Rapid Exclusion of Acute Myocardial Injury and Infarction with a Single High-Sensitivity Cardiac Troponin T in the Emergency Department: A Multicenter United States Evaluation

Yader Sandoval, Bradley R. Lewis, Ramila A. Mehta, Olatunde Ola, Jonathan D. Knott, Laura De Michieli, Ashok Akula, Ronstan Lobo, Eric H. Yang, S. Michael Gharacholou, Marshall Dworak, Erika Crockford, Nicholas Rastas, Eric Grube, Swetha Karturi, Scott Wohlrab, David O. Hodge, Tahir Tak, Charles Cagin, Rajiv GulatiAllan S. Jaffe

Research output: Contribution to journalArticlepeer-review

Abstract

Background: There are good data to support using a single high-sensitivity cardiac troponin T (hs-cTnT) below the limit of detection of 5 ng/L to exclude acute myocardial infarction. Per the US Food and Drug Administration, hs-cTnT can only report to the limit of quantitation of 6 ng/L, a threshold for which there are limited data. Our goal was to determine whether a single hs-cTnT below the limit of quantitation of 6 ng/L is a safe strategy to identify patients at low risk for acute myocardial injury and infarction. Methods: The efficacy (proportion identified as low risk based on baseline hs-cTnT<6 ng/L) of identifying low-risk patients was examined in a multicenter (n=22 sites) US cohort study of emergency department patients undergoing at least 1 hs-cTnT (CV Data Mart Biomarker cohort). We then determined the performance of a single hs-cTnT<6 ng/L (biomarker alone) to exclude acute myocardial injury (subsequent hs-cTnT >99th percentile in those with an initial hs-cTnT<6 ng/L). The clinically intended rule-out strategy combining a nonischemic ECG with a baseline hs-cTnT<6 ng/L was subsequently tested in an adjudicated cohort in which the diagnostic performance for ruling out acute myocardial infarction and safety (myocardial infarction or death at 30 days) were evaluated. Results: A total of 85 610 patients were evaluated in the CV Data Mart Biomarker cohort, among which 24 646 (29%) had a baseline hs-cTnT<6 ng/L. Women were more likely than men to have hs-cTnT<6 ng/L (38% versus 20%, P<0.0001). Among 11 962 patients with baseline hs-cTnT<6 ng/L and serial measurements, only 1.2% developed acute myocardial injury, resulting in a negative predictive value of 98.8% (95% CI, 98.6-99.0) and sensitivity of 99.6% (95% CI, 99.5-99.6). In the adjudicated cohort, a nonischemic ECG with hs-cTnT<6 ng/L identified 33% of patients (610/1849) as low risk and resulted in a negative predictive value and sensitivity of 100% and a 30-day rate of 0.2% for myocardial infarction or death. Conclusions: A single hs-cTnT below the limit of quantitation of 6 ng/L is a safe and rapid method to identify a substantial number of patients at very low risk for acute myocardial injury and infarction.

Original languageEnglish (US)
Pages (from-to)1708-1719
Number of pages12
JournalCirculation
Volume145
Issue number23
DOIs
StatePublished - Jun 7 2022

Keywords

  • myocardial infarction
  • myocardial ischemia
  • troponin T

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Physiology (medical)