Seizure source imaging by means of FINE spatio-temporal dipole localization and directed transfer function in partial epilepsy patients

Yunfeng Lu, Lin Yang, Gregory Alan Worrell, Bin He

Research output: Contribution to journalArticle

63 Citations (Scopus)

Abstract

Objective: To investigate the usage of a high-density EEG recording system and source imaging technique for localizing seizure activity in patients with medically intractable partial epilepsy. Methods: High-density, 76-channel scalp EEG signals were recorded in 10 patients with partial epilepsy. The patients underwent routine clinical pre-surgical evaluation and all had resective surgery with seizure free outcome. After applying a FINE (first principle vectors) spatio-temporal source localization and DTF (directed transfer function) connectivity analysis approach, ictal sources were imaged. Effects of number of scalp EEG electrodes on the seizure localization were also assessed using 76, 64, 48, 32, and 21 electrodes, respectively. Results: Surgical resections were used to assess the source imaging results. Results from the 76-channel EEG in the 10 patients showed high correlation with the surgically resected brain regions. The localization of seizure onset zone from 76-channel EEG showed improved source detection accuracy compared to other EEG configurations with fewer electrodes. Conclusions: FINE together with DTF was able to localize seizure onset zones of partial epilepsy patients. High-density EEG recording can help achieve improved seizure source imaging. Significance: The present results suggest the promise of high-density EEG and electrical source imaging for noninvasively localizing seizure onset zones.

Original languageEnglish (US)
Pages (from-to)1275-1283
Number of pages9
JournalClinical Neurophysiology
Volume123
Issue number7
DOIs
StatePublished - Jul 2012

Fingerprint

Partial Epilepsy
Electroencephalography
Seizures
Electrodes
Scalp
Stroke
Brain

Keywords

  • Directed transfer function
  • EEG source imaging
  • Epilepsy
  • FINE
  • High-density EEG
  • Ictal activities

ASJC Scopus subject areas

  • Clinical Neurology
  • Neurology
  • Physiology (medical)
  • Sensory Systems

Cite this

Seizure source imaging by means of FINE spatio-temporal dipole localization and directed transfer function in partial epilepsy patients. / Lu, Yunfeng; Yang, Lin; Worrell, Gregory Alan; He, Bin.

In: Clinical Neurophysiology, Vol. 123, No. 7, 07.2012, p. 1275-1283.

Research output: Contribution to journalArticle

@article{6b35a08909e04f4483660141069e88b8,
title = "Seizure source imaging by means of FINE spatio-temporal dipole localization and directed transfer function in partial epilepsy patients",
abstract = "Objective: To investigate the usage of a high-density EEG recording system and source imaging technique for localizing seizure activity in patients with medically intractable partial epilepsy. Methods: High-density, 76-channel scalp EEG signals were recorded in 10 patients with partial epilepsy. The patients underwent routine clinical pre-surgical evaluation and all had resective surgery with seizure free outcome. After applying a FINE (first principle vectors) spatio-temporal source localization and DTF (directed transfer function) connectivity analysis approach, ictal sources were imaged. Effects of number of scalp EEG electrodes on the seizure localization were also assessed using 76, 64, 48, 32, and 21 electrodes, respectively. Results: Surgical resections were used to assess the source imaging results. Results from the 76-channel EEG in the 10 patients showed high correlation with the surgically resected brain regions. The localization of seizure onset zone from 76-channel EEG showed improved source detection accuracy compared to other EEG configurations with fewer electrodes. Conclusions: FINE together with DTF was able to localize seizure onset zones of partial epilepsy patients. High-density EEG recording can help achieve improved seizure source imaging. Significance: The present results suggest the promise of high-density EEG and electrical source imaging for noninvasively localizing seizure onset zones.",
keywords = "Directed transfer function, EEG source imaging, Epilepsy, FINE, High-density EEG, Ictal activities",
author = "Yunfeng Lu and Lin Yang and Worrell, {Gregory Alan} and Bin He",
year = "2012",
month = "7",
doi = "10.1016/j.clinph.2011.11.007",
language = "English (US)",
volume = "123",
pages = "1275--1283",
journal = "Clinical Neurophysiology",
issn = "1388-2457",
publisher = "Elsevier Ireland Ltd",
number = "7",

}

TY - JOUR

T1 - Seizure source imaging by means of FINE spatio-temporal dipole localization and directed transfer function in partial epilepsy patients

AU - Lu, Yunfeng

AU - Yang, Lin

AU - Worrell, Gregory Alan

AU - He, Bin

PY - 2012/7

Y1 - 2012/7

N2 - Objective: To investigate the usage of a high-density EEG recording system and source imaging technique for localizing seizure activity in patients with medically intractable partial epilepsy. Methods: High-density, 76-channel scalp EEG signals were recorded in 10 patients with partial epilepsy. The patients underwent routine clinical pre-surgical evaluation and all had resective surgery with seizure free outcome. After applying a FINE (first principle vectors) spatio-temporal source localization and DTF (directed transfer function) connectivity analysis approach, ictal sources were imaged. Effects of number of scalp EEG electrodes on the seizure localization were also assessed using 76, 64, 48, 32, and 21 electrodes, respectively. Results: Surgical resections were used to assess the source imaging results. Results from the 76-channel EEG in the 10 patients showed high correlation with the surgically resected brain regions. The localization of seizure onset zone from 76-channel EEG showed improved source detection accuracy compared to other EEG configurations with fewer electrodes. Conclusions: FINE together with DTF was able to localize seizure onset zones of partial epilepsy patients. High-density EEG recording can help achieve improved seizure source imaging. Significance: The present results suggest the promise of high-density EEG and electrical source imaging for noninvasively localizing seizure onset zones.

AB - Objective: To investigate the usage of a high-density EEG recording system and source imaging technique for localizing seizure activity in patients with medically intractable partial epilepsy. Methods: High-density, 76-channel scalp EEG signals were recorded in 10 patients with partial epilepsy. The patients underwent routine clinical pre-surgical evaluation and all had resective surgery with seizure free outcome. After applying a FINE (first principle vectors) spatio-temporal source localization and DTF (directed transfer function) connectivity analysis approach, ictal sources were imaged. Effects of number of scalp EEG electrodes on the seizure localization were also assessed using 76, 64, 48, 32, and 21 electrodes, respectively. Results: Surgical resections were used to assess the source imaging results. Results from the 76-channel EEG in the 10 patients showed high correlation with the surgically resected brain regions. The localization of seizure onset zone from 76-channel EEG showed improved source detection accuracy compared to other EEG configurations with fewer electrodes. Conclusions: FINE together with DTF was able to localize seizure onset zones of partial epilepsy patients. High-density EEG recording can help achieve improved seizure source imaging. Significance: The present results suggest the promise of high-density EEG and electrical source imaging for noninvasively localizing seizure onset zones.

KW - Directed transfer function

KW - EEG source imaging

KW - Epilepsy

KW - FINE

KW - High-density EEG

KW - Ictal activities

UR - http://www.scopus.com/inward/record.url?scp=84861675888&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84861675888&partnerID=8YFLogxK

U2 - 10.1016/j.clinph.2011.11.007

DO - 10.1016/j.clinph.2011.11.007

M3 - Article

C2 - 22172768

AN - SCOPUS:84861675888

VL - 123

SP - 1275

EP - 1283

JO - Clinical Neurophysiology

JF - Clinical Neurophysiology

SN - 1388-2457

IS - 7

ER -