Reducing radiation dose in CT enterography

Andrew J. Del Gaizo, Joel Garland Fletcher, Lifeng Yu, Robert G. Paden, Garrett Clay Spencer, Shuai Leng, Annelise M. Silva, Jeff L. Fidler, Alvin C Silva, Amy K. Hara

Research output: Contribution to journalArticle

32 Citations (Scopus)

Abstract

Computed tomographic (CT) enterography is a diagnostic examination that is increasingly being used to evaluate disorders of the small bowel. An undesirable consequence of CT, however, is patient exposure to ionizing radiation. This is of particular concern with CT enterography because patients tend to be young and require numerous follow-up examinations. There are multiple strategies to reduce radiation dose at CT enterography, including adjusting acquisition parameters, reducing scan length, and reducing tube voltage or tube current. The drawback to dose reduction strategies is degradation of image quality due to increased image noise. However, image noise can be reduced with commercial iterative reconstruction and denoising techniques. With a combination of low-dose techniques and noise-control strategies, one can markedly reduce radiation dose at CT enterography while maintaining diagnostic accuracy.

Original languageEnglish (US)
Pages (from-to)1109-1124
Number of pages16
JournalRadiographics
Volume33
Issue number4
DOIs
StatePublished - Jul 2013

Fingerprint

Radiation
Ionizing Radiation
Noise

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Del Gaizo, A. J., Fletcher, J. G., Yu, L., Paden, R. G., Spencer, G. C., Leng, S., ... Hara, A. K. (2013). Reducing radiation dose in CT enterography. Radiographics, 33(4), 1109-1124. https://doi.org/10.1148/rg.334125074

Reducing radiation dose in CT enterography. / Del Gaizo, Andrew J.; Fletcher, Joel Garland; Yu, Lifeng; Paden, Robert G.; Spencer, Garrett Clay; Leng, Shuai; Silva, Annelise M.; Fidler, Jeff L.; Silva, Alvin C; Hara, Amy K.

In: Radiographics, Vol. 33, No. 4, 07.2013, p. 1109-1124.

Research output: Contribution to journalArticle

Del Gaizo, AJ, Fletcher, JG, Yu, L, Paden, RG, Spencer, GC, Leng, S, Silva, AM, Fidler, JL, Silva, AC & Hara, AK 2013, 'Reducing radiation dose in CT enterography', Radiographics, vol. 33, no. 4, pp. 1109-1124. https://doi.org/10.1148/rg.334125074
Del Gaizo, Andrew J. ; Fletcher, Joel Garland ; Yu, Lifeng ; Paden, Robert G. ; Spencer, Garrett Clay ; Leng, Shuai ; Silva, Annelise M. ; Fidler, Jeff L. ; Silva, Alvin C ; Hara, Amy K. / Reducing radiation dose in CT enterography. In: Radiographics. 2013 ; Vol. 33, No. 4. pp. 1109-1124.
@article{5d8b7a83202d4faeb1ab1d0815c7596c,
title = "Reducing radiation dose in CT enterography",
abstract = "Computed tomographic (CT) enterography is a diagnostic examination that is increasingly being used to evaluate disorders of the small bowel. An undesirable consequence of CT, however, is patient exposure to ionizing radiation. This is of particular concern with CT enterography because patients tend to be young and require numerous follow-up examinations. There are multiple strategies to reduce radiation dose at CT enterography, including adjusting acquisition parameters, reducing scan length, and reducing tube voltage or tube current. The drawback to dose reduction strategies is degradation of image quality due to increased image noise. However, image noise can be reduced with commercial iterative reconstruction and denoising techniques. With a combination of low-dose techniques and noise-control strategies, one can markedly reduce radiation dose at CT enterography while maintaining diagnostic accuracy.",
author = "{Del Gaizo}, {Andrew J.} and Fletcher, {Joel Garland} and Lifeng Yu and Paden, {Robert G.} and Spencer, {Garrett Clay} and Shuai Leng and Silva, {Annelise M.} and Fidler, {Jeff L.} and Silva, {Alvin C} and Hara, {Amy K.}",
year = "2013",
month = "7",
doi = "10.1148/rg.334125074",
language = "English (US)",
volume = "33",
pages = "1109--1124",
journal = "Radiographics",
issn = "0271-5333",
publisher = "Radiological Society of North America Inc.",
number = "4",

}

TY - JOUR

T1 - Reducing radiation dose in CT enterography

AU - Del Gaizo, Andrew J.

AU - Fletcher, Joel Garland

AU - Yu, Lifeng

AU - Paden, Robert G.

AU - Spencer, Garrett Clay

AU - Leng, Shuai

AU - Silva, Annelise M.

AU - Fidler, Jeff L.

AU - Silva, Alvin C

AU - Hara, Amy K.

PY - 2013/7

Y1 - 2013/7

N2 - Computed tomographic (CT) enterography is a diagnostic examination that is increasingly being used to evaluate disorders of the small bowel. An undesirable consequence of CT, however, is patient exposure to ionizing radiation. This is of particular concern with CT enterography because patients tend to be young and require numerous follow-up examinations. There are multiple strategies to reduce radiation dose at CT enterography, including adjusting acquisition parameters, reducing scan length, and reducing tube voltage or tube current. The drawback to dose reduction strategies is degradation of image quality due to increased image noise. However, image noise can be reduced with commercial iterative reconstruction and denoising techniques. With a combination of low-dose techniques and noise-control strategies, one can markedly reduce radiation dose at CT enterography while maintaining diagnostic accuracy.

AB - Computed tomographic (CT) enterography is a diagnostic examination that is increasingly being used to evaluate disorders of the small bowel. An undesirable consequence of CT, however, is patient exposure to ionizing radiation. This is of particular concern with CT enterography because patients tend to be young and require numerous follow-up examinations. There are multiple strategies to reduce radiation dose at CT enterography, including adjusting acquisition parameters, reducing scan length, and reducing tube voltage or tube current. The drawback to dose reduction strategies is degradation of image quality due to increased image noise. However, image noise can be reduced with commercial iterative reconstruction and denoising techniques. With a combination of low-dose techniques and noise-control strategies, one can markedly reduce radiation dose at CT enterography while maintaining diagnostic accuracy.

UR - http://www.scopus.com/inward/record.url?scp=84880075218&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84880075218&partnerID=8YFLogxK

U2 - 10.1148/rg.334125074

DO - 10.1148/rg.334125074

M3 - Article

VL - 33

SP - 1109

EP - 1124

JO - Radiographics

JF - Radiographics

SN - 0271-5333

IS - 4