TY - JOUR
T1 - Radiographic cup anteversion measurement corrected from pelvic tilt
AU - Wang, Liao
AU - Thoreson, Andrew R.
AU - Trousdale, Robert T.
AU - Morrey, Bernard F.
AU - Dai, Kerong
AU - An, Kai Nan
N1 - Funding Information:
One author (LW) gratefully acknowledges the support of the National Natural Science Foundation of China (Grant no. 81201412 ), the Science and Technology Commission of Shanghai Municipality ( 16441908700 ), and Shanghai Jiao Tong University ( YG2016MS11 , jyyq201516 ).
Publisher Copyright:
© 2017 IPEM
PY - 2017/11
Y1 - 2017/11
N2 - The purpose of this study was to develop a novel technique to improve the accuracy of radiographic cup anteversion measurement by correcting the influence of pelvic tilt. Ninety virtual total hip arthroplasties were simulated from computed tomography data of 6 patients with 15 predetermined cup orientations. For each simulated implantation, anteroposterior (AP) virtual pelvic radiographs were generated for 11 predetermined pelvic tilts. A linear regression model was created to capture the relationship between radiographic cup anteversion angle error measured on AP pelvic radiographs and pelvic tilt. Overall, nine hundred and ninety virtual AP pelvic radiographs were measured, and 90 linear regression models were created. Pearson's correlation analyses confirmed a strong correlation between the errors of conventional radiographic cup anteversion angle measured on AP pelvic radiographs and the magnitude of pelvic tilt (P < 0.001). The mean of 90 slopes and y-intercepts of the regression lines were −0.8 and −2.5° which were applied as the general correction parameters for the proposed tool to correct conventional cup anteversion angle from the influence of pelvic tilt. The current method proposes to measure the pelvic tilt on a lateral radiograph, and to use it as a correction for the radiographic cup anteversion measurement on an AP pelvic radiograph. Thus, both AP and lateral pelvic radiographs are required for the measurement of pelvic posture-integrated cup anteversion. Compared with conventional radiographic cup anteversion, the errors of pelvic posture-integrated radiographic cup anteversion were reduced from 10.03 (SD = 5.13) degrees to 2.53 (SD = 1.33) degrees. Pelvic posture-integrated cup anteversion measurement improves the accuracy of radiographic cup anteversion measurement, which shows the potential of further clarifying the etiology of postoperative instability based on planar radiographs.
AB - The purpose of this study was to develop a novel technique to improve the accuracy of radiographic cup anteversion measurement by correcting the influence of pelvic tilt. Ninety virtual total hip arthroplasties were simulated from computed tomography data of 6 patients with 15 predetermined cup orientations. For each simulated implantation, anteroposterior (AP) virtual pelvic radiographs were generated for 11 predetermined pelvic tilts. A linear regression model was created to capture the relationship between radiographic cup anteversion angle error measured on AP pelvic radiographs and pelvic tilt. Overall, nine hundred and ninety virtual AP pelvic radiographs were measured, and 90 linear regression models were created. Pearson's correlation analyses confirmed a strong correlation between the errors of conventional radiographic cup anteversion angle measured on AP pelvic radiographs and the magnitude of pelvic tilt (P < 0.001). The mean of 90 slopes and y-intercepts of the regression lines were −0.8 and −2.5° which were applied as the general correction parameters for the proposed tool to correct conventional cup anteversion angle from the influence of pelvic tilt. The current method proposes to measure the pelvic tilt on a lateral radiograph, and to use it as a correction for the radiographic cup anteversion measurement on an AP pelvic radiograph. Thus, both AP and lateral pelvic radiographs are required for the measurement of pelvic posture-integrated cup anteversion. Compared with conventional radiographic cup anteversion, the errors of pelvic posture-integrated radiographic cup anteversion were reduced from 10.03 (SD = 5.13) degrees to 2.53 (SD = 1.33) degrees. Pelvic posture-integrated cup anteversion measurement improves the accuracy of radiographic cup anteversion measurement, which shows the potential of further clarifying the etiology of postoperative instability based on planar radiographs.
KW - Digitally reconstructed radiograph
KW - Pelvic tilt
KW - Radiographic cup anteversion
KW - Total hip arthroplasty
UR - http://www.scopus.com/inward/record.url?scp=85028744845&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85028744845&partnerID=8YFLogxK
U2 - 10.1016/j.medengphy.2017.08.008
DO - 10.1016/j.medengphy.2017.08.008
M3 - Article
C2 - 28888787
AN - SCOPUS:85028744845
SN - 1350-4533
VL - 49
SP - 103
EP - 108
JO - Journal of Biomedical Engineering
JF - Journal of Biomedical Engineering
ER -