Role of computed tomography voxel size in detection and discrimination of calcium and iron deposits in atherosclerotic human coronary artery specimens

Alexander C. Langheinrich, Marian Kampschulte, Christine Crömann, Regina Moritz, Wigbert S. Rau, Rainer M. Bohle, Erik L. Ritman

Research output: Contribution to journalArticle

18 Citations (Scopus)

Abstract

Objective:: This study evaluated the influence of voxel size on its ability to discriminate calcium from iron deposits in ex vivo coronary arteries. Methods:: Postmortem human coronary arteries underwent multislice computed tomographic scan at (600-μm) voxel size to provide an index of computed tomography (CT) image noise and synchrotron-based micro-CT at (4-μm) voxel size to provide data for generating a range of voxel sizes 4 to (600-μm) after grayscale noise was added to the projection images before reconstruction so as to mimic the effect of retaining the same radiation exposure involved in the multislice computed tomographic scan. Results:: At voxel sizes of (20-μm) or smaller, iron deposits could be identified based on CT grayscale value. Voxels of (100-μm) or larger cannot resolve nor distinguish iron deposits from calcifications by virtue of CT grayscale value. Conclusions:: Clinical CT scanners cannot be expected to discriminate iron deposits from calcifications by their CT value alone in the arterial wall.

Original languageEnglish (US)
Pages (from-to)517-522
Number of pages6
JournalJournal of Computer Assisted Tomography
Volume33
Issue number4
DOIs
StatePublished - Jul 2009

Fingerprint

Coronary Vessels
Iron
Tomography
Calcium
X-Ray Computed Tomography Scanners
Synchrotrons
Computer-Assisted Image Processing
Noise

Keywords

  • Atherosclerosis
  • Dual-source CT
  • Human coronary arteries
  • Imaging, micro-CT

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Role of computed tomography voxel size in detection and discrimination of calcium and iron deposits in atherosclerotic human coronary artery specimens. / Langheinrich, Alexander C.; Kampschulte, Marian; Crömann, Christine; Moritz, Regina; Rau, Wigbert S.; Bohle, Rainer M.; Ritman, Erik L.

In: Journal of Computer Assisted Tomography, Vol. 33, No. 4, 07.2009, p. 517-522.

Research output: Contribution to journalArticle

Langheinrich, Alexander C. ; Kampschulte, Marian ; Crömann, Christine ; Moritz, Regina ; Rau, Wigbert S. ; Bohle, Rainer M. ; Ritman, Erik L. / Role of computed tomography voxel size in detection and discrimination of calcium and iron deposits in atherosclerotic human coronary artery specimens. In: Journal of Computer Assisted Tomography. 2009 ; Vol. 33, No. 4. pp. 517-522.
@article{f285a2b0a4164c32a7c084bbec532c64,
title = "Role of computed tomography voxel size in detection and discrimination of calcium and iron deposits in atherosclerotic human coronary artery specimens",
abstract = "Objective:: This study evaluated the influence of voxel size on its ability to discriminate calcium from iron deposits in ex vivo coronary arteries. Methods:: Postmortem human coronary arteries underwent multislice computed tomographic scan at (600-μm) voxel size to provide an index of computed tomography (CT) image noise and synchrotron-based micro-CT at (4-μm) voxel size to provide data for generating a range of voxel sizes 4 to (600-μm) after grayscale noise was added to the projection images before reconstruction so as to mimic the effect of retaining the same radiation exposure involved in the multislice computed tomographic scan. Results:: At voxel sizes of (20-μm) or smaller, iron deposits could be identified based on CT grayscale value. Voxels of (100-μm) or larger cannot resolve nor distinguish iron deposits from calcifications by virtue of CT grayscale value. Conclusions:: Clinical CT scanners cannot be expected to discriminate iron deposits from calcifications by their CT value alone in the arterial wall.",
keywords = "Atherosclerosis, Dual-source CT, Human coronary arteries, Imaging, micro-CT",
author = "Langheinrich, {Alexander C.} and Marian Kampschulte and Christine Cr{\"o}mann and Regina Moritz and Rau, {Wigbert S.} and Bohle, {Rainer M.} and Ritman, {Erik L.}",
year = "2009",
month = "7",
doi = "10.1097/RCT.0b013e318194c0a2",
language = "English (US)",
volume = "33",
pages = "517--522",
journal = "Journal of Computer Assisted Tomography",
issn = "0363-8715",
publisher = "Lippincott Williams and Wilkins",
number = "4",

}

TY - JOUR

T1 - Role of computed tomography voxel size in detection and discrimination of calcium and iron deposits in atherosclerotic human coronary artery specimens

AU - Langheinrich, Alexander C.

AU - Kampschulte, Marian

AU - Crömann, Christine

AU - Moritz, Regina

AU - Rau, Wigbert S.

AU - Bohle, Rainer M.

AU - Ritman, Erik L.

PY - 2009/7

Y1 - 2009/7

N2 - Objective:: This study evaluated the influence of voxel size on its ability to discriminate calcium from iron deposits in ex vivo coronary arteries. Methods:: Postmortem human coronary arteries underwent multislice computed tomographic scan at (600-μm) voxel size to provide an index of computed tomography (CT) image noise and synchrotron-based micro-CT at (4-μm) voxel size to provide data for generating a range of voxel sizes 4 to (600-μm) after grayscale noise was added to the projection images before reconstruction so as to mimic the effect of retaining the same radiation exposure involved in the multislice computed tomographic scan. Results:: At voxel sizes of (20-μm) or smaller, iron deposits could be identified based on CT grayscale value. Voxels of (100-μm) or larger cannot resolve nor distinguish iron deposits from calcifications by virtue of CT grayscale value. Conclusions:: Clinical CT scanners cannot be expected to discriminate iron deposits from calcifications by their CT value alone in the arterial wall.

AB - Objective:: This study evaluated the influence of voxel size on its ability to discriminate calcium from iron deposits in ex vivo coronary arteries. Methods:: Postmortem human coronary arteries underwent multislice computed tomographic scan at (600-μm) voxel size to provide an index of computed tomography (CT) image noise and synchrotron-based micro-CT at (4-μm) voxel size to provide data for generating a range of voxel sizes 4 to (600-μm) after grayscale noise was added to the projection images before reconstruction so as to mimic the effect of retaining the same radiation exposure involved in the multislice computed tomographic scan. Results:: At voxel sizes of (20-μm) or smaller, iron deposits could be identified based on CT grayscale value. Voxels of (100-μm) or larger cannot resolve nor distinguish iron deposits from calcifications by virtue of CT grayscale value. Conclusions:: Clinical CT scanners cannot be expected to discriminate iron deposits from calcifications by their CT value alone in the arterial wall.

KW - Atherosclerosis

KW - Dual-source CT

KW - Human coronary arteries

KW - Imaging, micro-CT

UR - http://www.scopus.com/inward/record.url?scp=68949107632&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=68949107632&partnerID=8YFLogxK

U2 - 10.1097/RCT.0b013e318194c0a2

DO - 10.1097/RCT.0b013e318194c0a2

M3 - Article

C2 - 19638842

AN - SCOPUS:68949107632

VL - 33

SP - 517

EP - 522

JO - Journal of Computer Assisted Tomography

JF - Journal of Computer Assisted Tomography

SN - 0363-8715

IS - 4

ER -