TY - JOUR
T1 - Rationale and design of the SMall Annuli Randomized To Evolut or SAPIEN Trial (SMART Trial)
AU - Herrmann, Howard C.
AU - Abdel-Wahab, Mohamed
AU - Attizzani, Guilherme F.
AU - Batchelor, Wayne
AU - Bleiziffer, Sabine
AU - Verdoliva, Sarah
AU - Chang, Yanping
AU - Gada, Hemal
AU - Gillam, Linda
AU - Guerrero, Mayra
AU - Mahoney, Paul D.
AU - Petronio, Anna Sonia
AU - Rogers, Toby
AU - Rovin, Joshua
AU - Szerlip, Molly
AU - Whisenant, Brian
AU - Mehran, Roxana
AU - Tchetche, Didier
N1 - Funding Information:
Howard C. Herrmann, MD reports institutional research funding from Abbott, Boston Scientific, Edwards Lifesciences, and Medtronic; consulting fees and speaking honoraria from Edwards Lifesciences and Medtronic. Roxana Mehran, MD reports institutional research grants from Abbott, Abiomed, Biosensors, Boston Scientific, Concept Medical, Medtronic, OrbusNeich; personal fees from ACC, Boston Scientific, Janssen, WebMD, SCAI; consulting fees paid to the institution from Abbott, Abiomed, CeloNova, Concept Medical, Medtronic; Equity <1% in Applied Therapeutics, Elixir Medical, STEL, CONTROLRAD (spouse); Scientific Advisory Board for AMA, Biosensors (spouse). Mohamed Abdel-Wahab, MD reports that his hospital receives speakers’ honoraria and/or consulting fees on his behalf from Boston Scientific, Edwards Lifesciences and Medtronic. Guilherme F. Attizzani, MD reports institutional research funding from Medtronic; Consulting fees and speaking honoraria from Abbott and Medtronic. Wayne Batchelor, MD reports institutional research funding from Abbott and Boston Scientific and consulting fees and speaking honoraria from Medtronic, Abbott and Boston Scientific. Sabine Bleiziffer, MD received speaker honoraria from Medtronic, Edwards Lifesciences and Boston Scientific. Hemal Gada, MD, MBA: Consultant for Medtronic, Boston Scentific, Abbott Vascular. Linda Gillam, MD, MPH directs a core lab with contracts with Edwards Lifesciences, Medtronic and Abbott (no direct compensation) and is an advisor to Bracco, Philips and Edwards Lifesciences. Mayra Guerrero, MD received institutional research grant support from Edwards Lifesciences. Paul D. Mahoney, MD reports institutional research funding from Abbott, Boston Scientific, Edwards Lifesciences, and Medtronic. Consulting fees and proctor fees from Boston Scientific, Medtronic and Edwards. Anna Sonia Petronio, MD reports serving as a consultant for Medtronic, Boston Scientific and Abbott, and receives research funds from Boston Scientific, Medtronic, and GADA. Toby Rogers, MD, reports serving as a consultant and proctor for Medtronic and Edwards Lifesciences, and on an advisory board for Medtronic; and has equity interest in Transmural Systems. Joshua Rovin, MD reports serving as a consultant and proctor for Medtronic and Abbott. Molly Szerlip, MD reports serving as a consultant and proctor for Edwards Life Sciences; speaker and consultant for Boston Scientific; on a steering committee and as a proctor for Abbott; and on a steering committee and as a consultant for Medtronic. Brian Whisenant, MD reports consulting fees from Medtronic and Edwards Lifesciences. Yanping Chang, MS is an employee and shareholder of Medtronic. Sarah Verdoliva, MS is an employee and shareholder of Medtronic. Didier Tchetche, MD serves as a consultant for Medtronic.
Publisher Copyright:
© 2021 Elsevier Inc.
PY - 2022/1
Y1 - 2022/1
N2 - Background: The SMall Annuli Randomized To Evolut or SAPIEN (SMART) Trial was designed to compare the performance of the two most widely available commercial transcatheter aortic valve replacement (TAVR) devices in patients with symptomatic severe native aortic stenosis with a small aortic valve annulus undergoing transfemoral TAVR. Patients with small aortic valve annuli are typically female and are often underrepresented in clinical trials. Methods: The SMART Trial is an international, prospective, multi-center, randomized controlled, post-market trial. The trial will be conducted in approximately 700 subjects at approximately 90 sites globally. Inclusion criteria include severe aortic stenosis, aortic valve annulus area of ≤430 mm2 based on multi-detector computed tomography, and appropriate anatomy for both the Medtronic Evolut PRO/PRO+ self-expanding and Edwards SAPIEN 3/3 Ultra balloon-expandable devices. The primary clinical outcome composite endpoint is defined as mortality, disabling stroke or heart failure rehospitalization at 12 months. The co-primary valve function composite endpoint is defined as bioprosthetic valve dysfunction at 12 months which includes hemodynamic structural valve dysfunction, defined as a mean gradient ≥20 mmHg, non-structural valve dysfunction, defined as severe prothesis-patient mismatch or ≥moderate aortic regurgitation, thrombosis, endocarditis, and aortic valve re-intervention. Powered secondary endpoints will be assessed hierarchically. Conclusions: The SMART trial will be the largest head-to-head comparative trial of transfemoral TAVR using the two most widely available contemporary TAVR devices in the setting of small aortic annuli and the largest trial to enroll primarily women. Clinical trial registration: URL: www.clinicaltrials.gov, Unique identifier: NCT04722250.
AB - Background: The SMall Annuli Randomized To Evolut or SAPIEN (SMART) Trial was designed to compare the performance of the two most widely available commercial transcatheter aortic valve replacement (TAVR) devices in patients with symptomatic severe native aortic stenosis with a small aortic valve annulus undergoing transfemoral TAVR. Patients with small aortic valve annuli are typically female and are often underrepresented in clinical trials. Methods: The SMART Trial is an international, prospective, multi-center, randomized controlled, post-market trial. The trial will be conducted in approximately 700 subjects at approximately 90 sites globally. Inclusion criteria include severe aortic stenosis, aortic valve annulus area of ≤430 mm2 based on multi-detector computed tomography, and appropriate anatomy for both the Medtronic Evolut PRO/PRO+ self-expanding and Edwards SAPIEN 3/3 Ultra balloon-expandable devices. The primary clinical outcome composite endpoint is defined as mortality, disabling stroke or heart failure rehospitalization at 12 months. The co-primary valve function composite endpoint is defined as bioprosthetic valve dysfunction at 12 months which includes hemodynamic structural valve dysfunction, defined as a mean gradient ≥20 mmHg, non-structural valve dysfunction, defined as severe prothesis-patient mismatch or ≥moderate aortic regurgitation, thrombosis, endocarditis, and aortic valve re-intervention. Powered secondary endpoints will be assessed hierarchically. Conclusions: The SMART trial will be the largest head-to-head comparative trial of transfemoral TAVR using the two most widely available contemporary TAVR devices in the setting of small aortic annuli and the largest trial to enroll primarily women. Clinical trial registration: URL: www.clinicaltrials.gov, Unique identifier: NCT04722250.
KW - Aortic stenosis
KW - Prothesis-patient mismatch (PPM)
KW - Randomized trial
KW - Transcatheter aortic valve replacement (TAVR)
UR - http://www.scopus.com/inward/record.url?scp=85122488006&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85122488006&partnerID=8YFLogxK
U2 - 10.1016/j.ahj.2021.09.011
DO - 10.1016/j.ahj.2021.09.011
M3 - Article
C2 - 34587510
AN - SCOPUS:85122488006
SN - 0002-8703
VL - 243
SP - 92
EP - 102
JO - American Heart Journal
JF - American Heart Journal
ER -