Reliability of a novel ultrasound system for gray-scale analysis of muscle

Travis G. O'brien, Meaghan L. Cazares Gonzalez, Partha S. Ghosh, Jayawant Mandrekar, Andrea Boon

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

Introduction: Ultrasound is increasingly used as an adjunct in the diagnosis of neuromuscular disease by measuring muscle thickness and echointensity (EI). Reproducibility is limited because of variations in scanning technique and proprietary algorithms that alter EI values. Methods: We developed a standardized scanning protocol and a portable machine without any postimaging processing. Ten subjects underwent scanning of 6 muscles by 3 sonographers on 2 separate days. One of the sonographers repeated the protocol with 4 different machine/transducer combinations. Gray-scale values were measured from each image with the use of a region of interest (ROI) box. Results: Combined intraclass correlation coefficients were 0.92 (intra-rater), 0.88 (inter-rater), and 0.96 (inter-system). The biceps had the highest variability (coefficient of variance [COV] 12.7%), and the medial gastrocnemius had the lowest variability (COV 7.4%). Conclusions: We demonstrate excellent reliability of a reproducible ultrasound system for gray-scale analysis of muscle that has potential applicability as a screening tool for neuromuscular disease.

Original languageEnglish (US)
JournalMuscle and Nerve
DOIs
StateAccepted/In press - 2017

Fingerprint

Neuromuscular Diseases
Muscles
Transducers

Keywords

  • Gray-scale analysis
  • Muscle ultrasound
  • Neuromuscular disease
  • Pediatric
  • Reliability
  • Screening tool

ASJC Scopus subject areas

  • Physiology
  • Clinical Neurology
  • Cellular and Molecular Neuroscience
  • Physiology (medical)

Cite this

Reliability of a novel ultrasound system for gray-scale analysis of muscle. / O'brien, Travis G.; Cazares Gonzalez, Meaghan L.; Ghosh, Partha S.; Mandrekar, Jayawant; Boon, Andrea.

In: Muscle and Nerve, 2017.

Research output: Contribution to journalArticle

O'brien, Travis G. ; Cazares Gonzalez, Meaghan L. ; Ghosh, Partha S. ; Mandrekar, Jayawant ; Boon, Andrea. / Reliability of a novel ultrasound system for gray-scale analysis of muscle. In: Muscle and Nerve. 2017.
@article{14afc38db7684473a3469112479db2ec,
title = "Reliability of a novel ultrasound system for gray-scale analysis of muscle",
abstract = "Introduction: Ultrasound is increasingly used as an adjunct in the diagnosis of neuromuscular disease by measuring muscle thickness and echointensity (EI). Reproducibility is limited because of variations in scanning technique and proprietary algorithms that alter EI values. Methods: We developed a standardized scanning protocol and a portable machine without any postimaging processing. Ten subjects underwent scanning of 6 muscles by 3 sonographers on 2 separate days. One of the sonographers repeated the protocol with 4 different machine/transducer combinations. Gray-scale values were measured from each image with the use of a region of interest (ROI) box. Results: Combined intraclass correlation coefficients were 0.92 (intra-rater), 0.88 (inter-rater), and 0.96 (inter-system). The biceps had the highest variability (coefficient of variance [COV] 12.7{\%}), and the medial gastrocnemius had the lowest variability (COV 7.4{\%}). Conclusions: We demonstrate excellent reliability of a reproducible ultrasound system for gray-scale analysis of muscle that has potential applicability as a screening tool for neuromuscular disease.",
keywords = "Gray-scale analysis, Muscle ultrasound, Neuromuscular disease, Pediatric, Reliability, Screening tool",
author = "O'brien, {Travis G.} and {Cazares Gonzalez}, {Meaghan L.} and Ghosh, {Partha S.} and Jayawant Mandrekar and Andrea Boon",
year = "2017",
doi = "10.1002/mus.25513",
language = "English (US)",
journal = "Muscle and Nerve",
issn = "0148-639X",
publisher = "John Wiley and Sons Inc.",

}

TY - JOUR

T1 - Reliability of a novel ultrasound system for gray-scale analysis of muscle

AU - O'brien, Travis G.

AU - Cazares Gonzalez, Meaghan L.

AU - Ghosh, Partha S.

AU - Mandrekar, Jayawant

AU - Boon, Andrea

PY - 2017

Y1 - 2017

N2 - Introduction: Ultrasound is increasingly used as an adjunct in the diagnosis of neuromuscular disease by measuring muscle thickness and echointensity (EI). Reproducibility is limited because of variations in scanning technique and proprietary algorithms that alter EI values. Methods: We developed a standardized scanning protocol and a portable machine without any postimaging processing. Ten subjects underwent scanning of 6 muscles by 3 sonographers on 2 separate days. One of the sonographers repeated the protocol with 4 different machine/transducer combinations. Gray-scale values were measured from each image with the use of a region of interest (ROI) box. Results: Combined intraclass correlation coefficients were 0.92 (intra-rater), 0.88 (inter-rater), and 0.96 (inter-system). The biceps had the highest variability (coefficient of variance [COV] 12.7%), and the medial gastrocnemius had the lowest variability (COV 7.4%). Conclusions: We demonstrate excellent reliability of a reproducible ultrasound system for gray-scale analysis of muscle that has potential applicability as a screening tool for neuromuscular disease.

AB - Introduction: Ultrasound is increasingly used as an adjunct in the diagnosis of neuromuscular disease by measuring muscle thickness and echointensity (EI). Reproducibility is limited because of variations in scanning technique and proprietary algorithms that alter EI values. Methods: We developed a standardized scanning protocol and a portable machine without any postimaging processing. Ten subjects underwent scanning of 6 muscles by 3 sonographers on 2 separate days. One of the sonographers repeated the protocol with 4 different machine/transducer combinations. Gray-scale values were measured from each image with the use of a region of interest (ROI) box. Results: Combined intraclass correlation coefficients were 0.92 (intra-rater), 0.88 (inter-rater), and 0.96 (inter-system). The biceps had the highest variability (coefficient of variance [COV] 12.7%), and the medial gastrocnemius had the lowest variability (COV 7.4%). Conclusions: We demonstrate excellent reliability of a reproducible ultrasound system for gray-scale analysis of muscle that has potential applicability as a screening tool for neuromuscular disease.

KW - Gray-scale analysis

KW - Muscle ultrasound

KW - Neuromuscular disease

KW - Pediatric

KW - Reliability

KW - Screening tool

UR - http://www.scopus.com/inward/record.url?scp=85015191239&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85015191239&partnerID=8YFLogxK

U2 - 10.1002/mus.25513

DO - 10.1002/mus.25513

M3 - Article

C2 - 27977846

AN - SCOPUS:85015191239

JO - Muscle and Nerve

JF - Muscle and Nerve

SN - 0148-639X

ER -