Radiation dose incurred in the exclusion of vascular filling in transforaminal epidural steroid injections: Fluoroscopy, digital subtraction angiography, and ct/fluoroscopy

Timothy Maus, Beth A. Schueler, Shuai Leng, Dayne Magnuson, Dixon J. Magnuson, Felix E. Diehn

Research output: Contribution to journalArticle

9 Citations (Scopus)

Abstract

Objective: This study seeks to measure the radiation dose incurred in the evaluation of vascular filling during transforaminal epidural steroid injections (TFESI) using conventional fluoroscopy (CF), digital subtraction angiography (DSA), and multislice, pulsed computed tomography fluoroscopy (CT/F). Methods: Three portable C-arms and a fixed multipurpose C-arm were evaluated. The radiation dose rate was measured using an anthropomorphic phantom during CF and DSA in anterior-posterior positions for cervical and lumbar TFESIs. Effective doses were calculated for 5-second exposures. The effective doses incurred in the cervical and lumbar spine during two CT/F exposures were calculated based on the reported volume CT dose index and dose length product. Results: DSA imaging increased the effective dose incurred over CF with portable C-arms (medium dose rate) by 2.5-4.3 fold for cervical TFESI and 2.3-4.2 fold for lumbar TFESI. The incremental dose incurred with DSA ranged from 4.0 to 7.7μSv in the cervical region and from 22-38μSv in the lumbar spine. CT/F increased the incurred dose 19-fold in the cervical region and 8.0-fold in the lumbar region (incremental doses 49μSv and 140μSv, respectively) relative to CF. Conclusion: The use of DSA imaging to exclude vascular uptake during TFESI increases radiation dose over CF. CT/F incurs additional dose beyond most DSA. Minimizing radiation dose by limiting DSA and CT/F use to spine segments or clinical situations involving higher risk may be desirable. However, the incremental radiation doses incurred by DSA or CT/F are of such low magnitude that health risks cannot currently be estimated.

Original languageEnglish (US)
Pages (from-to)1328-1333
Number of pages6
JournalPain Medicine (United States)
Volume15
Issue number8
DOIs
StatePublished - 2014

Fingerprint

Epidural Injections
Digital Subtraction Angiography
Fluoroscopy
Blood Vessels
Steroids
Radiation
Tomography
Spine
Arm
Lumbosacral Region
Cone-Beam Computed Tomography
Multidetector Computed Tomography

Keywords

  • Epidural (injection space)
  • Fluoroscopy
  • Radiculopathy
  • Safety
  • Steroids

ASJC Scopus subject areas

  • Clinical Neurology
  • Anesthesiology and Pain Medicine

Cite this

Radiation dose incurred in the exclusion of vascular filling in transforaminal epidural steroid injections : Fluoroscopy, digital subtraction angiography, and ct/fluoroscopy. / Maus, Timothy; Schueler, Beth A.; Leng, Shuai; Magnuson, Dayne; Magnuson, Dixon J.; Diehn, Felix E.

In: Pain Medicine (United States), Vol. 15, No. 8, 2014, p. 1328-1333.

Research output: Contribution to journalArticle

@article{63aad24806f54eb6a05941ad4bc63c9c,
title = "Radiation dose incurred in the exclusion of vascular filling in transforaminal epidural steroid injections: Fluoroscopy, digital subtraction angiography, and ct/fluoroscopy",
abstract = "Objective: This study seeks to measure the radiation dose incurred in the evaluation of vascular filling during transforaminal epidural steroid injections (TFESI) using conventional fluoroscopy (CF), digital subtraction angiography (DSA), and multislice, pulsed computed tomography fluoroscopy (CT/F). Methods: Three portable C-arms and a fixed multipurpose C-arm were evaluated. The radiation dose rate was measured using an anthropomorphic phantom during CF and DSA in anterior-posterior positions for cervical and lumbar TFESIs. Effective doses were calculated for 5-second exposures. The effective doses incurred in the cervical and lumbar spine during two CT/F exposures were calculated based on the reported volume CT dose index and dose length product. Results: DSA imaging increased the effective dose incurred over CF with portable C-arms (medium dose rate) by 2.5-4.3 fold for cervical TFESI and 2.3-4.2 fold for lumbar TFESI. The incremental dose incurred with DSA ranged from 4.0 to 7.7μSv in the cervical region and from 22-38μSv in the lumbar spine. CT/F increased the incurred dose 19-fold in the cervical region and 8.0-fold in the lumbar region (incremental doses 49μSv and 140μSv, respectively) relative to CF. Conclusion: The use of DSA imaging to exclude vascular uptake during TFESI increases radiation dose over CF. CT/F incurs additional dose beyond most DSA. Minimizing radiation dose by limiting DSA and CT/F use to spine segments or clinical situations involving higher risk may be desirable. However, the incremental radiation doses incurred by DSA or CT/F are of such low magnitude that health risks cannot currently be estimated.",
keywords = "Epidural (injection space), Fluoroscopy, Radiculopathy, Safety, Steroids",
author = "Timothy Maus and Schueler, {Beth A.} and Shuai Leng and Dayne Magnuson and Magnuson, {Dixon J.} and Diehn, {Felix E.}",
year = "2014",
doi = "10.1111/pme.12455",
language = "English (US)",
volume = "15",
pages = "1328--1333",
journal = "Pain Medicine",
issn = "1526-2375",
publisher = "Wiley-Blackwell",
number = "8",

}

TY - JOUR

T1 - Radiation dose incurred in the exclusion of vascular filling in transforaminal epidural steroid injections

T2 - Fluoroscopy, digital subtraction angiography, and ct/fluoroscopy

AU - Maus, Timothy

AU - Schueler, Beth A.

AU - Leng, Shuai

AU - Magnuson, Dayne

AU - Magnuson, Dixon J.

AU - Diehn, Felix E.

PY - 2014

Y1 - 2014

N2 - Objective: This study seeks to measure the radiation dose incurred in the evaluation of vascular filling during transforaminal epidural steroid injections (TFESI) using conventional fluoroscopy (CF), digital subtraction angiography (DSA), and multislice, pulsed computed tomography fluoroscopy (CT/F). Methods: Three portable C-arms and a fixed multipurpose C-arm were evaluated. The radiation dose rate was measured using an anthropomorphic phantom during CF and DSA in anterior-posterior positions for cervical and lumbar TFESIs. Effective doses were calculated for 5-second exposures. The effective doses incurred in the cervical and lumbar spine during two CT/F exposures were calculated based on the reported volume CT dose index and dose length product. Results: DSA imaging increased the effective dose incurred over CF with portable C-arms (medium dose rate) by 2.5-4.3 fold for cervical TFESI and 2.3-4.2 fold for lumbar TFESI. The incremental dose incurred with DSA ranged from 4.0 to 7.7μSv in the cervical region and from 22-38μSv in the lumbar spine. CT/F increased the incurred dose 19-fold in the cervical region and 8.0-fold in the lumbar region (incremental doses 49μSv and 140μSv, respectively) relative to CF. Conclusion: The use of DSA imaging to exclude vascular uptake during TFESI increases radiation dose over CF. CT/F incurs additional dose beyond most DSA. Minimizing radiation dose by limiting DSA and CT/F use to spine segments or clinical situations involving higher risk may be desirable. However, the incremental radiation doses incurred by DSA or CT/F are of such low magnitude that health risks cannot currently be estimated.

AB - Objective: This study seeks to measure the radiation dose incurred in the evaluation of vascular filling during transforaminal epidural steroid injections (TFESI) using conventional fluoroscopy (CF), digital subtraction angiography (DSA), and multislice, pulsed computed tomography fluoroscopy (CT/F). Methods: Three portable C-arms and a fixed multipurpose C-arm were evaluated. The radiation dose rate was measured using an anthropomorphic phantom during CF and DSA in anterior-posterior positions for cervical and lumbar TFESIs. Effective doses were calculated for 5-second exposures. The effective doses incurred in the cervical and lumbar spine during two CT/F exposures were calculated based on the reported volume CT dose index and dose length product. Results: DSA imaging increased the effective dose incurred over CF with portable C-arms (medium dose rate) by 2.5-4.3 fold for cervical TFESI and 2.3-4.2 fold for lumbar TFESI. The incremental dose incurred with DSA ranged from 4.0 to 7.7μSv in the cervical region and from 22-38μSv in the lumbar spine. CT/F increased the incurred dose 19-fold in the cervical region and 8.0-fold in the lumbar region (incremental doses 49μSv and 140μSv, respectively) relative to CF. Conclusion: The use of DSA imaging to exclude vascular uptake during TFESI increases radiation dose over CF. CT/F incurs additional dose beyond most DSA. Minimizing radiation dose by limiting DSA and CT/F use to spine segments or clinical situations involving higher risk may be desirable. However, the incremental radiation doses incurred by DSA or CT/F are of such low magnitude that health risks cannot currently be estimated.

KW - Epidural (injection space)

KW - Fluoroscopy

KW - Radiculopathy

KW - Safety

KW - Steroids

UR - http://www.scopus.com/inward/record.url?scp=84906058088&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84906058088&partnerID=8YFLogxK

U2 - 10.1111/pme.12455

DO - 10.1111/pme.12455

M3 - Article

C2 - 24961152

AN - SCOPUS:84906058088

VL - 15

SP - 1328

EP - 1333

JO - Pain Medicine

JF - Pain Medicine

SN - 1526-2375

IS - 8

ER -