Seed localization and TRUS-fluoroscopy fusion for intraoperative prostate brachytherapy dosimetry

Yi Su, Brian J. Davis, Keith M. Furutani, Michael G. Herman, Richard A. Robb

Research output: Contribution to journalArticle

30 Citations (Scopus)

Abstract

Objective: To develop and evaluate an integrated approach to intra-operative dosimetry for permanent prostate brachytherapy (PPB) by combining a fluoroscopy-based seed localization routine with a transrectal ultrasound (TRUS)-to-fluoroscopy fusion technique. Materials and Methods: Three-dimensional seed coordinates are reconstructed based on the two-dimensional seed locations identified from three fluoroscopic images acquired at different angles. A seed-based registration approach was examined in both simulation and phantom studies to register the seed locations identified from the fluoroscopic images to the TRUS images. Dose parameters were then evaluated and compared to CT-based dosimetry from a patient dataset. Results: Less than 0.2% error in the D90 value was observed using the TRUS-fluoroscopy image-fusion-based method relative to the CT-based post-implantation dosimetry. In the phantom study, an average distance of 3 mm was observed between the seeds identified from TRUS and the reconstructed seeds at registration. Isodose contours were displayed superimposed on the TRUS images. Conclusions: Promising results were observed in this preliminary study of a TRUS-fluoroscopy fusion-based brachytherapy dosimetry analysis method, suggesting that the method is highly sensitive and calculates clinically relevant dosimetry, including the prostate D90. Further validation of the method is required for eventual clinical application.

Original languageEnglish (US)
Pages (from-to)25-34
Number of pages10
JournalComputer Aided Surgery
Volume12
Issue number1
DOIs
StatePublished - Jan 2007

Fingerprint

Fluoroscopy
Brachytherapy
Dosimetry
Seed
Prostate
Seeds
Ultrasonics
Image fusion

Keywords

  • Dosimetry
  • Fluoroscopy
  • Image fusion
  • Prostate brachytherapy
  • TRUS

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Surgery
  • Medicine (miscellaneous)

Cite this

Seed localization and TRUS-fluoroscopy fusion for intraoperative prostate brachytherapy dosimetry. / Su, Yi; Davis, Brian J.; Furutani, Keith M.; Herman, Michael G.; Robb, Richard A.

In: Computer Aided Surgery, Vol. 12, No. 1, 01.2007, p. 25-34.

Research output: Contribution to journalArticle

Su, Yi ; Davis, Brian J. ; Furutani, Keith M. ; Herman, Michael G. ; Robb, Richard A. / Seed localization and TRUS-fluoroscopy fusion for intraoperative prostate brachytherapy dosimetry. In: Computer Aided Surgery. 2007 ; Vol. 12, No. 1. pp. 25-34.
@article{18411863f29a42cfb76a2bca35740fe8,
title = "Seed localization and TRUS-fluoroscopy fusion for intraoperative prostate brachytherapy dosimetry",
abstract = "Objective: To develop and evaluate an integrated approach to intra-operative dosimetry for permanent prostate brachytherapy (PPB) by combining a fluoroscopy-based seed localization routine with a transrectal ultrasound (TRUS)-to-fluoroscopy fusion technique. Materials and Methods: Three-dimensional seed coordinates are reconstructed based on the two-dimensional seed locations identified from three fluoroscopic images acquired at different angles. A seed-based registration approach was examined in both simulation and phantom studies to register the seed locations identified from the fluoroscopic images to the TRUS images. Dose parameters were then evaluated and compared to CT-based dosimetry from a patient dataset. Results: Less than 0.2{\%} error in the D90 value was observed using the TRUS-fluoroscopy image-fusion-based method relative to the CT-based post-implantation dosimetry. In the phantom study, an average distance of 3 mm was observed between the seeds identified from TRUS and the reconstructed seeds at registration. Isodose contours were displayed superimposed on the TRUS images. Conclusions: Promising results were observed in this preliminary study of a TRUS-fluoroscopy fusion-based brachytherapy dosimetry analysis method, suggesting that the method is highly sensitive and calculates clinically relevant dosimetry, including the prostate D90. Further validation of the method is required for eventual clinical application.",
keywords = "Dosimetry, Fluoroscopy, Image fusion, Prostate brachytherapy, TRUS",
author = "Yi Su and Davis, {Brian J.} and Furutani, {Keith M.} and Herman, {Michael G.} and Robb, {Richard A.}",
year = "2007",
month = "1",
doi = "10.1080/10929080601168239",
language = "English (US)",
volume = "12",
pages = "25--34",
journal = "Computer Assisted Surgery",
issn = "1092-9088",
publisher = "Taylor and Francis Ltd.",
number = "1",

}

TY - JOUR

T1 - Seed localization and TRUS-fluoroscopy fusion for intraoperative prostate brachytherapy dosimetry

AU - Su, Yi

AU - Davis, Brian J.

AU - Furutani, Keith M.

AU - Herman, Michael G.

AU - Robb, Richard A.

PY - 2007/1

Y1 - 2007/1

N2 - Objective: To develop and evaluate an integrated approach to intra-operative dosimetry for permanent prostate brachytherapy (PPB) by combining a fluoroscopy-based seed localization routine with a transrectal ultrasound (TRUS)-to-fluoroscopy fusion technique. Materials and Methods: Three-dimensional seed coordinates are reconstructed based on the two-dimensional seed locations identified from three fluoroscopic images acquired at different angles. A seed-based registration approach was examined in both simulation and phantom studies to register the seed locations identified from the fluoroscopic images to the TRUS images. Dose parameters were then evaluated and compared to CT-based dosimetry from a patient dataset. Results: Less than 0.2% error in the D90 value was observed using the TRUS-fluoroscopy image-fusion-based method relative to the CT-based post-implantation dosimetry. In the phantom study, an average distance of 3 mm was observed between the seeds identified from TRUS and the reconstructed seeds at registration. Isodose contours were displayed superimposed on the TRUS images. Conclusions: Promising results were observed in this preliminary study of a TRUS-fluoroscopy fusion-based brachytherapy dosimetry analysis method, suggesting that the method is highly sensitive and calculates clinically relevant dosimetry, including the prostate D90. Further validation of the method is required for eventual clinical application.

AB - Objective: To develop and evaluate an integrated approach to intra-operative dosimetry for permanent prostate brachytherapy (PPB) by combining a fluoroscopy-based seed localization routine with a transrectal ultrasound (TRUS)-to-fluoroscopy fusion technique. Materials and Methods: Three-dimensional seed coordinates are reconstructed based on the two-dimensional seed locations identified from three fluoroscopic images acquired at different angles. A seed-based registration approach was examined in both simulation and phantom studies to register the seed locations identified from the fluoroscopic images to the TRUS images. Dose parameters were then evaluated and compared to CT-based dosimetry from a patient dataset. Results: Less than 0.2% error in the D90 value was observed using the TRUS-fluoroscopy image-fusion-based method relative to the CT-based post-implantation dosimetry. In the phantom study, an average distance of 3 mm was observed between the seeds identified from TRUS and the reconstructed seeds at registration. Isodose contours were displayed superimposed on the TRUS images. Conclusions: Promising results were observed in this preliminary study of a TRUS-fluoroscopy fusion-based brachytherapy dosimetry analysis method, suggesting that the method is highly sensitive and calculates clinically relevant dosimetry, including the prostate D90. Further validation of the method is required for eventual clinical application.

KW - Dosimetry

KW - Fluoroscopy

KW - Image fusion

KW - Prostate brachytherapy

KW - TRUS

UR - http://www.scopus.com/inward/record.url?scp=33847120872&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33847120872&partnerID=8YFLogxK

U2 - 10.1080/10929080601168239

DO - 10.1080/10929080601168239

M3 - Article

C2 - 17364656

AN - SCOPUS:33847120872

VL - 12

SP - 25

EP - 34

JO - Computer Assisted Surgery

JF - Computer Assisted Surgery

SN - 1092-9088

IS - 1

ER -