a consultant to Netflix. In addition, she has a patent on Bordetella pertussis/parapertussis polymerase chain reaction issued, a patent on a device/method for sonication with royalties paid by Samsung to Mayo Clinic, and a patent on an antibiofilm substance issued. She receives an editor’s stipend from the Infectious Diseases Society of America, and honoraria from the National Board of Medical Examiners, Up-to-Date, and the Infectious Diseases Board Review Course.
Funding Information:
The National Institute of Arthritis and Musculoskeletal and Skin Diseases of the National Institute of Health supported research funding for this article (RO1 AR056647).
Publisher Copyright:
© 2021 Journal of Shoulder and Elbow Surgery Board of Trustees
PY - 2021/8
Y1 - 2021/8
N2 - Background: Periprosthetic joint infection (PJI) is a relatively frequent and oftentimes devastating complication after total elbow arthroplasty (TEA). Its microbiologic diagnosis is usually based on periprosthetic tissue culture (hereafter referred to as tissue culture), but the sensitivity of tissue culture is variable. Although implant sonication culture has been shown to be superior to tissue culture for the diagnosis of hip and knee PJI, only a single small study (of fewer than 10 infected implants) has assessed sonication for PJI diagnosis after elbow arthroplasty. Methods: We retrospectively analyzed 112 sonicate fluid cultures from patients who underwent revision of a TEA at a single institution between 2007 and 2019, comparing results to those of tissue cultures. We excluded patients who had fewer than 2 tissues submitted for culture. Using the Infectious Diseases Society of America guidelines to define PJI, there were 49 infected and 63 non-infected cases. Median ages in the PJI and non-infected groups were 66 and 61 years, respectively. In the non-infected group, 65% were female vs. 63% in the PJI group. We reviewed clinical characteristics and calculated the sensitivity and specificity of tissue compared with sonicate fluid culture. In addition, we compared the sensitivity of tissue culture to the combination of tissue and sonicate fluid culture. Results: The most common pathogens were coagulase-negative Staphylococcus sp (49%), followed by Staphylococcus aureus (12%). Sensitivity of tissue culture was 63%, and sensitivity of sonicate fluid culture was 76% (P = .109). Specificity of tissue culture was 94% and specificity of sonicate fluid culture was 100%. Sensitivity of sonicate fluid culture in combination with tissue culture was 84% (P = .002 compared to tissue culture alone). Conclusion: In this study, we found that the combination of sonicate fluid and tissue culture had a greater sensitivity than tissue culture alone for microbiologic diagnosis of PJI after TEA.
AB - Background: Periprosthetic joint infection (PJI) is a relatively frequent and oftentimes devastating complication after total elbow arthroplasty (TEA). Its microbiologic diagnosis is usually based on periprosthetic tissue culture (hereafter referred to as tissue culture), but the sensitivity of tissue culture is variable. Although implant sonication culture has been shown to be superior to tissue culture for the diagnosis of hip and knee PJI, only a single small study (of fewer than 10 infected implants) has assessed sonication for PJI diagnosis after elbow arthroplasty. Methods: We retrospectively analyzed 112 sonicate fluid cultures from patients who underwent revision of a TEA at a single institution between 2007 and 2019, comparing results to those of tissue cultures. We excluded patients who had fewer than 2 tissues submitted for culture. Using the Infectious Diseases Society of America guidelines to define PJI, there were 49 infected and 63 non-infected cases. Median ages in the PJI and non-infected groups were 66 and 61 years, respectively. In the non-infected group, 65% were female vs. 63% in the PJI group. We reviewed clinical characteristics and calculated the sensitivity and specificity of tissue compared with sonicate fluid culture. In addition, we compared the sensitivity of tissue culture to the combination of tissue and sonicate fluid culture. Results: The most common pathogens were coagulase-negative Staphylococcus sp (49%), followed by Staphylococcus aureus (12%). Sensitivity of tissue culture was 63%, and sensitivity of sonicate fluid culture was 76% (P = .109). Specificity of tissue culture was 94% and specificity of sonicate fluid culture was 100%. Sensitivity of sonicate fluid culture in combination with tissue culture was 84% (P = .002 compared to tissue culture alone). Conclusion: In this study, we found that the combination of sonicate fluid and tissue culture had a greater sensitivity than tissue culture alone for microbiologic diagnosis of PJI after TEA.
KW - Diagnostic Study
KW - Level III
KW - Sonication
KW - diagnosis
KW - microbiology
KW - periprosthetic joint infection
KW - sensitivity
KW - total elbow arthroplasty
UR - http://www.scopus.com/inward/record.url?scp=85105066655&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85105066655&partnerID=8YFLogxK
U2 - 10.1016/j.jse.2021.01.023
DO - 10.1016/j.jse.2021.01.023
M3 - Article
C2 - 33609642
AN - SCOPUS:85105066655
VL - 30
SP - 1741
EP - 1749
JO - Journal of Shoulder and Elbow Surgery
JF - Journal of Shoulder and Elbow Surgery
SN - 1058-2746
IS - 8
ER -