Reliability of maximal voluntary isometric contraction testing in a multicenter study of patients with amyotrophic lateral sclerosis

Rebecca J. Hoagland, Michelle Mendoza, Carmel Armon, Richard J. Barohn, Wilson W. Bryan, Jessie C. Goodpasture, Robert G. Miller, Gareth J. Parry, Jack H. Petajan, Mark A Ross

Research output: Contribution to journalArticle

35 Citations (Scopus)

Abstract

Maximal voluntary isometric contraction (MVIC) is becoming widely used for monitoring disease progression in amyotrophic lateral sclerosis (ALS). We evaluated the variability of MVIC in a large multicenter (29 sites) drug trial in ALS. Intra- and interrater variability were assessed twice during the 19-month study. Intrarater reliability increased from the first to the second test, approaching the reliability reported for a single experienced clinical evaluator, but interrater reliability did not. Multiple clinical evaluators in a single site increased the variability of MVIC measurements. Rigorous quality assurance standards and monitoring of clinical evaluators should be incorporated into the design of multicenter studies using MVIC, since low variability is necessary to detect a modest treatment effect.

Original languageEnglish (US)
Pages (from-to)691-695
Number of pages5
JournalMuscle and Nerve
Volume20
Issue number6
DOIs
StatePublished - 1997
Externally publishedYes

Fingerprint

Isometric Contraction
Amyotrophic Lateral Sclerosis
Multicenter Studies
Disease Progression
Pharmaceutical Preparations
Therapeutics

Keywords

  • amyotrophic lateral sclerosis
  • clinical trials
  • maximum voluntary isometric contraction
  • reliability
  • variability

ASJC Scopus subject areas

  • Clinical Neurology
  • Neuroscience(all)

Cite this

Reliability of maximal voluntary isometric contraction testing in a multicenter study of patients with amyotrophic lateral sclerosis. / Hoagland, Rebecca J.; Mendoza, Michelle; Armon, Carmel; Barohn, Richard J.; Bryan, Wilson W.; Goodpasture, Jessie C.; Miller, Robert G.; Parry, Gareth J.; Petajan, Jack H.; Ross, Mark A.

In: Muscle and Nerve, Vol. 20, No. 6, 1997, p. 691-695.

Research output: Contribution to journalArticle

Hoagland, Rebecca J. ; Mendoza, Michelle ; Armon, Carmel ; Barohn, Richard J. ; Bryan, Wilson W. ; Goodpasture, Jessie C. ; Miller, Robert G. ; Parry, Gareth J. ; Petajan, Jack H. ; Ross, Mark A. / Reliability of maximal voluntary isometric contraction testing in a multicenter study of patients with amyotrophic lateral sclerosis. In: Muscle and Nerve. 1997 ; Vol. 20, No. 6. pp. 691-695.
@article{cc9d310ccf4b41e5a4a1028b81144790,
title = "Reliability of maximal voluntary isometric contraction testing in a multicenter study of patients with amyotrophic lateral sclerosis",
abstract = "Maximal voluntary isometric contraction (MVIC) is becoming widely used for monitoring disease progression in amyotrophic lateral sclerosis (ALS). We evaluated the variability of MVIC in a large multicenter (29 sites) drug trial in ALS. Intra- and interrater variability were assessed twice during the 19-month study. Intrarater reliability increased from the first to the second test, approaching the reliability reported for a single experienced clinical evaluator, but interrater reliability did not. Multiple clinical evaluators in a single site increased the variability of MVIC measurements. Rigorous quality assurance standards and monitoring of clinical evaluators should be incorporated into the design of multicenter studies using MVIC, since low variability is necessary to detect a modest treatment effect.",
keywords = "amyotrophic lateral sclerosis, clinical trials, maximum voluntary isometric contraction, reliability, variability",
author = "Hoagland, {Rebecca J.} and Michelle Mendoza and Carmel Armon and Barohn, {Richard J.} and Bryan, {Wilson W.} and Goodpasture, {Jessie C.} and Miller, {Robert G.} and Parry, {Gareth J.} and Petajan, {Jack H.} and Ross, {Mark A}",
year = "1997",
doi = "10.1002/(SICI)1097-4598(199706)20:6<691::AID-MUS5>3.0.CO;2-3",
language = "English (US)",
volume = "20",
pages = "691--695",
journal = "Muscle and Nerve",
issn = "0148-639X",
publisher = "John Wiley and Sons Inc.",
number = "6",

}

TY - JOUR

T1 - Reliability of maximal voluntary isometric contraction testing in a multicenter study of patients with amyotrophic lateral sclerosis

AU - Hoagland, Rebecca J.

AU - Mendoza, Michelle

AU - Armon, Carmel

AU - Barohn, Richard J.

AU - Bryan, Wilson W.

AU - Goodpasture, Jessie C.

AU - Miller, Robert G.

AU - Parry, Gareth J.

AU - Petajan, Jack H.

AU - Ross, Mark A

PY - 1997

Y1 - 1997

N2 - Maximal voluntary isometric contraction (MVIC) is becoming widely used for monitoring disease progression in amyotrophic lateral sclerosis (ALS). We evaluated the variability of MVIC in a large multicenter (29 sites) drug trial in ALS. Intra- and interrater variability were assessed twice during the 19-month study. Intrarater reliability increased from the first to the second test, approaching the reliability reported for a single experienced clinical evaluator, but interrater reliability did not. Multiple clinical evaluators in a single site increased the variability of MVIC measurements. Rigorous quality assurance standards and monitoring of clinical evaluators should be incorporated into the design of multicenter studies using MVIC, since low variability is necessary to detect a modest treatment effect.

AB - Maximal voluntary isometric contraction (MVIC) is becoming widely used for monitoring disease progression in amyotrophic lateral sclerosis (ALS). We evaluated the variability of MVIC in a large multicenter (29 sites) drug trial in ALS. Intra- and interrater variability were assessed twice during the 19-month study. Intrarater reliability increased from the first to the second test, approaching the reliability reported for a single experienced clinical evaluator, but interrater reliability did not. Multiple clinical evaluators in a single site increased the variability of MVIC measurements. Rigorous quality assurance standards and monitoring of clinical evaluators should be incorporated into the design of multicenter studies using MVIC, since low variability is necessary to detect a modest treatment effect.

KW - amyotrophic lateral sclerosis

KW - clinical trials

KW - maximum voluntary isometric contraction

KW - reliability

KW - variability

UR - http://www.scopus.com/inward/record.url?scp=0031005199&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031005199&partnerID=8YFLogxK

U2 - 10.1002/(SICI)1097-4598(199706)20:6<691::AID-MUS5>3.0.CO;2-3

DO - 10.1002/(SICI)1097-4598(199706)20:6<691::AID-MUS5>3.0.CO;2-3

M3 - Article

C2 - 9149075

AN - SCOPUS:0031005199

VL - 20

SP - 691

EP - 695

JO - Muscle and Nerve

JF - Muscle and Nerve

SN - 0148-639X

IS - 6

ER -